Fetal echocardiography
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
“With the sample cursor placed through the more trabeculated right atrium and either ventricle, the relationship between atrial and ventricular contractions can be demonstrated, and heart rate can be measured.(60,61) Pulsed Doppler recordings of simultaneous left ventricular inflow and outflow,(251) superior vena cava…”
BackgroundCheitlin, M. D., Alpert, J. S., Armstrong, W. F., Aurigemma, G. P., Beller, G. A., Bierman, F. Z., Davidson, T. W., Davis, J. L., Douglas, P. S., Gillam, L. D., et al. (1997) · Circulation · doi:10.1161/01.cir.95.6.1686 · Cited by 831
Rychik, J., Ayres, N., Cuneo, B., Gotteiner, N., Hornberger, L., Spevak, P. J., & Van Der Veld, M. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.04.011 · Cited by 458
Perinatal outcome of fetal complete atrioventricular block: A multicenter experience
Schmidt, K. G., Ulmer, H. E., Silverman, N. H., Kleinman, C. S., & Copel, J. A. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80148-2 · Cited by 344
Self-citationThe clinical spectrum of autoimmune congenital heart block
Brito-Zerón, P., Izmirly, P. M., Ramos-Casals, M., Buyon, J. P., & Khamashta, M. A. (2015) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2015.29 · Cited by 305
Fetal tachycardias: management and outcome of 127 consecutive cases
Simpson, J. M., & Sharland, G. K. (1998) · Heart · doi:10.1136/hrt.79.6.576 · Cited by 303
Hydrops revisited: Literature review of 1, 414 cases published in the 1980s
Machin, G. A. (1989) · American Journal of Medical Genetics · doi:10.1002/ajmg.1320340313 · Cited by 259
Tricuspid valve disease with significant tricuspid insufficiency in the fetus: Diagnosis and outcome
Hornberger, L. K., Sahn, D. J., Kleinman, C. S., Copel, J. A., & Reed, K. L. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90722-l · Cited by 234
Self-citationCardiac Doppler flow velocities in human fetuses.
Reed, K. L., Meijboom, E. J., Sahn, D. J., Scagnelli, S. A., Valdes-Cruz, L. M., & Shenker, L. (1986) · Circulation · doi:10.1161/01.cir.73.1.41 · Cited by 231
Fetal ventricular pacing for hydrops secondary to complete atrioventricular block
Carpenter, R. J., Strasburger, J. F., Garson, A., Smith, R. T., Deter, R. L., & Tristan Engelhardt, H. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80319-9 · Cited by 185
Independent component analysis: fetal signal reconstruction from magnetocardiographic recordings
Comani, S., Mantini, D., Pennesi, P., Lagatta, A., & Cancellieri, G. (2004) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2003.12.005 · Cited by 46
COMANI, S., LIBERATI, M., MANTINI, D., GABRIELE, E., BRISINDA, D., DI LUZIO, S., FENICI, R., & LUCA ROMANI, G. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00699.x · Cited by 38
Metadata
- Authors
- Kleinman, C. S., Donnerstein, R. L., Jaffe, C. C., DeVore, G. R., Weinstein, E. M., Lynch, D. C., Talner, N. S., Berkowitz, R. L., & Hobbins, J. C.
- Venue
- The American Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 1983-01
- Volume
- 51
- Issue
- 2
- Pages
- 237-243
- ISSN
- 0002-9149 (ISSN-L)
- OpenAlex
- W1917269741
- Cited by
- 200
- References
- 0
- FWCI
- 18.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.