The DOI matches its Crossref record.
High-Resolution Imaging of Antibodies by Tapping-Mode Atomic Force Microscopy: Attractive and Repulsive Tip-Sample Interaction Regimes
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Force-induced conformational changes in PIEZO1
Lin, Y.-C., Guo, Y. R., Miyagi, A., Levring, J., MacKinnon, R., & Scheuring, S. (2019) · Nature · doi:10.1038/s41586-019-1499-2 · Cited by 433
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Rodrı́guez, T. R., & Garcı́a, R. (2004) · Applied Physics Letters · doi:10.1063/1.1642273 · Cited by 295
Self-citationMartin-Jimenez, D., Chacon, E., Tarazona, P., & Garcia, R. (2016) · Nature Communications · doi:10.1038/ncomms12164 · Cited by 198
Self-citationAtomic-scale mapping of hydrophobic layers on graphene and few-layer MoS2 and WSe2 in water
Uhlig, M. R., Martin-Jimenez, D., & Garcia, R. (2019) · Nature Communications · doi:10.1038/s41467-019-10740-w · Cited by 138
Metadata
- Authors
- San Paulo, A., & García, R.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2000-03
- Volume
- 78
- Issue
- 3
- Pages
- 1599-1605
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1978592866
- Cited by
- 286
- References
- 0
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Resolution Imaging of Antibodies by Tapping-Mode Atomic Force Microscopy: Attractive and Repulsive Tip-Sample Interaction Regimes. https://app.cochat.ai/papers/10.1016/s0006-3495(00)76712-9
- The paper
- San Paulo, A., & García, R. (2000). High-Resolution Imaging of Antibodies by Tapping-Mode Atomic Force Microscopy: Attractive and Repulsive Tip-Sample Interaction Regimes. Biophysical Journal. https://doi.org/10.1016/s0006-3495(00)76712-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.