Role of pulse shape in cell membrane electropermeabilization
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theory of electroporation: A review
Weaver, J. C., & Chizmadzhev, Y. A. (1996) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(96)05062-3 · Cited by 1,599 · cited 1×
“The importance of the duration of above-critical VDR is also compatible with the theory of electroporation, which attributes the increase of plasma membrane permeability to the formation of hydrophilic structures (‘‘aqueous pores’’) traversing the lipid bilayer and lined with the lipid headgroups [9].”
BackgroundElectroporation of cell membranes
Tsong, T. Y. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82054-9 · Cited by 1,094 · cited 1×
“In parallel with the practical use of the method continues the quest for understanding the underlying mechanisms of the phenomenon [3,7–12].”
MethodHigh-efficiency gene transfer into skeletal muscle mediated by electric pulses
Mir, L. M., Bureau, M. F., Gehl, J., Rangara, R., Rouy, D., Caillaud, J.-M., Delaere, P., Branellec, D., Schwartz, B., & Scherman, D. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.8.4262 · Cited by 914 · cited 1×
“Because electropermeabilization is usually not performed with continuous waves, but with sequences (trains) of separate pulses [18,22–25], our group compared the efficiency of unipolar and symmetrical bipolar rectangular pulses, in both cases delivering eight 1-ms pulses at 1-s intervals [26].”
MethodSelf-citationBiedler, J. L., & Riehm, H. (1970) · PubMed · Cited by 747
Effective treatment of cutaneous and subcutaneous malignant tumours by electrochemotherapy
Mir, L., Glass, L., Serša, G., Teissié, J., Domenge, C., Miklavčič, D., Jaroszeski, M., Orlowski, S., Reintgen, D., Rudolf, Z., et al. (1998) · British Journal of Cancer · doi:10.1038/bjc.1998.388 · Cited by 444
Self-citationFundamentals of electroporative delivery of drugs and genes
Neumann, E., Kakorin, S., & Tœnsing, K. (1999) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(99)00008-2 · Cited by 402 · cited 1×
“Electropermeabilization (also termed electroporation) is an effective method of internalization of various molecules into biological cells, with an increasing number of applications in oncology [1,2], genetics [3], immunology [4], and cell biology [5,6].”
MethodElectropermeabilization of mammalian cells. Quantitative analysis of the phenomenon
Rols, M. P., & Teissié, J. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82451-6 · Cited by 394
Bobinnec, Y., Khodjakov, A., Mir, L. M., Rieder, C. L., Eddé, B., & Bornens, M. (1998) · The Journal of Cell Biology · doi:10.1083/jcb.143.6.1575 · Cited by 377
Self-citationElectropermeabilization of skeletal muscle enhances gene transfer in vivo
Mathiesen, I. (1999) · Gene Therapy · doi:10.1038/sj.gt.3300847 · Cited by 372 · cited 1×
“Even before these studies were published, bipolar pulses were applied successfully in electrochemotherapy [28], as well as for DNA transfection in vivo in mice [29,30].”
BackgroundElectropermeabilization of Mammalian Cells to Macromolecules: Control by Pulse Duration
Rols, M.-P., & Teissié, J. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)74060-3 · Cited by 347 · cited 2×
“Investigations of the role of the amplitude, number, and duration of unipolar rectangular pulses have been the subject of several comprehensive studies [16–20].”
BackgroundMethodSukharev, S. I., Klenchin, V. A., Serov, S. M., Chernomordik, L. V., & YuA, C. (1992) · Biophysical Journal · doi:10.1016/s0006-3495(92)81709-5 · Cited by 326
Efficient and regulated erythropoietin production by naked DNA injection and muscle electroporation
Rizzuto, G., Cappelletti, M., Maione, D., Savino, R., Lazzaro, D., Costa, P., Mathiesen, I., Cortese, R., Ciliberto, G., Laufer, R., et al. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.11.6417 · Cited by 325 · cited 1×
“Even before these studies were published, bipolar pulses were applied successfully in electrochemotherapy [28], as well as for DNA transfection in vivo in mice [29,30].”
BackgroundHibino, M., Itoh, H., & Kinosita, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81550-9 · Cited by 306
Satkauskas, S., Bureau, M. F., Puc, M., Mahfoudi, A., Scherman, D., Miklavcic, D., & Mir, L. M. (2002) · Molecular Therapy · doi:10.1006/mthe.2002.0526 · Cited by 306 · cited 1×
“Keywords: Electropermeabilization; Electroporation; Pulse shape; Cell survival; Cell membrane permeability; Molecular uptake”
BackgroundSelf-citationVoltage-induced conductance in human erythrocyte membranes
Kinosita, K., & Tsong, T. Y. (1979) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(79)90386-9 · Cited by 249 · cited 5×
“Kinosita and Tsong [31] used linearly increasing electric fields with rates of increase from 12.5 V/ cm per microsecond up to 50 V/cm per microsecond for permeabilization of erythrocytes, and concluded that field intensity at which permeabilization occurs is not affected by this rate of increase.”
