CoChat

Application of human stem cell-derived cardiomyocytes in safety pharmacology requires caution beyond hERG

Open access
Jonsson, Malin K.B., Vos, Marc A., Mirams, Gary R., Duker, Göran, Sartipy, Peter, de Boer, Teun P., van Veen, Toon A.B. · 2012 · Journal of Molecular and Cellular Cardiology
Cited by 137

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Human embryonic stem cell-derived cardiomyocytes (hESC-CM) have been proposed as a new model for safety pharmacology. So far, a thorough description of their basic electrophysiology and extensive testing, and mechanistic explanations, of their overall pro-arrhythmic ability is lacking. Under standardized conditions, we have evaluated the sensitivity of hESC-CM to proarrhythmic provocations by blockade of hERG and other channels. Using voltage patch clamp, some ion current densities (pA/pF) in hESC-CM were comparable to adult CM: I(Kr) (-12.5 ± 6.9), I(Ks) (0.65 ± 0.12), I(Na,peak) (-72 ± 21), I(Na,late) (-1.10 ± 0.36), and I(Ca,L) (-4.3 ± 0.6). I(f) density was larger (-10 ± 1.1) and I(K1) not existent or very small (-2.67 ± 0.3). The low I(K1) density was corroborated by low KCNJ2 mRNA levels. Effects of pro-arrhythmic compounds on action potential (AP) parameters and provocation of early afterdepolarizations (EADs) revealed that Chromanol293B (100 μmol/l) and Bay K8644 (1 μmol/l) both significantly prolonged APD(90). ATX-II (<1 μmol/l ) and BaCl(2) (10 μmol/l ) had no effect on APD. The only compound that triggered EADs was hERG blocker Cisapride. Computer simulations and AP clamp showed that the immature AP of hESC-CM prevents proper functioning of I(Na)-channels, and result in lower peak/maximal currents of several other channels, compared to the adult situation. Lack of functional I(K1) channels and shifted I(Na) channel activation cause a rather immature electrophysiological phenotype in hESC-CM, and thereby limits the potential of this model to respond accurately to pro-arrhythmic triggers other than hERG block. Maturation of the electrical phenotype is a prerequiste for future implementation of the model in arrhythmogenic safety testing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.yjmcc.2012.02.002

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 137

Metadata

Authors
Jonsson, M. K. B., Vos, M. A., Mirams, G. R., Duker, G., Sartipy, P., de Boer, T. P., & van Veen, T. A. B.
Venue
Journal of Molecular and Cellular Cardiology
Publisher
Elsevier BV
Published
2012-05
Volume
52
Issue
5
Pages
998-1008
ISSN
0022-2828 (ISSN-L)
OpenAlex
W2013430991
Cited by
137
References
5
FWCI
12.28
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of human stem cell-derived cardiomyocytes in safety pharmacology requires caution beyond hERG. https://app.cochat.ai/papers/10.1016/j.yjmcc.2012.02.002
The paper
Jonsson, M. K. B., Vos, M. A., Mirams, G. R., Duker, G., Sartipy, P., de Boer, T. P., & van Veen, T. A. B. (2012). Application of human stem cell-derived cardiomyocytes in safety pharmacology requires caution beyond hERG. Journal of Molecular and Cellular Cardiology. https://doi.org/10.1016/j.yjmcc.2012.02.002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.