A negative selection methodology using a microfluidic platform for the isolation and enumeration of circulating tumor cells
Open accessThe DOI matches its Crossref record.
Abstract
Circulating tumor cells (CTCs) exist in the peripheral blood stream of metastatic cancer patients at rates of approximately 1 CTC per billion background cells. In order to capture and analyze this rare cell population, various techniques exist that range from antibody-based surface marker positive selection to methods that use physical properties of CTCs to negatively exclude background cells from a CTC population. However, methods to capture cells for functional downstream analyses are limited due to inaccessibility of the captured sample or labeling techniques that may be prohibitive to cell function. Here, we present a negative selection method that leverages a microfluidic cell concentrator (MCC) to allow collection and analysis of this rare cell population without needing cell adhesion or other labeling techniques to keep the cells within the chamber. Because the MCC is designed to allow collection and analysis of non-adherent cell populations, multiple staining steps can be applied in parallel to a given CTC population without losing any of the population. The ability of the MCC for patient sample processing of CTCs for enumeration was demonstrated with five patient samples, revealing an average of 0.31 CTCs per mL. The technique was compared to a previously published method – the ELISPOT – that showed similar CTC levels among the five patient samples tested. Because the MCC method does not use positive selection, the method can be applied across a variety of tumor types with no changes to the process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood-Based Analyses of Cancer: Circulating Tumor Cells and Circulating Tumor DNA
Haber, D. A., & Velculescu, V. E. (2014) · Cancer Discovery · doi:10.1158/2159-8290.cd-13-1014 · Cited by 694
Circulating tumor cell technologies
Ferreira, M. M., Ramani, V. C., & Jeffrey, S. S. (2016) · Molecular Oncology · doi:10.1016/j.molonc.2016.01.007 · Cited by 511
Kelley, S. O., Mirkin, C. A., Walt, D. R., Ismagilov, R. F., Toner, M., & Sargent, E. H. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.261 · Cited by 398
Ignatiadis, M., Lee, M., & Jeffrey, S. S. (2015) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-14-1190 · Cited by 355
Recent advances in microfluidic methods in cancer liquid biopsy
Iliescu, F. S., Poenar, D. P., Yu, F., Ni, M., Chan, K. H., Cima, I., Taylor, H. K., Cima, I., & Iliescu, C. (2019) · Biomicrofluidics · doi:10.1063/1.5087690 · Cited by 51
Micro/nanofluidic technologies for efficient isolation and detection of circulating tumor cells
Yue, W.-Q., Tan, Z., Li, X.-P., Liu, F.-F., & Wang, C. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.009 · Cited by 34
An integrated microfluidic platform for negative selection and enrichment of cancer cells 6
Luo, W.-Y., Tsai, S.-C., Hsieh, K., & Lee, G.-B. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/8/084007 · Cited by 18
Metadata
- Authors
- Casavant, B. P., Mosher, R., Warrick, J. W., Maccoux, L. J., Berry, S. M. F., Becker, J. T., Chen, V., Lang, J. M., McNeel, D. G., & Beebe, D. J.
- Venue
- Methods
- Publisher
- Elsevier BV
- Published
- 2013-12
- Volume
- 64
- Issue
- 2
- Pages
- 137-143
- ISSN
- 1046-2023 (ISSN-L)
- OpenAlex
- W2030883654
- Cited by
- 51
- References
- 0
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.