Time domain dielectric spectroscopy study of human cells
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical Properties of Tissue and Cell Suspensions
Schwan, H. P. (1957) · Advances in Biological and Medical Physics · doi:10.1016/b978-1-4832-3111-2.50008-0 · Cited by 1,620 · cited 2×
“The cell suspension spectra are known to show a so-called L-dispersion [1], which is observed in the frequency range of 100 kHz to 10 MHz and can be interpreted as the interface polarization.”
BackgroundDielectric constants of heterogeneous mixtures
Looyenga, H. (1965) · Physica · doi:10.1016/0031-8914(65)90045-5 · Cited by 1,263
Pethig, R., & Kell, D. B. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/8/001 · Cited by 796
Dielectric and electronic properties of biological materials
Pethig, R. (1979) · Cited by 707
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680
Pauly, H., & Schwan, H. P. (1959) · Zeitschrift für Naturforschung B · doi:10.1515/znb-1959-0213 · Cited by 406
Dielectric properties of mouse lymphocytes and erythrocytes
Asami, K., Takahashi, Y., & Takashima, S. (1989) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/0167-4889(89)90183-3 · Cited by 224 · cited 5×
“Another two ¢xed parameters were the dielectric permittivity of cytoplasm Ocp = 60 [8] and the dielectric permittivity of nucleoplasm Onp = 120.”
BackgroundMethodInfluentialDingwall, C., & Laskey, R. (1992) · Science · doi:10.1126/science.1439805 · Cited by 206 · cited 1×
“The nuclear envelope (NE) of eukaryotic cells is made up of two concentric membranes, the inner and the outer envelope membrane [34].”
Electrical Properties of Biopolymers and Membranes
Takashima, S. (1989) · Medical Entomology and Zoology · Cited by 203
Regulation of the sodium pump: how and why?
Rossier, B. C., Geering, K., & Kraehenbuhl, J. P. (1987) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(87)90235-0 · Cited by 163 · cited 1×
“It was the same in comparison to cells, which were kept in their growth medium, thus it implies that there were no very large changes in the intracellular ion composition [30].”
Result
Cited by
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Characterization of heterogeneous systems by dielectric spectroscopy
Asami, K. (2002) · Progress in Polymer Science · doi:10.1016/s0079-6700(02)00015-1 · Cited by 562
Dielectrophoresis in microfluidics technology
Çetin, B., & Li, D. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100167 · Cited by 411
Calcium bursts induced by nanosecond electric pulses
Vernier, P. T., Sun, Y., Marcu, L., Salemi, S., Craft, C. M., & Gundersen, M. A. (2003) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2003.08.140 · Cited by 400
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Nanoelectropulse-driven membrane perturbation and small molecule permeabilization
Vernier, P. T., Sun, Y., & Gundersen, M. A. (2006) · BMC Cell Biology · doi:10.1186/1471-2121-7-37 · Cited by 319
Kotnik, T., & Miklavčič, D. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.070771 · Cited by 318
Dielectric mixtures: electrical properties and modeling
Tuncer, E., Serdyuk, Y. V., & Gubanski, S. M. (2002) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2002.1038664 · Cited by 314
Tura, A., Maran, A., & Pacini, G. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2006.10.027 · Cited by 283
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Characterization of biological cells by dielectric spectroscopy
Asami, K. (2002) · Journal of Non-Crystalline Solids · doi:10.1016/s0022-3093(02)01110-9 · Cited by 252
Time domain dielectric spectroscopy study of biological systems
Feldman, Y., Ermolina, I., & Hayashi, Y. (2003) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2003.1237324 · Cited by 245
Self-citationThe Effects of Intense Submicrosecond Electrical Pulses on Cells
Deng, J., Schoenbach, K. H., Stephen Buescher, E., Hair, P. S., Fox, P. M., & Beebe, S. J. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75076-0 · Cited by 239
“…based on time domain dielectric spectroscopy of cell suspensions have yielded information on the electrical parameters of cellular substructures (Polevaya et al., 1999), cell models which take intracellular responses to external electric fields into account are still based on relatively…”
BackgroundRecent advances in noninvasive glucose monitoring
Chung, J., So, H., Choi, & Wong, T. K. S. (2012) · Medical Devices: Evidence and Research · doi:10.2147/mder.s28134 · Cited by 218
“14 In 2003, the company Pendragon Medical Ltd. (Zurich, Switzerland) developed a wrist-band-based glucose monitor called “Pendra.””
Capacitance cytometry: Measuring biological cells one by one
Sohn, L. L., Saleh, O. A., Facer, G. R., Beavis, A. J., Allan, R. S., & Notterman, D. A. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.200361297 · Cited by 205
Nanoelectropulse-Induced Phosphatidylserine Translocation
Thomas Vernier, P., Sun, Y., Marcu, L., Craft, C. M., & Gundersen, M. A. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.037945 · Cited by 193
“…electric pulses, and to be able to do so selectively for different cell types (Vernier et al., 2003a) depending on their dielectric properties (Polevaya et al., 1999) suggests the development of pulse exposure recipes (with pulse trains of varying amplitude, duration, and pattern), eventually…”
Background
Metadata
- Authors
- Polevaya, Y., Ermolina, I., Schlesinger, M., Ginzburg, B.-Z., & Feldman, Y.
- Venue
- Biochimica et Biophysica Acta (BBA) - Biomembranes
- Publisher
- Elsevier BV
- Published
- 1999-07
- Volume
- 1419
- Issue
- 2
- Pages
- 257-271
- ISSN
- 0005-2736 (ISSN-L)
- OpenAlex
- W2223822801
- Cited by
- 234
- References
- 18
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.