Cited by 4Thermoregulation and physiological responsesThermal Regulation in MedicineInfrared Thermography in Medicine

Detection and management of hypothermia at a large outdoor endurance event in the United Kingdom

Bhangu, Aneel, Parmar, Rinesh·2010·Wilderness & Environmental Medicine

Abstract

OBJECTIVE: Optimum detection of hypothermia in athletes during outdoor exposure events remains controversial. The aims of this study were firstly to assess whether temperature readings affected competitor discharge from the treatment station and secondly to assess agreement between oral and tympanic thermometer measurements. METHODS: All competitors treated for symptomatic hypothermia at an outdoor endurance event in the United Kingdom during January 2009 were included. Temperature readings were taken using oral (Digitemp digital oral thermometer) and tympanic (Braun Thermoscan IRT 4520 ExacTemp) thermometers, with a temperature <35 degrees C classifying hypothermia. RESULTS: From 4700 competitors, 64 (1.4%) were treated for symptomatic hypothermia. Of these, 92% were male, the mean age was 26 years, and the mean treatment time was 25 minutes. There was no severe/life-threatening hypothermia, and no competitors required transport to a hospital for hypothermia. At discharge, 19% of competitors were still classed as hypothermic in the oral group and 28% in the tympanic group, despite competitors only being discharged when no longer symptomatic. Oral readings at discharge were significantly lower than tympanic readings (33.8 degrees C [95% CI, 33.2 degrees C to 34.5 degrees C] vs 35.0 degrees C [95% CI, 34.6 degrees C to 35.3 degrees C], respectively, P = .003). CONCLUSIONS: The use of thermometers had a limited role in discharging competitors at this event, who were apparently safely discharged when no longer symptomatic. Treating clinicians and the thermometers did not always agree on whether a patient was hypothermic or not. Oral and tympanic thermometers had poor agreement. Routine thermometer readings at future events may be unnecessary, although screening competitors of concern will remain useful.

Integrity signals

Registry

Crossref · 10.1016/j.wem.2009.12.003

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Bhangu, A., & Parmar, R.
Affiliations
  • St John Ambulance, West Midlands, Birmingham, United Kingdom
  • University of Birmingham (GB)
Venue
Wilderness & Environmental Medicine
Published
2010-06
Volume
21
Issue
2
Pages
141-145
ISSN
  • 1080-6032 (ISSN-L)
  • 1545-1534
OpenAlex
W1999960500
Cited by
4
References
10
Citations by year
2021: 1 · 2020: 2 · 2019: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • Wilderness and Environmental Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
Keywords
hypothermia, athletes, oral temperature, tympanic temperature, hypothermia management, cold exposure
MeSH terms
Adult, Cold Temperature, Female, United Kingdom, Humans, Hypothermia, Male, Sports, Thermometers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review