BackgroundResultInfluentialSensitivity of transmembrane voltage induced by applied electric fields—A theoretical analysis
Kotnik, T., Bobanović, F., & Miklavcˇicˇ, D. (1997) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(97)00023-8 · Cited by 247 · cited 1×
“Since the induced transmembrane voltage is proportional to the electric field [10], and thus practically proportional to the VDR (see Materials and methods section, Exposure to electric pulses subsection), this explains”
BackgroundSelf-citationControl of Lipid Membrane Stability by Cholesterol Content
Raffy, S., & Teissié, J. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77363-7 · Cited by 245 · cited 1×
“The efficiency of electropermeabilization in vitro depends on various physical and chemical parameters, such as the molecular composition of the membrane [13,14] and osmotic pressure [15], but above all, on the parameters of electric pulses.”
BackgroundControl by pulse parameters of electric field-mediated gene transfer in mammalian cells
Wolf, H., Rols, M. P., Boldt, E., Neumann, E., & Teissié, J. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80805-7 · Cited by 230
Cell poration and cell fusion using an oscillating electric field
Chang, D. C. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82711-0 · Cited by 214 · cited 1×
“reported an improved efficiency of cell permeabilization and fusion [32], as well as gene transfection [33] when a sine wave (40 kHz–1 MHz) was superimposed to a rectangular pulse.”
BackgroundTekle, E., Astumian, R. D., & Chock, P. B. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.10.4230 · Cited by 192 · cited 1×
“[21] compared continuous unipolar and bipolar 60-kHz rectangular waves of 400 As total duration, and obtained a significantly better DNA”
BackgroundGabriel, B., & Teissié, J. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77370-4 · Cited by 181 · cited 1×
“In parallel with the practical use of the method continues the quest for understanding the underlying mechanisms of the phenomenon [3,7–12].”
MethodCell membrane electropermeabilization by symmetrical bipolar rectangular pulses
Kotnik, T., Mir, L. M., Flisar, K., Puc, M., & Miklavčič, D. (2001) · Bioelectrochemistry · doi:10.1016/s1567-5394(01)00114-1 · Cited by 159 · cited 1×
“Keywords: Electropermeabilization; Electroporation; Pulse shape; Cell survival; Cell membrane permeability; Molecular uptake”
BackgroundSelf-citationControl by Osmotic Pressure of Voltage-Induced Permeabilization and Gene Transfer in Mammalian Cells
Golzio, M., Mora, M.-P., Raynaud, C., Delteil, C., Teissié, J., & Rols, M. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)78009-9 · Cited by 156 · cited 1×
“The efficiency of electropermeabilization in vitro depends on various physical and chemical parameters, such as the molecular composition of the membrane [13,14] and osmotic pressure [15], but above all, on the parameters of electric pulses.”
BackgroundCell membrane electropermeabilization by symmetrical bipolar rectangular pulses
Kotnik, T., Miklavčič, D., & Mir, L. M. (2001) · Bioelectrochemistry · doi:10.1016/s1567-5394(01)00115-3 · Cited by 149
Self-citationQuantitative model of small molecules uptake after in vitro cell electropermeabilization
Puc, M., Kotnik, T., Mir, L. M., & Miklavčič, D. (2003) · Bioelectrochemistry · doi:10.1016/s1567-5394(03)00021-5 · Cited by 141 · cited 1×
“However, in a recent theoretical paper [41], we showed that the two-parameter sigmoidal curves as given above are also in good agreement with the permeabilization and survival curves that would correspond to a Gaussian distribution of cell radii.”
BackgroundSelf-citationRols, M., & Teissié, J. (1989) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1989.tb14527.x · Cited by 133 · cited 1×
“[39]) with electrical conductivity of 0.”
High efficiency gene transfection by electroporation using a radio-frequency electric field
Chang, D. C., Gao, P.-Q., & Maxwell, B. L. (1991) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/0167-4889(91)90149-r · Cited by 100 · cited 1×
“reported an improved efficiency of cell permeabilization and fusion [32], as well as gene transfection [33] when a sine wave (40 kHz–1 MHz) was superimposed to a rectangular pulse.”
BackgroundElectrochemotherapy: An emerging drug delivery method for the treatment of cancer
Jaroszeski, M. J., Gilbert, R., & Heller, R. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00034-3 · Cited by 98 · cited 1×
“Because electropermeabilization is usually not performed with continuous waves, but with sequences (trains) of separate pulses [18,22–25], our group compared the efficiency of unipolar and symmetrical bipolar rectangular pulses, in both cases delivering eight 1-ms pulses at 1-s intervals [26].”
