CoChat

Characterization of autonomic dysfunction in patients with irritable bowel syndrome by means of heart rate variability studies

Adeyemi, E · 1999 · The American Journal of Gastroenterology
Cited by 101

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Our aim was to characterize autonomic dysfunction in patients with irritable bowel syndrome (IBS) using heart rate variability (HRV) studies. METHODS: EKG signals were obtained from 35 patients (mean age, 39.1 +/- 9.5 yr, M:F ratio = 2.9:1) and 18 healthy controls (mean age, 38.2 +/- 6.5 yr, M:F ratio = 2:1) in supine, standing, and deep-breathing modes. Fast Fourier transformation and autoregressive techniques were used to analyze the HRV power spectra in very low (VLF, 0.0078-0.04 Hz), low (LF, 0.04-0.14 Hz), and high (HF, 0.14-0.4 Hz) frequency bands. RESULTS: In the supine position, the VLF power spectral density (PSD) in IBS was significantly higher than normal (3 vs 1.3 beats per minute [bpm]2/Hz, p < 0.01). On changing from the supine to standing position, the normals (NC) had raised median PSDs in the VLF (1.3 vs 12.8 bpm2/Hz, p < 0.01) and LF (1.6 vs 6.1 bpm2/Hz, p < 0.01) bands, as a sign of increased sympathetic tone, whereas the median HF PSDs (parasympathetic tone) remained unchanged (1.8 bpm2/Hz each, p = 0.8). Similarly, the IBS patients had increased VLF (3.04 vs 14.93 bpm2/Hz, p < 0.01) and LF (2.8 vs 8.7 bpm2/Hz, p < 0.01) PSDs on standing up, but the HF PSD was also raised (from 2.4 to 5.7 bpm2/Hz, p = 0.04). On changing from standing to the deep-breathing mode, the normals had a significant increase in the HF (from 1.8 to 10.3 bpm2/Hz, p < 0.001) and a significant reduction of the VLF (from 12.8 to 2.2 bpm2/Hz, p < 0.01) PSDs. The reduction of the LF PSD was not significant (from 6.1 to 5.6 bpm2/Hz, p = 0.6). In IBS, HF PSD remained constant (5.7 bpm2/Hz each, p = 0.6), whereas the LF PSD increased from 8.7 to 24.2 bpm2/Hz (p < 0.0001). The VLF PSD was reduced (from 14.9 to 4.1 bpm2/Hz, p < 0.0001). In IBS, the median sympathovagal outflow ratio was significantly lower in the standing position (1.4 vs 2.8, p < 0.02) and higher in the deep-breathing mode (7.33 vs 0.42, p < 0.0001) than normal. CONCLUSIONS: IBS patients have reduced sympathetic influence on the heart period in response to orthostatic stress and diminished parasympathetic modulation during deep breathing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0002-9270(98)00742-4

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 101

Metadata

Authors
Adeyemi, E.
Venue
The American Journal of Gastroenterology
Published
1999-03
Volume
94
Issue
3
Pages
816-823
ISSN
0002-9270 (ISSN-L)
OpenAlex
W2064432531
Cited by
101
References
7
FWCI
3.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization of autonomic dysfunction in patients with irritable bowel syndrome by means of heart rate variability studies. https://app.cochat.ai/papers/10.1016/s0002-9270(98)00742-4
The paper
Adeyemi, E. (1999). Characterization of autonomic dysfunction in patients with irritable bowel syndrome by means of heart rate variability studies. The American Journal of Gastroenterology. https://doi.org/10.1016/s0002-9270(98)00742-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.