Holding Forces of Single-Particle Dielectrophoretic Traps
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786 · cited 1×
“4), to model plastic beads, or a dielectric shell, to model cells, using expressions from the literature (Jones, 1995).”
MethodBiological Applications of Optical Forces
Svoboda, K., & Block, S. M. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.001335 · Cited by 1,792
Electrohydrodynamics: A Review of the Role of Interfacial Shear Stresses
Melcher, J. R., & Taylor, G. I. (1969) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.01.010169.000551 · Cited by 1,339 · cited 1×
“EHD flows, induced by the interaction between either thermally generated or double-layer charge with electric fields in fluids (Ramos et al., 1998; Melcher and Taylor, 1969; Melcher, 1981), can impart either confining or destabilizing forces.”
BackgroundAc electrokinetics: a review of forces in microelectrode structures
Ramos, A., Morgan, H., Green, N. G., & Castellanos, A. (1998) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/31/18/021 · Cited by 1,233 · cited 3×
“The type of force is dictated by the origin of the charge (thermal or double-layer) and the applied frequency relative to the relaxation frequency of the medium (which has the form /⑀) (Ramos et al., 1998, 1999).”
BackgroundLewis, T. J. (1982) · Physics Bulletin · doi:10.1088/0031-9112/33/8/034 · Cited by 646
Dielectrophoretic separation of cancer cells from blood
Gascoyne, P. R. C., Wang, X.-B., Huang, Y., & Becker, F. F. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.585856 · Cited by 406
Cheng, J., Sheldon, E. L., Wu, L., Uribe, A., Gerrue, L. O., Carrino, J., Heller, M. J., & O'Connell, J. P. (1998) · Nature Biotechnology · doi:10.1038/nbt0698-541 · Cited by 347 · cited 1×
“The diversity of applications includes particle separation by differential dielectric properties (Gascoyne et al., 1997; Cheng et al., 1998; Markx et al., 1994; Talary et al., 1995), force calibrations of optical tweezers (Fuhr et al., 1998), measurement of bacterial flagellar thrust (Hughes and…”
BackgroundA 3-D microelectrode system for handling and caging single cells and particles
Müller, T., Gradl, G., Howitz, S., Shirley, S., Schnelle, T., & Fuhr, G. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00006-8 · Cited by 242 · cited 3×
“Recent work (Schnelle et al., 1999b; Muller et al., 1999) has even started to concentrate on the interaction between DEP and HD forces, in their case determining the flow needed to break through a DEP barrier, similar to our case.”
BackgroundResultLinear and nonlinear electrode polarization and biological materials
Schwan, H. P. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368531 · Cited by 233
Multipolar dielectrophoretic force calculation
Washizu, M., & Jones, T. B. (1994) · Journal of Electrostatics · doi:10.1016/0304-3886(94)90053-1 · Cited by 141 · cited 2×
“In the mid-nineties Washizu and Jones (Jones and Washizu, 1996; Washizu and Jones, 1994, 1996) developed a computationally accessible approach to calculating higher-order DEP forces, which we have implemented into our model (see Appendix).”
MethodGreen, N. G., & Morgan, H. (1998) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/31/7/002 · Cited by 138 · cited 1×
“First, flows not predicted by DEP theory alone (and attributed to EHD phenomena) have been observed repeatedly by DEP researchers working on microscale electrodes (Fuhr et al., 1992b; Ramos et al., 1998, 1999; Muller et al., 1996; Green and Morgan, 1998).”
BackgroundMultipolar dielectrophoretic and electrorotation theory
Jones, T. B., & Washizu, M. (1996) · Journal of Electrostatics · doi:10.1016/0304-3886(96)00006-x · Cited by 132 · cited 5×
“Other researchers testing the theory have used particle levitation (Kaler and Jones, 1990; Hartley et al., 1999), flow-induced particle displacement in DEP traps (Fuhr et al., 1998; Muller et al., 1999), and particle velocity measurements in DEP force fields (Cruz and Garcia-Diego, 1997).”
MethodInfluentialDielectrophoretic trapping of single sub-micrometre scale bioparticles
Hughes, M. P., & Morgan, H. (1998) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/31/17/020 · Cited by 132 · cited 1×
“First, flows not predicted by DEP theory alone (and attributed to EHD phenomena) have been observed repeatedly by DEP researchers working on microscale electrodes (Fuhr et al., 1992b; Ramos et al., 1998, 1999; Muller et al., 1996; Green and Morgan, 1998).”
