Pilot-scale field demonstration of a hybrid nanofiltration and UV-sulfite treatment train for groundwater contaminated by per- and polyfluoroalkyl substances (PFASs)
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Previous laboratory scale studies indicate nanofiltration (NF) and UV-sulfite photochemical treatments as promising technologies for the removal and destruction, respectively, of per- and polyfluoroalkyl substances (PFASs) from contaminated water. This study reports on a field demonstration of a pilot-scale hybrid NF and UV-sulfite treatment train for the remediation of 12 PFASs detected in groundwater impacted by aqueous film-forming foam (AFFF) at a U.S. Department of Defense installation. For most of the detected PFASs, NF rejection was consistently ≥ 95% over a 30-day field trial when operating at 90% total permeate recovery. Rejection of short-chain perfluorosulfonic acids (PFSAs) by NF decreased when recoveries increased from 90 to 97%; tests with a reverse osmosis (RO) membrane showed ≥ 99% rejection of all PFASs regardless of increasing recovery. UV treatment of the NF reject following 90% permeate recovery resulted in variable destruction of individual PFASs, with rates also being dependent on pH and the identity and concentration of UV photosensitizer. Rates of perfluorocarboxylic acid (PFCA) degradation were greater than those measured for PFSAs and perfluoroalkyl acid (PFAA) precursors and were independent of perfluoroalkyl chain length. In contrast, rates of PFSA degradation increased with increasing chain length. Consistent levels of PFAS degradation by UV-sulfite were observed during a 30-day demonstration experiment in NF reject water amended with 10 mM sulfite and adjusted to pH 11.2. Collectively, > 75% of the detected PFAS mass in the NF reject was destroyed after 4 h of UV treatment, increasing to > 90% after 8 h of treatment. An analysis of electrical energy inputs for the hybrid NF/UV-sulfite treatment train showed energy per order magnitude (EE/O) requirements ranging from ≤ 13.1 kWh/m3 for PFCAs and 14.1 kWh/m3 for PFOS to values > 100 kWh/m3 for more recalcitrant short-chain PFSA analogues. The UV reactor and water-cooling system were the major contributors to overall energy requirements and represent the greatest opportunities for improving efficiency of the technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hu, X. C., Andrews, D. Q., Lindstrom, A. B., Bruton, T. A., Schaider, L. A., Grandjean, P., Lohmann, R., Carignan, C. C., Blum, A., Balan, S. A., et al. (2016) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.6b00260 · Cited by 1,333
Self-citationBarzen-Hanson, K. A., Roberts, S. C., Choyke, S., Oetjen, K., McAlees, A., Riddell, N., McCrindle, R., Ferguson, P. L., Higgins, C. P., & Field, J. A. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.6b05843 · Cited by 873
Self-citationCui, J., Gao, P., & Deng, Y. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.9b05565 · Cited by 742
Perfluorinated Surfactants and the Environmental Implications of Their Use in Fire-Fighting Foams
Moody, C. A., & Field, J. A. (2000) · Environmental Science & Technology · doi:10.1021/es991359u · Cited by 707
Nguyen, T. M. H., Bräunig, J., Thompson, K., Thompson, J., Kabiri, S., Navarro, D. A., Kookana, R. S., Grimison, C., Barnes, C. M., Higgins, C. P., et al. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c05705 · Cited by 523
Self-citation
Cited by
Gar Alalm, M., & Boffito, D. C. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.138352 · Cited by 288
Zango, Z. U., Garba, A., Garba, Z. N., Zango, M. U., Usman, F., & Lim, J.-W. (2022) · Sustainability · doi:10.3390/su142416441 · Cited by 105
Ismail, U. M., Elnakar, H., & Khan, M. F. (2023) · Toxics · doi:10.3390/toxics11040335 · Cited by 40
A review of spiral wound membrane modules and processes for groundwater treatment
Tabi, R. N., Boakye, P., Agyemang, F. O., Nxumalo, E. N., & Oduro-Kwarteng, S. (2024) · Frontiers in Membrane Science and Technology · doi:10.3389/frmst.2024.1343651 · Cited by 9
Metadata
- Authors
- Liu, C. J., McKay, G., Jiang, D., Tenorio, R., Cath, J. T., Amador, C., Murray, C. C., Brown, J. B., Wright, H. B., Schaefer, C., Higgins, C. P., Bellona, C., & Strathmann, T. J.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2021-10
- Volume
- 205
- Pages
- 117677
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W3201634941
- Cited by
- 106
- References
- 5
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pilot-scale field demonstration of a hybrid nanofiltration and UV-sulfite treatment train for groundwater contaminated by per- and polyfluoroalkyl substances (PFASs). https://app.cochat.ai/papers/10.1016/j.watres.2021.117677
- The paper
- Liu, C. J., McKay, G., Jiang, D., Tenorio, R., Cath, J. T., Amador, C., Murray, C. C., Brown, J. B., Wright, H. B., Schaefer, C., Higgins, C. P., Bellona, C., & Strathmann, T. J. (2021). Pilot-scale field demonstration of a hybrid nanofiltration and UV-sulfite treatment train for groundwater contaminated by per- and polyfluoroalkyl substances (PFASs). Water Research. https://doi.org/10.1016/j.watres.2021.117677
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.