Cited by 167Structural Health Monitoring TechniquesMasonry and Concrete Structural AnalysisInfrastructure Maintenance and Monitoring

Temperature effects on static and dynamic behavior of Consoli Palace in Gubbio, Italy

Kita, Alban, Cavalagli, Nicola, Ubertini, Filippo·2019·Mechanical Systems and Signal Processing

Integrity signals

Registry

Crossref · 10.1016/j.ymssp.2018.10.021

Cites

70 of 70 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

2 of the 72 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Kita, A., Cavalagli, N., & Ubertini, F.
Affiliations
University of Perugia (IT)
Corresponding author
Ubertini, Filippo
Venue
Mechanical Systems and Signal Processing
Publisher
Elsevier BV
Published
2019-04
Volume
120
Pages
180-202
ISSN
0888-3270 (ISSN-L)
OpenAlex
W2898347655
Cited by
167
References
72
Citations by year
2026: 18 · 2025: 20 · 2024: 24 · 2023: 30 · 2022: 16 · 2021: 25 · 2020: 23 · 2019: 11
FWCI
13.27
Type
journal article
Language
en
Open access
closed
Locations
Mechanical Systems and Signal Processing (publishedVersion)
Funders
HORIZON (700395)
Topics
  • Physical Sciences › Engineering › Civil and Structural Engineering › Structural Health Monitoring Techniques
  • Physical Sciences › Engineering › Civil and Structural Engineering › Masonry and Concrete Structural Analysis
  • Physical Sciences › Engineering › Civil and Structural Engineering › Infrastructure Maintenance and Monitoring
Keywords
Gubbio, historic masonry buildings, ambient temperature effects, structural health monitoring, damage detection, natural frequencies, ambient vibration testing, dynamic regression, earthquake damage, material degradation, static and dynamic response, long-term monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review