BackgroundPaired microelectrode system: dielectrophoretic particle sorting and force calibration
Schnelle, T., Müller, T., Gradl, G., et al. (1999) · Journal of Electrostatics · doi:10.1016/s0304-3886(99)00032-7 · Cited by 100 · cited 3×
“Recent work (Schnelle et al., 1999b; Muller et al., 1999) has even started to concentrate on the interaction between DEP and HD forces, in their case determining the flow needed to break through a DEP barrier, similar to our case.”
BackgroundResultThe influence of higher moments on particle behaviour in dielectrophoretic field cages
Schnelle, T., Müller, T., Fiedler, S., & Führ, G. (1999) · Journal of Electrostatics · doi:10.1016/s0304-3886(98)00055-2 · Cited by 87
Ramos, A., Morgan, H., Green, N. G., et al. (1999) · Journal of Electrostatics · doi:10.1016/s0304-3886(99)00031-5 · Cited by 77 · cited 4×
“First, flows not predicted by DEP theory alone (and attributed to EHD phenomena) have been observed repeatedly by DEP researchers working on microscale electrodes (Fuhr et al., 1992b; Ramos et al., 1998, 1999; Muller et al., 1996; Green and Morgan, 1998).”
BackgroundInfluentialGeneralized multipolar dielectrophoretic force and electrorotational torque calculation
Washizu, M., & Jones, T. B. (1996) · Journal of Electrostatics · doi:10.1016/s0304-3886(96)00025-3 · Cited by 51 · cited 2×
“In the mid-nineties Washizu and Jones (Jones and Washizu, 1996; Washizu and Jones, 1994, 1996) developed a computationally accessible approach to calculating higher-order DEP forces, which we have implemented into our model (see Appendix).”
MethodMeasurement of Bacterial Flagellar Thrust by Negative Dielectrophoresis
Hughes, M. P., & Morgan, H. (1999) · Biotechnology Progress · doi:10.1021/bp990019+ · Cited by 45 · cited 1×
“…Markx et al., 1994; Talary et al., 1995), force calibrations of optical tweezers (Fuhr et al., 1998), measurement of bacterial flagellar thrust (Hughes and Morgan, 1999), three-dimensional positive-DEP traps (Suehiro and Pethig, 1998), and extraction of electrical properties or validation of…”
BackgroundQuadrupole levitation of microscopic dielectric particles
Hartley, L., Kaler, K. V. I. S., & Paul, R. (1999) · Journal of Electrostatics · doi:10.1016/s0304-3886(98)00061-8 · Cited by 27 · cited 3×
“Including the quadrupole term accurately models the problem, because it correctly accounts for the levitation force in quadrupole traps, in agreement with previous work (Washizu et al., 1993; Hartley et al., 1999; Schnelle et al., 1999a).”
BackgroundResultDielectrophoretic force measurements in yeast cells by the Stokes method
Cruz, J. M., & García-Diego, F.-J. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1997.626338 · Cited by 7 · cited 1×
“Other researchers testing the theory have used particle levitation (Kaler and Jones, 1990; Hartley et al., 1999), flow-induced particle displacement in DEP traps (Fuhr et al., 1998; Muller et al., 1999), and particle velocity measurements in DEP force fields (Cruz and Garcia-Diego, 1997).”
Background
Cited by
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Self-citationParticle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
BioMEMS: state-of-the-art in detection, opportunities and prospects
Bashir, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.03.002 · Cited by 462
New directions in single-molecule imaging and analysis
Moerner, W. E. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610081104 · Cited by 440
A Microfabrication-Based Dynamic Array Cytometer
Voldman, J., Gray, M. L., Toner, M., & Schmidt, M. A. (2002) · Analytical Chemistry · doi:10.1021/ac0256235 · Cited by 328
Self-citation
Metadata
- Authors
- Voldman, J., Braff, R. A., Toner, M., Gray, M. L., & Schmidt, M. A.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2001-01
- Volume
- 80
- Issue
- 1
- Pages
- 531-542
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1975536891
- Cited by
- 195
- References
- 20
- FWCI
- 8.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.