Cost comparison of advanced oxidation processes for wastewater treatment using accumulated oxygen-equivalent criteria
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Advanced oxidation processes (AOPs) have received a lot of attention over the years as advanced physico-chemical polishing wastewater treatments to remove biorefractory pollutants. Additionally, many studies report their excellent degradation and mineralization performance as stand-alone technologies too, demonstrating the versatility of these processes; however, there is a lack of suitable methods to compare the performance (in terms of removal efficiency and operating costs) of different AOPs in the same conditions. In this context, the goal of this paper is to propose a systematic investigation by introducing a novel criterion, namely the accumulated oxygen-equivalent chemical-oxidation dose (AOCD), to systematically compare the diverse AOPs available: ozonation, H2O2 photolysis, Fenton, photo-Fenton, electro-Fenton and photoelectro-Fenton (paired with anodic oxidation, for the latter two). For each of these, the cost efficiency was determined by optimizing the operating conditions for the removal of phenol, selected as a model pollutant (1.4 mM, equivalent to 100 mg-C L-1). The operating costs considered sludge management, chemical use and electricity consumption. Among all AOPs, electro-Fenton was the most cost-effective (108 - 125 € m-3), notwithstanding the mineralization target (50%, 75% and 99%), owing to its electrocatalytic behavior. Chemical Fenton proved competitive too up to 50% of mineralization, meaning that it could also be considered as a cost-effective pre-treatment solution. AOCD was the lowest for electro-Fenton, which could be attributed to its excellent faradaic yield, while UV-based processes generally required the highest dose. The AOCD criterion could serve as a baseline for AOP comparison and prove useful for the legislator to determine the "best available techniques" as defined by the Industrial Emissions European Union Directive 2010/75/EU.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buxton, G. V., Greenstock, C. L., Helman, W. P., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555805 · Cited by 12,332 · cited 1×
“For all AOPs, the main oxidant - produced in mild conditions (Buxton et al., 1988) - is the hydroxyl radical (OH), the strongest oxidizing agent (E (OH/H2O) = 2.”
BackgroundElectro-Fenton Process and Related Electrochemical Technologies Based on Fenton’s Reaction Chemistry
Brillas, E., Sirés, I., & Oturan, M. A. (2009) · Chemical Reviews · doi:10.1021/cr900136g · Cited by 3,437 · cited 3×
“Photoelectro-Fenton Similarly as for chemical Fenton, UV-light was added to electro-Fenton to boost the production of OH (Brillas et al., 2009; Sun and Pignatello, 1993) and the regeneration of Fe (Ruppert et al.”
BackgroundEvaluation of advanced oxidation processes for water and wastewater treatment – A critical review
Miklos, D. B., Remy, C., Jekel, M., Linden, K. G., Drewes, J. E., & Hübner, U. (2018) · Water Research · doi:10.1016/j.watres.2018.03.042 · Cited by 3,050 · cited 1×
“EAOPs offer the benefits to operate with minimal addition of chemicals; yet, there is a lack of systematic studies comparing the costs of various AOPs under the same conditions and for the same application (Huddersman et al., 2019; Miklos et al., 2018).”
BackgroundOller, I., Malato, S., & Sánchez-Pérez, J. A. (2011) · Science of The Total Environment · doi:10.1016/j.scitotenv.2010.08.061 · Cited by 2,406 · cited 1×
“Their combination with a biological treatment to remove the biodegradable fraction is particularly encouraged when possible, to decrease the global cost of the treatment (Mousset et al., 2018c; Mousset et al., 2021; Oller et al., 2011; Olvera-Vargas et al., 2016; Rizzo et al., 2020).”
BackgroundDirect And Mediated Anodic Oxidation of Organic Pollutants
Panizza, M., & Cerisola, G. (2009) · Chemical Reviews · doi:10.1021/cr9001319 · Cited by 2,346 · cited 4×
“Higher current densities favored the oxygen evolution reaction over the production of OH (Panizza and Cerisola, 2009).”
