Coenzyme Q10: The Prophylactic Effect on Low Cardiac Output Following Cardiac Valve Replacement
Open accessThe DOI matches its Crossref record.
Abstract
A randomized, prospective study of the effectiveness of preoperative administration of coenzyme Q10 on the prophylaxis of postoperative low cardiac output state was performed in 50 patients with acquired valvular diseases necessitating valve replacement. There were 25 patients in the treatment group and 25 in the control group. Patients in the treatment group received 30 to 60 mg of coenzyme Q10 orally for six days before operation. Preoperative clinical variables, operative procedures, total cardiopulmonary bypass time, and aortic cross-clamping time were similar for the two groups. Postoperatively, mild to severe low cardiac output state developed in 28 of 50 patients (56%) and necessitated the administration of considerable amounts of inotropic agent. The treatment group showed a significantly lower incidence of low cardiac output state during the recovery period than the control group (p less than 0.05). These results suggest that preoperative administration of coenzyme Q10 will increase the tolerance of human hearts to ischemia during aortic cross-clamping.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ubiquinol-10 is an effective lipid-soluble antioxidant at physiological concentrations.
Frei, B., Kim, M. C., & Ames, B. N. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.12.4879 · Cited by 620
Reperfusion injury: a review of the pathophysiology, clinical manifestations and therapeutic options
Maxwell, S. R. J., & Lip, G. Y. H. (1997) · International Journal of Cardiology · doi:10.1016/s0167-5273(96)02854-9 · Cited by 405
Co‐Enzyme Q10: A New Drug for Cardiovascular Disease
Greenberg, S., & Frishman, W. H. (1990) · The Journal of Clinical Pharmacology · doi:10.1002/j.1552-4604.1990.tb01862.x · Cited by 207
Mechanick, J. I., Brett, E. M., Chausmer, A. B., Dickey, R. A., Wallach, S., Bergman, D. A., Garber, J. R., Hamilton, C. R., Handelsman, Y., Holdy, K. E., et al. (2003) · Endocrine Practice · doi:10.4158/ep.9.5.417 · Cited by 73
Carrasco, J., Anglada, F. J., Campos, J. P., Muntané, J., Requena, M. J., & Padillo, J. (2014) · BJU International · doi:10.1111/bju.12485 · Cited by 26
Metadata
- Authors
- Tanaka, J., Tominaga, R., Yoshitoshi, M., Matsui, K., Komori, M., Sese, A., Yasui, H., & Tokunaga, K.
- Venue
- The Annals of Thoracic Surgery
- Publisher
- Elsevier BV
- Published
- 1982-02
- Volume
- 33
- Issue
- 2
- Pages
- 145-151
- ISSN
- 0003-4975 (ISSN-L)
- OpenAlex
- W1965083163
- Cited by
- 54
- References
- 0
- FWCI
- 0.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coenzyme Q10: The Prophylactic Effect on Low Cardiac Output Following Cardiac Valve Replacement. https://app.cochat.ai/papers/10.1016/s0003-4975(10)61900-5
- The paper
- Tanaka, J., Tominaga, R., Yoshitoshi, M., Matsui, K., Komori, M., Sese, A., Yasui, H., & Tokunaga, K. (1982). Coenzyme Q10: The Prophylactic Effect on Low Cardiac Output Following Cardiac Valve Replacement. The Annals of Thoracic Surgery. https://doi.org/10.1016/s0003-4975(10)61900-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.