Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Randomized, Double-Blind Trial of Inhaled Nitric Oxide in LVAD Recipients With Pulmonary Hypertension

Open access
Argenziano, Michael, Choudhri, Asim F, Moazami, Nader, Rose, Eric A, Smith, Craig R, Levin, Howard R, Smerling, Arthur J, Oz, Mehmet C · 1998 · The Annals of Thoracic Surgery

Abstract

BACKGROUND: Pulmonary vascular resistance is often elevated in patients with congestive heart failure, and in those undergoing left ventricular assist device (LVAD) insertion, it may precipitate right ventricular failure and hemodynamic collapse. Because the effectiveness of inotropic and vasodilatory agents is limited by systemic effects, right ventricular assist devices are often required. Inhaled nitric oxide (NO) is an effective, specific pulmonary vasodilator that has been used successfully in the management of pulmonary hypertension. METHODS: Eleven of 23 patients undergoing LVAD insertion met criteria for elevated pulmonary vascular resistance on weaning from cardiopulmonary bypass (mean pulmonary artery pressure > 25 mm Hg and LVAD flow rate < 2.5 L x min[-1] x m[-2]) and were randomized to receive either inhaled NO at 20 ppm (n = 6) or nitrogen (n = 5). Patients not manifesting a clinical response after 15 minutes were given the alternative agent. RESULTS: Hemodynamics for the group at randomization were as follows: mean arterial pressure, 72 +/- 6 mm Hg; mean pulmonary artery pressure, 32 +/- 4 mm Hg; and LVAD flow, 2.0 +/- 0.3 L x min(-1) x m(-2). Patients receiving inhaled NO exhibited significant reductions in mean pulmonary artery pressure and increases in LVAD flow, whereas none of the patients receiving nitrogen showed hemodynamic improvement. Further, when the nitrogen group was subsequently given inhaled NO, significant hemodynamic improvements ensued. There were no significant changes in mean arterial pressure in either group. CONCLUSIONS: Inhaled NO induces significant reductions in mean pulmonary artery pressure and increases in LVAD flow in LVAD recipients with elevated pulmonary vascular resistance. We conclude that inhaled NO is a useful intraoperative adjunct in patients undergoing LVAD insertion in whom pulmonary hypertension limits device filling and output.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0003-4975(97)01307-6

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 238

Metadata

Authors
Argenziano, M., Choudhri, A. F., Moazami, N., Rose, E. A., Smith, C. R., Levin, H. R., Smerling, A. J., & Oz, M. C.
Venue
The Annals of Thoracic Surgery
Publisher
Elsevier BV
Published
1998-02
Volume
65
Issue
2
Pages
340-345
ISSN
0003-4975 (ISSN-L)
OpenAlex
W2009010790
Cited by
238
References
2
FWCI
15.20
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomized, Double-Blind Trial of Inhaled Nitric Oxide in LVAD Recipients With Pulmonary Hypertension. https://app.cochat.ai/papers/10.1016/s0003-4975(97)01307-6
The paper
Argenziano, M., Choudhri, A. F., Moazami, N., Rose, E. A., Smith, C. R., Levin, H. R., Smerling, A. J., & Oz, M. C. (1998). Randomized, Double-Blind Trial of Inhaled Nitric Oxide in LVAD Recipients With Pulmonary Hypertension. The Annals of Thoracic Surgery. https://doi.org/10.1016/s0003-4975(97)01307-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.