BackgroundInfluentialAdvanced Oxidation Processes in Water/Wastewater Treatment: Principles and Applications. A Review
Oturan, M. A., & Aaron, J.-J. (2014) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2013.829765 · Cited by 2,272
Moreira, F. C., Boaventura, R. A. R., Brillas, E., & Vilar, V. J. P. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2016.08.037 · Cited by 2,144
Electrochemical Advanced Oxidation Processes: Today and Tomorrow. A Review
Sirés, I., Brillas, E., Oturan, M. A., Rodrigo, M. A., & Panizza, M. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-2783-1 · Cited by 1,943
Martínez-Huitle, C. A., Rodrigo, M. A., Sirés, I., & Scialdone, O. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00361 · Cited by 1,633
Bolton, J. R., Bircher, K. G., Tumas, W., & Tolman, C. A. (2001) · Pure and Applied Chemistry · doi:10.1351/pac200173040627 · Cited by 1,157
Ganiyu, S. O., Zhou, M., & Martínez-Huitle, C. A. (2018) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2018.04.044 · Cited by 905
Heterogeneous Photocatalytic Decomposition of Phenol over TiO2 Powder
Okamoto, K.-I., Yamamoto, Y., Tanaka, H., Tanaka, M., & Itaya, A. (1985) · Bulletin of the Chemical Society of Japan · doi:10.1246/bcsj.58.2015 · Cited by 728 · cited 2×
“12 for phenol (Okamoto et al., 1985)), resulted in increasing costs to reach higher mineralization targets.”
BackgroundChen, R., & Pignatello, J. J. (1997) · Environmental Science & Technology · doi:10.1021/es9610646 · Cited by 676 · cited 1×
“An excess of H2O2 can generate the less reactive hydroperoxy-radicals, known to inhibit the oxidation process (Chen and Pignatello, 1997), while an excess of Fe favors secondary reactions that limit the OH production rate (Brillas et al.”
BackgroundSun, Y., & Pignatello, J. J. (1993) · Environmental Science & Technology · doi:10.1021/es00039a010 · Cited by 616 · cited 1×
“Photoelectro-Fenton Similarly as for chemical Fenton, UV-light was added to electro-Fenton to boost the production of OH (Brillas et al., 2009; Sun and Pignatello, 1993) and the regeneration of Fe (Ruppert et al.”
BackgroundWang, W., Serp, P., Kalck, P., & Faria, J. L. (2005) · Journal of Molecular Catalysis A: Chemical · doi:10.1016/j.molcata.2005.02.027 · Cited by 521 · cited 1×
“For the purpose of benchmarking processes against one another and also against the literature, phenol was selected as a model organic pollutant, being widely studied in AOP research (Azevedo et al., 2009; Bremner et al., 2006; Brillas and GarciaSegura, 2020; Maciel et al., 2004; Mousset et al., 2016a; Mousset et al.,…”
MethodAnodic oxidation of 2-naphthol at boron-doped diamond electrodes
Panizza, M., Michaud, P. A., Cerisola, G., & Comninellis, C. (2001) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(01)00398-9 · Cited by 491 · cited 1×
“For every concentration, the mineralization followed a linear trend because the electro-oxidation reaction of organic compounds at the BDD surface was the rate-limiting step instead of mass transfer limitations (Mousset et al., 2019; Panizza et al., 2001).”
BackgroundPimentel, M., Oturan, N., Dezotti, M., & Oturan, M. A. (2008) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2008.02.011 · Cited by 438 · cited 1×
“For the purpose of benchmarking processes against one another and also against the literature, phenol was selected as a model organic pollutant, being widely studied in AOP research (Azevedo et al., 2009; Bremner et al., 2006; Brillas and GarciaSegura, 2020; Maciel et al., 2004; Mousset et al., 2016a; Mousset et al.,…”
MethodCañizares, P., Paz, R., Sáez, C., & Rodrigo, M. A. (2009) · Journal of Environmental Management · doi:10.1016/j.jenvman.2007.10.010 · Cited by 422 · cited 7×
“Still, it is important to note that the volume of sludge represented around 15% of the treated wastewater in the Fenton process applied in a previous study (Cañizares et al., 2009), which would result in non-negligible sludge management costs.”