MethodEvaluation of Cell Membrane Electropermeabilization by Means of a Nonpermeant Cytotoxic Agent
Kotnik, T., Maček-Lebar, A., Miklavčič, D., & Mir, L. M. (2000) · BioTechniques · doi:10.2144/00285st05 · Cited by 68 · cited 1×
“An intact membrane is impermeable to bleomycin, and while at 5 nM external concentration bleomycin has no effect on nonpermeabilized cells, it causes the death of electropermeabilized cells [40].”
BackgroundSelf-citationSerša, G., Kranjc, S., & Čemažar, M. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00464-2 · Cited by 61 · cited 1×
“Electropermeabilization (also termed electroporation) is an effective method of internalization of various molecules into biological cells, with an increasing number of applications in oncology [1,2], genetics [3], immunology [4], and cell biology [5,6].”
MethodXie, T. D., & Tsong, T. Y. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82434-6 · Cited by 53 · cited 1×
“Xie and Tsong [ 34 ] compared rectangular, sine, and triangular waves with extremely long durations (1‐100 s) and relatively low amplitudes (voltage-to-distance ratio 50‐200 V/cm), obtaining the most efficient transfection for rectangular, less for sine, and the least for triangular waves.”
BackgroundCell electropermeabilization to small molecules in vitro: control by pulse parameters
Maček-Lebar, A., & Miklavčič, D. (2001) · Radiology and Oncology · Cited by 46
Self-citationEfficient transfer of antibodies into mammalian cells by electroporation
Lukas, J., Bártek, J., & Strauss, M. (1994) · Journal of Immunological Methods · doi:10.1016/0022-1759(94)90400-6 · Cited by 45 · cited 1×
“Electropermeabilization (also termed electroporation) is an effective method of internalization of various molecules into biological cells, with an increasing number of applications in oncology [1,2], genetics [3], immunology [4], and cell biology [5,6].”
MethodElectrooptics of membrane electroporation and vesicle shape deformation
Neumann, E., & Kakorin, S. (1996) · Current Opinion in Colloid & Interface Science · doi:10.1016/s1359-0294(96)80083-5 · Cited by 41 · cited 1×
“In parallel with the practical use of the method continues the quest for understanding the underlying mechanisms of the phenomenon [3,7–12].”
MethodChanges in Electroporation Thresholds of Lipid Membranes by Surfactants and Peptides
Tung, L., Troiano, G. C., Sharma, V., Raphael, R. M., & Stebe, K. J. (1999) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1999.tb07960.x · Cited by 36 · cited 1×
“The efficiency of electropermeabilization in vitro depends on various physical and chemical parameters, such as the molecular composition of the membrane [13,14] and osmotic pressure [15], but above all, on the parameters of electric pulses.”
BackgroundCell membrane electropermeabilization with arbitrary pulse waveforms
Flisar, K., Puc, M., Kotnik, T., & Miklavčič, D. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1191453 · Cited by 24
Self-citationDirect monitoring of the field strength during electropulsation
Loste, F., Eynard, N., & Teissié, J. (1998) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(98)00183-4 · Cited by 24 · cited 1×
“Since for stainless steel electrodes, the voltage drop at the electrode–electrolyte interface is very small [37], and the dimensions of the droplet in the plane parallel to the electrode plates were several times larger than the distance between the electrodes, the VDR is also a good estimate of the electric field wit…”
BackgroundSignificance of Treatment Energy in Cell Electropermeabilization
Lebar, A. M., Kopitar, A. N., Ihan, A., Serša, G., & Damijan Miklavčič, A. (1998) · Electro- and Magnetobiology · doi:10.3109/15368379809022570 · Cited by 13 · cited 1×
“Investigations of the role of the amplitude, number, and duration of unipolar rectangular pulses have been the subject of several comprehensive studies [16–20].”
Background
Cited by
Arena, C. B., Sano, M. B., Rossmeisl, J. H., Caldwell, J. L., Garcia, P. A., Rylander, M. N., & Davalos, R. V. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-102 · Cited by 361
Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells
Varshney, M., & Li, Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.001 · Cited by 360
Kotnik, T., & Miklavčič, D. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.070771 · Cited by 318
Buckow, R., Ng, S., & Toepfl, S. (2013) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12026 · Cited by 216
Tutorial: Electroporation of cells in complex materials and tissue
Rems, L., & Miklavčič, D. (2016) · Journal of Applied Physics · doi:10.1063/1.4949264 · Cited by 180
Self-citation
Metadata
- Authors
- Kotnik, T., Pucihar, G., Reberšek, M., Miklavčič, D., & Mir, L. M.
- Venue
- Biochimica et Biophysica Acta (BBA) - Biomembranes
- Publisher
- Elsevier BV
- Published
- 2003-08
- Volume
- 1614
- Issue
- 2
- Pages
- 193-200
- ISSN
- 0005-2736 (ISSN-L)
- OpenAlex
- W2162635508
- Cited by
- 166
- References
- 38
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.