Models of Motor-Assisted Transport of Intracellular Particles
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carslaw, H. S., & Jaeger, J. C. (1947) · International Linear Collider · Cited by 21,232
Tranter, C. J. (1959) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(59)90029-8 · Cited by 18,388
Stochastic Problems in Physics and Astronomy
Chandrasekhar, S. (1943) · Reviews of Modern Physics · doi:10.1103/revmodphys.15.1 · Cited by 8,470 · cited 1×
“In the limit of many pauses the distribution of the net displacement can be obtained from the central limit theorem, even though the length of each excursion on filaments is itself a random variable controlled by the kinetics of detachment (Chandrasekhar, 1943).”
BackgroundVetterling, W. T., Teukolsky, S. A., Press, W. H., & Flannery, B. P. (1988) · Cited by 7,701
Press, W. H., Teukolsky, S. L. A., Flannery, B. P., & Vetterling, W. T. (1990) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 6,980
Identification of a novel force-generating protein, kinesin, involved in microtubule-based motility
VALE, R., REESE, T., & SHEETZ, M. (1985) · Cell · doi:10.1016/s0092-8674(85)80099-4 · Cited by 1,993
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910 · cited 2×
“Assays where a single motor molecule moves an attached bead (Svoboda et al., 1993) suggest that kinetic fluctuations in the number of motors bound to a filament should be less severe for highly processive motors such as kinesin or myosin V, where a single dimeric motor may stay within a zone of weak interaction around…”
BackgroundForce and velocity measured for single kinesin molecules
Svoboda, K., & Block, S. M. (1994) · Cell · doi:10.1016/0092-8674(94)90060-4 · Cited by 909 · cited 2×
“…speeds on an isolated filament are expected to be load-independent for micron-sized particles and normal cytoplasm; the tension/velocity coefficient for viscous drag is two orders of magnitude smaller than the slope of the load-velocity line, namely 5 pNz s/mm for kinesin (Svoboda and Block, 1994).”
BackgroundMyosin-V is a processive actin-based motor
Mehta, A. D., Rock, R. S., Rief, M., Spudich, J. A., Mooseker, M. S., & Cheney, R. E. (1999) · Nature · doi:10.1038/23072 · Cited by 786 · cited 2×
“4 mm/s have been observed (Cheney et al., 1993; Evans et al., 1998; Wolenski et al., 1995; Mehta et al., 1999).”
BackgroundInfluentialAxonal transport of mitochondria along microtubules and F-actin in living vertebrate neurons.
Morris, R. L., & Hollenbeck, P. J. (1995) · The Journal of cell biology · doi:10.1083/jcb.131.5.1315 · Cited by 541 · cited 5×
“…particles diffusing freely or attached to moving structures, and particles trapped on static structures, which could also be motor-filaments (Adams and Bray, 1983; Allen et al., 1982; Bridgman, 1999; Breuer et al., 1988; Cooper and Smith, 1974; Koles et al., 1982; Morris and Hollenbeck, 1995).”
BackgroundInfluential
Cited by
Stochastic models of intracellular transport
Bressloff, P. C., & Newby, J. M. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.135 · Cited by 629
Bidirectional transport along microtubules
Welte, M. A. (2004) · Current Biology · doi:10.1016/j.cub.2004.06.045 · Cited by 577
“Although the difference (p – m) gives a qualitative measure of net directionality, the exact rate of transport depends also on the speed of runs, the time from reversal to reversal, and the frequency of pauses [19,92,93].”
Quantitative four-dimensional tracking of cytoplasmic and nuclear HIV-1 complexes
Arhel, N., Genovesio, A., Kim, K.-A., Miko, S., Perret, E., Olivo-Marin, J.-C., Shorte, S., & Charneau, P. (2006) · Nature Methods · doi:10.1038/nmeth928 · Cited by 304
Drosophila Miro Is Required for Both Anterograde and Retrograde Axonal Mitochondrial Transport
Russo, G. J., Louie, K., Wellington, A., Macleod, G. T., Hu, F., Panchumarthi, S., & Zinsmaier, K. E. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.5417-08.2009 · Cited by 217
“For our analysis, we followed commonly used definitions (Hollen- beck, 1996; Welte et al., 1998; Smith and Simmons, 2001; Maly, 2002; Welte, 2004).”
MethodFriction and energy dissipation mechanisms in adsorbed molecules and molecularly thin films
Krim, J. (2012) · Advances in Physics · doi:10.1080/00018732.2012.706401 · Cited by 201
van de Meent, J.-W., Bronson, J. E., Wiggins, C. H., & Gonzalez, R. L. (2014) · Biophysical Journal · doi:10.1016/j.bpj.2013.12.055 · Cited by 183
A physical perspective on cytoplasmic streaming
Goldstein, R. E., & van de Meent, J.-W. (2015) · Interface Focus · doi:10.1098/rsfs.2015.0030 · Cited by 170
A Model for Intracellular Trafficking of Adenoviral Vectors
Dinh, A.-T., Theofanous, T., & Mitragotri, S. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.059477 · Cited by 76
Randolph Byers, H., Maheshwary, S., Amodeo, D. M., & Dykstra, S. G. (2003) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2003.12481.x · Cited by 63
Metadata
- Authors
- Smith, D. A., & Simmons, R. M.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2001-01
- Volume
- 80
- Issue
- 1
- Pages
- 45-68
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2084296558
- Cited by
- 172
- References
- 60
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.