BackgroundMethodResultInfluentialBrillas, E., & Garcia-Segura, S. (2020) · Separation and Purification Technology · doi:10.1016/j.seppur.2019.116337 · Cited by 394
Evidence for an Additional Oxidant in the Photoassisted Fenton Reaction
Pignatello, J. J., Liu, D., & Huston, P. (1999) · Environmental Science & Technology · doi:10.1021/es980969b · Cited by 390
The photo-Fenton reaction — an effective photochemical wastewater treatment process
Ruppert, G., Bauer, R., & Heisler, G. (1993) · Journal of Photochemistry and Photobiology A: Chemistry · doi:10.1016/1010-6030(93)80035-8 · Cited by 362 · cited 2×
“, 2009; Sun and Pignatello, 1993) and the regeneration of Fe (Ruppert et al., 1993).”
BackgroundLucas, M. S., Peres, J. A., & Li Puma, G. (2010) · Separation and Purification Technology · doi:10.1016/j.seppur.2010.01.016 · Cited by 354 · cited 2×
“, 2013), while specific energy (kWh m g-TOC) that includes removal efficiency was considered instead in another work (Lucas et al., 2010).”
BackgroundGuideline for Measurement of Ozone Concentration in the Process Gas From an Ozone Generator
Rakness, K., Gordon, G., Langlais, B., Masschelein, W., Matsumoto, N., Richard, Y., Robson, C. M., & Somiya, I. (1996) · Ozone: Science & Engineering · doi:10.1080/01919519608547327 · Cited by 339 · cited 1×
“The actual ozone output from the ozone generator was determined using the potassium iodide (KI) wet-chemistry method (Rakness et al., 1996).”
MethodRizzo, L., Gernjak, W., Krzeminski, P., Malato, S., McArdell, C. S., Perez, J. A. S., Schaar, H., & Fatta-Kassinos, D. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2019.136312 · Cited by 308 · cited 6×
“A new criterion to enable systematic AOP cost-performance comparison: the accumulated oxygen-equivalent chemical-oxidation dose (AOCD) The need to develop criteria for suitable comparison between AOPs is important for evaluating the best available technologies as defined by the European Commission (Rizzo et al., 2020).”
BackgroundInfluentialPrieto-Rodríguez, L., Oller, I., Klamerth, N., Agüera, A., Rodríguez, E. M., & Malato, S. (2013) · Water Research · doi:10.1016/j.watres.2012.11.002 · Cited by 306
Benkelberg, H.-J., & Warneck, P. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100014a049 · Cited by 300
Phenol degradation using hydroxyl radicals generated from zero-valent iron and hydrogen peroxide
Bremner, D. H., Burgess, A. E., Houllemare, D., & Namkung, K.-C. (2005) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2005.09.005 · Cited by 286 · cited 1×
“For the purpose of benchmarking processes against one another and also against the literature, phenol was selected as a model organic pollutant, being widely studied in AOP research (Azevedo et al., 2009; Bremner et al., 2006; Brillas and GarciaSegura, 2020; Maciel et al., 2004; Mousset et al., 2016a; Mousset et al.,…”
MethodOzonolysis of phenols in aqueous solution
Mvula, E., & von Sonntag, C. (2003) · Organic & Biomolecular Chemistry · doi:10.1039/b301824p · Cited by 274
Sychev, A. Y., & Isak, V. G. (1995) · Russian Chemical Reviews · doi:10.1070/rc1995v064n12abeh000195 · Cited by 198
Nidheesh, P. V., Divyapriya, G., Oturan, N., Trellu, C., & Oturan, M. A. (2019) · ChemElectroChem · doi:10.1002/celc.201801876 · Cited by 184
Biodegradation of organic pollutants in saline wastewater by halophilic microorganisms: a review
Castillo-Carvajal, L. C., Sanz-Martín, J. L., & Barragán-Huerta, B. E. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-3036-z · Cited by 184 · cited 1×
“OH radicals are extremely reactive species that attack most organic molecules with rate constants in the range of 10(8) – 10(10) L mol s towards double carbon bonds, such as aromatic compounds, which constitute the bulk of industrial organic pollutants (Brillas et al., 2009; Castillo-Carvajal et al., 2014; Saien and S…”
