Cost comparison of advanced oxidation processes for wastewater treatment using accumulated oxygen-equivalent criteria
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Advanced oxidation processes (AOPs) have received a lot of attention over the years as advanced physico-chemical polishing wastewater treatments to remove biorefractory pollutants. Additionally, many studies report their excellent degradation and mineralization performance as stand-alone technologies too, demonstrating the versatility of these processes; however, there is a lack of suitable methods to compare the performance (in terms of removal efficiency and operating costs) of different AOPs in the same conditions. In this context, the goal of this paper is to propose a systematic investigation by introducing a novel criterion, namely the accumulated oxygen-equivalent chemical-oxidation dose (AOCD), to systematically compare the diverse AOPs available: ozonation, H2O2 photolysis, Fenton, photo-Fenton, electro-Fenton and photoelectro-Fenton (paired with anodic oxidation, for the latter two). For each of these, the cost efficiency was determined by optimizing the operating conditions for the removal of phenol, selected as a model pollutant (1.4 mM, equivalent to 100 mg-C L-1). The operating costs considered sludge management, chemical use and electricity consumption. Among all AOPs, electro-Fenton was the most cost-effective (108 - 125 € m-3), notwithstanding the mineralization target (50%, 75% and 99%), owing to its electrocatalytic behavior. Chemical Fenton proved competitive too up to 50% of mineralization, meaning that it could also be considered as a cost-effective pre-treatment solution. AOCD was the lowest for electro-Fenton, which could be attributed to its excellent faradaic yield, while UV-based processes generally required the highest dose. The AOCD criterion could serve as a baseline for AOP comparison and prove useful for the legislator to determine the "best available techniques" as defined by the Industrial Emissions European Union Directive 2010/75/EU.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buxton, G. V., Greenstock, C. L., Helman, W. P., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555805 · Cited by 12,332 · cited 1×
“For all AOPs, the main oxidant - produced in mild conditions (Buxton et al., 1988) - is the hydroxyl radical (OH), the strongest oxidizing agent (E (OH/H2O) = 2.”
BackgroundElectro-Fenton Process and Related Electrochemical Technologies Based on Fenton’s Reaction Chemistry
Brillas, E., Sirés, I., & Oturan, M. A. (2009) · Chemical Reviews · doi:10.1021/cr900136g · Cited by 3,437 · cited 3×
“Photoelectro-Fenton Similarly as for chemical Fenton, UV-light was added to electro-Fenton to boost the production of OH (Brillas et al., 2009; Sun and Pignatello, 1993) and the regeneration of Fe (Ruppert et al.”
BackgroundEvaluation of advanced oxidation processes for water and wastewater treatment – A critical review
Miklos, D. B., Remy, C., Jekel, M., Linden, K. G., Drewes, J. E., & Hübner, U. (2018) · Water Research · doi:10.1016/j.watres.2018.03.042 · Cited by 3,050 · cited 1×
“EAOPs offer the benefits to operate with minimal addition of chemicals; yet, there is a lack of systematic studies comparing the costs of various AOPs under the same conditions and for the same application (Huddersman et al., 2019; Miklos et al., 2018).”
BackgroundOller, I., Malato, S., & Sánchez-Pérez, J. A. (2011) · Science of The Total Environment · doi:10.1016/j.scitotenv.2010.08.061 · Cited by 2,406 · cited 1×
“Their combination with a biological treatment to remove the biodegradable fraction is particularly encouraged when possible, to decrease the global cost of the treatment (Mousset et al., 2018c; Mousset et al., 2021; Oller et al., 2011; Olvera-Vargas et al., 2016; Rizzo et al., 2020).”
BackgroundDirect And Mediated Anodic Oxidation of Organic Pollutants
Panizza, M., & Cerisola, G. (2009) · Chemical Reviews · doi:10.1021/cr9001319 · Cited by 2,346 · cited 4×
“Higher current densities favored the oxygen evolution reaction over the production of OH (Panizza and Cerisola, 2009).”
BackgroundInfluentialAdvanced Oxidation Processes in Water/Wastewater Treatment: Principles and Applications. A Review
Oturan, M. A., & Aaron, J.-J. (2014) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2013.829765 · Cited by 2,272
Moreira, F. C., Boaventura, R. A. R., Brillas, E., & Vilar, V. J. P. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2016.08.037 · Cited by 2,144
Electrochemical Advanced Oxidation Processes: Today and Tomorrow. A Review
Sirés, I., Brillas, E., Oturan, M. A., Rodrigo, M. A., & Panizza, M. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-2783-1 · Cited by 1,943
Martínez-Huitle, C. A., Rodrigo, M. A., Sirés, I., & Scialdone, O. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00361 · Cited by 1,633
Bolton, J. R., Bircher, K. G., Tumas, W., & Tolman, C. A. (2001) · Pure and Applied Chemistry · doi:10.1351/pac200173040627 · Cited by 1,157
Cited by
Saravanan, A., Deivayanai, V. C., Kumar, P. S., Rangasamy, G., Hemavathy, R. V., Harshana, T., Gayathri, N., & Alagumalai, K. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2022.136524 · Cited by 600
ADVANCED OXIDATION PROCESS: A remediation technique for organic and non-biodegradable pollutant
Kumari, P., & Kumar, A. (2023) · Results in Surfaces and Interfaces · doi:10.1016/j.rsurfi.2023.100122 · Cited by 314
Recent advances in electro-Fenton process and its emerging applications
Nidheesh, P. V., Ganiyu, S. O., Martínez-Huitle, C. A., Mousset, E., Olvera-Vargas, H., Trellu, C., Zhou, M., & Oturan, M. A. (2023) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2022.2093074 · Cited by 197
“A recent study highlighted the cost effectiveness (considering operating costs such as sludge management, chemical use and electricity consumption) of EF process compared to ozonation, H2O2 photolysis, Fenton and photo-Fenton at laboratory scale (Mousset et al., 2021).”
BackgroundMethodSelf-citationSatyam, S., & Patra, S. (2025) · Processes · doi:10.3390/pr13040987 · Cited by 170
“TiO is active primarily under UV-A light, which constitutes only a small portion of the solar spectrum, thereby limiting its energy efficiency.”
Microplastic removal and management strategies for wastewater treatment plants
Ahmed, S. F., Islam, N., Tasannum, N., Mehjabin, A., Momtahin, A., Chowdhury, A. A., Almomani, F., & Mofijur, M. (2024) · Chemosphere · doi:10.1016/j.chemosphere.2023.140648 · Cited by 161
Metadata
- Authors
- Mousset, E., Loh, W. H., Lim, W. S., Jarry, L., Wang, Z., & Lefebvre, O.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 200
- Pages
- 117234
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W3161879235
- Cited by
- 192
- References
- 65
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.