BackgroundYao, W., Ur Rehman, S. W., Wang, H., Yang, H., Yu, G., & Wang, Y. (2018) · Water Research · doi:10.1016/j.watres.2018.03.044 · Cited by 179
Lee, Y., Gerrity, D., Lee, M., Gamage, S., Pisarenko, A., Trenholm, R. A., Canonica, S., Snyder, S. A., & von Gunten, U. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.5b04904 · Cited by 178
Goi, A., & Trapido, M. (2002) · Chemosphere · doi:10.1016/s0045-6535(01)00203-x · Cited by 177
Mousset, E., Frunzo, L., Esposito, G., Hullebusch, E. D. V., Oturan, N., & Oturan, M. A. (2016) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2015.06.014 · Cited by 169
Self-citationGarcía-Rodríguez, O., Mousset, E., Olvera‐Vargas, H., & Lefebvre, O. (2020) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2020.1820428 · Cited by 163 · cited 1×
“4 continuously generate OH in situ through different modes of action depending upon the electrode materials (Garcia-Rodriguez et al., 2020; Moreira et al., 2017).”
BackgroundSelf-citationPhenol removal from high salinity effluents using Fenton’s reagent and photo-Fenton reactions
Maciel, R., Sant’Anna, G. L., & Dezotti, M. (2004) · Chemosphere · doi:10.1016/j.chemosphere.2004.07.032 · Cited by 160 · cited 1×
“For the purpose of benchmarking processes against one another and also against the literature, phenol was selected as a model organic pollutant, being widely studied in AOP research (Azevedo et al., 2009; Bremner et al., 2006; Brillas and GarciaSegura, 2020; Maciel et al., 2004; Mousset et al., 2016a; Mousset et al.,…”
MethodComparison of photocatalytic space-time yields of 12 reactor designs for wastewater treatment
Leblebici, M. E., Stefanidis, G. D., & Gerven, T. V. (2015) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2015.09.009 · Cited by 149 · cited 2×
“Another commonly-used parameter is the space-time yield with the advantage to consider the residence time, removal efficiency (including apparent rate constant) and the ideal reactor design such as continuously stirred tank reactor (CSTR) and plug-flow reactor (PFR) (Leblebici et al., 2015).”
BackgroundMineralization of herbicide mecoprop by photoelectro-Fenton with UVA and solar light
Flox, C., Garrido, J., Rodríguez, R., Cabot, P., Centellas, F., Arias, C., & Brillas, E. (2007) · Catalysis Today · doi:10.1016/j.cattod.2007.06.049 · Cited by 147 · cited 1×
“This shows the importance to study the potential of solar irradiation instead of artificial UV light to increase the competitiveness of photo-processes (Flox et al., 2007).”
BackgroundAdvanced Oxidation Processes for the Treatment of Biorecalcitrant Organics in Wastewater
Ghatak, H. R. (2013) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2013.763581 · Cited by 144
Sgroi, M., Snyder, S. A., & Roccaro, P. (2020) · Chemosphere · doi:10.1016/j.chemosphere.2020.128527 · Cited by 143
Optimal methods for quenching H2O2 residuals prior to UFC testing
Liu, W., Andrews, S., Stefan, M. I., & Bolton, J. R. (2003) · Water Research · doi:10.1016/s0043-1354(03)00264-1 · Cited by 143 · cited 1×
“H2O2 quenching before analysis was done using a solution of Na2S2O3 at a ratio of two moles of Na2S2O3 per mole of H2O2 (Liu et al., 2003).”
MethodMousset, E., Oturan, N., & Oturan, M. A. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2017.12.028 · Cited by 120
Self-citationOlvera‐Vargas, H., Cocerva, T., Oturan, N., Buisson, D., & Oturan, M. A. (2015) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.12.010 · Cited by 111 · cited 1×
“Their combination with a biological treatment to remove the biodegradable fraction is particularly encouraged when possible, to decrease the global cost of the treatment (Mousset et al., 2018c; Mousset et al., 2021; Oller et al., 2011; Olvera-Vargas et al., 2016; Rizzo et al., 2020).”
BackgroundMousset, E., Wang, Z., Hammaker, J., & Lefebvre, O. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.08.002 · Cited by 111
Self-citationBergmann, M. E. H., Koparal, A. S., & Iourtchouk, T. (2014) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2012.718948 · Cited by 107
Mousset, E., Oturan, N., van Hullebusch, E. D., Guibaud, G., Esposito, G., & Oturan, M. A. (2014) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2014.06.018 · Cited by 105 · cited 1×
“Phenol mineralization was monitored by TOC removal (Mousset et al., 2014), determined on a Shimadzu TOC-VCSH analyzer (Japan) by thermal catalytic oxidation (680°C) (Mousset et al.”
MethodSelf-citationSaien, J., & Shahrezaei, F. (2012) · International Journal of Photoenergy · doi:10.1155/2012/703074 · Cited by 99 · cited 1×
“OH radicals are extremely reactive species that attack most organic molecules with rate constants in the range of 10(8) – 10(10) L mol s towards double carbon bonds, such as aromatic compounds, which constitute the bulk of industrial organic pollutants (Brillas et al., 2009; Castillo-Carvajal et al., 2014; Saien and S…”
BackgroundRodríguez, M. L. (2003) · Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona) · Cited by 97
Electrochemical technologies coupled with biological treatments
Mousset, E., Trellu, C., Olvera‐Vargas, H., Péchaud, Y., Fourcade, F., & Oturan, M. A. (2020) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2020.100668 · Cited by 87 · cited 1×
“Their combination with a biological treatment to remove the biodegradable fraction is particularly encouraged when possible, to decrease the global cost of the treatment (Mousset et al., 2018c; Mousset et al., 2021; Oller et al., 2011; Olvera-Vargas et al., 2016; Rizzo et al., 2020).”
BackgroundSelf-citationBenítez, F. J., Beltran-Heredia, J., Torregrosa, J., & Acero, J. L. (1999) · Journal of Chemical Technology & Biotechnology · doi:10.1002/(sici)1097-4660(199907)74:7<639::aid-jctb92>3.0.co;2-i · Cited by 77 · cited 1×
“Because of the many ways that phenols can be used, they can be found not only in industrial wastewaters but also in soil, groundwater and surface water, following improper waste disposal practices and accidental leakages (Benitez et al., 1999).”
BackgroundMousset, E., Péchaud, Y., Oturan, N., & Oturan, M. A. (2018) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2018.08.055 · Cited by 73 · cited 1×
“For every concentration, the mineralization followed a linear trend because the electro-oxidation reaction of organic compounds at the BDD surface was the rate-limiting step instead of mass transfer limitations (Mousset et al., 2019; Panizza et al., 2001).”
BackgroundSelf-citationFetyan, A., Schneider, J., Schnucklake, M., El‐Nagar, G. A., Banerjee, R., Bevilacqua, N., Zeis, R., & Roth, C. (2018) · ChemElectroChem · doi:10.1002/celc.201801707 · Cited by 65
Photochemical Degradation and Mineralization of Phenol: A Comparative Study
Bali, U., Çokay, E., & Şengül, F. (2003) · Journal of Environmental Science and Health Part A · doi:10.1081/ese-120023373 · Cited by 62 · cited 1×
“UV/H2O2 was the least effective AOP, unable to reach more than 17% of phenol mineralization after 160 min of treatment, a low performance that corroborates former studies (Bali et al., 2003).”
ResultGirish, C. R., & Murty, V. R. (2014) · International Scholarly Research Notices · doi:10.1155/2014/201626 · Cited by 59 · cited 1×
“4 mM (initial TOC: TOC0 = 100 mg-C L), which falls within the common range of phenol concentrations found in various industrial wastewater streams (Girish and Murty, 2014).”
BackgroundBrillas, E. (2017) · Journal of the Mexican Chemical Society · doi:10.29356/jmcs.v58i3.131 · Cited by 57
Mousset, E., Wang, Z., Hammaker, J., & Lefebvre, O. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.11.104 · Cited by 57
Self-citationMousset, E., Pontvianne, S., & Pons, M. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.02.142 · Cited by 55
Self-citationMousset, E., Weiqi, V. H., Kai, B. F. Y., Koh, J. S., Tng, J. W., Wang, Z., & Lefebvre, O. (2017) · Journal of Materials Chemistry A · doi:10.1039/c7ta08182k · Cited by 55
Self-citationDeng, F., Olvera‐Vargas, H., García-Rodríguez, O., Qiu, S., Yang, J., & Lefebvre, O. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.02.186 · Cited by 53 · cited 1×
“Yet, the main advantage of heterogeneous processes would arguably be more in terms of their impact on chemical cost reduction by avoiding the need to adjust the pH to 3 (Deng et al., 2018).”
BackgroundSelf-citationMousset, E., Wang, Z., Olvera‐Vargas, H., & Lefebvre, O. (2018) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2018.08.023 · Cited by 48
Self-citationGirish, C. R., & Murty, V. R. (2015) · Environmental Processes · doi:10.1007/s40710-015-0117-z · Cited by 46
Mousset, E., Quackenbush, L., Schondek, C. N., Gerardin-Vergne, A., Pontvianne, S., Kmiotek, S., & Pons, M. (2020) · Electrochimica Acta · doi:10.1016/j.electacta.2019.135608 · Cited by 42
Self-citationMousset, E., Wang, Z., & Lefebvre, O. (2016) · Water Science & Technology · doi:10.2166/wst.2016.353 · Cited by 38
Self-citationApplication of AOPs in the treatment of OSPAR chemicals and a comparative cost analysis
Huddersman, K. D., Ekpruke, A., & Asuelimen, L. I. (2019) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2018.1537770 · Cited by 17 · cited 1×
“EAOPs offer the benefits to operate with minimal addition of chemicals; yet, there is a lack of systematic studies comparing the costs of various AOPs under the same conditions and for the same application (Huddersman et al., 2019; Miklos et al., 2018).”
Background
Cited by
Saravanan, A., Deivayanai, V. C., Kumar, P. S., Rangasamy, G., Hemavathy, R. V., Harshana, T., Gayathri, N., & Alagumalai, K. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2022.136524 · Cited by 600
ADVANCED OXIDATION PROCESS: A remediation technique for organic and non-biodegradable pollutant
Kumari, P., & Kumar, A. (2023) · Results in Surfaces and Interfaces · doi:10.1016/j.rsurfi.2023.100122 · Cited by 314
Recent advances in electro-Fenton process and its emerging applications
Nidheesh, P. V., Ganiyu, S. O., Martínez-Huitle, C. A., Mousset, E., Olvera-Vargas, H., Trellu, C., Zhou, M., & Oturan, M. A. (2023) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2022.2093074 · Cited by 197
“A recent study highlighted the cost effectiveness (considering operating costs such as sludge management, chemical use and electricity consumption) of EF process compared to ozonation, H2O2 photolysis, Fenton and photo-Fenton at laboratory scale (Mousset et al., 2021).”
BackgroundMethodSelf-citationSatyam, S., & Patra, S. (2025) · Processes · doi:10.3390/pr13040987 · Cited by 170
“TiO is active primarily under UV-A light, which constitutes only a small portion of the solar spectrum, thereby limiting its energy efficiency.”
Microplastic removal and management strategies for wastewater treatment plants
Ahmed, S. F., Islam, N., Tasannum, N., Mehjabin, A., Momtahin, A., Chowdhury, A. A., Almomani, F., & Mofijur, M. (2024) · Chemosphere · doi:10.1016/j.chemosphere.2023.140648 · Cited by 161
Metadata
- Authors
- Mousset, E., Loh, W. H., Lim, W. S., Jarry, L., Wang, Z., & Lefebvre, O.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 200
- Pages
- 117234
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W3161879235
- Cited by
- 192
- References
- 65
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.