The DOI matches its Crossref record.
Near-Wall μ-PIV Reveals a Hydrodynamically Relevant Endothelial Surface Layer in Venules In Vivo
Open accessAbstract
High-resolution near-wall fluorescent microparticle image velocimetry (micro-PIV) was used in mouse cremaster muscle venules in vivo to measure velocity profiles in the red cell-depleted plasma layer near the endothelial lining. micro-PIV data of the instantaneous translational speeds and radial positions of fluorescently labeled microspheres (0.47 microm) in an optical section through the midsagittal plane of each vessel were used to determine fluid particle translational speeds. Regression of a linear velocity distribution based on near-wall fluid-particle speeds consistently revealed a negative intercept when extrapolated to the vessel wall. Based on a detailed three-dimensional analysis of the local fluid dynamics, we estimate a mean effective thickness of approximately 0.33 micro m for an impermeable endothelial surface layer or approximately 0.44 micro m assuming the lowest hydraulic resistivity of the layer that is consistent with the observed particle motions. The extent of plasma flow retardation through the layer required to be consistent with our micro-PIV data results in near complete attenuation of fluid shear stress on the endothelial-cell surface. These findings confirm the presence of a hydrodynamically effective endothelial surface layer, and emphasize the need to revise previous concepts of leukocyte adhesion, stress transmission to vascular endothelium, permeability, and mechanotransduction mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Monitoring of Blood Vessels and Tissues by a Population of Monocytes with Patrolling Behavior
Auffray, C., Fogg, D., Garfa, M., Elain, G., Join-Lambert, O., Kayal, S., Sarnacki, S., Cumano, A., Lauvau, G., & Geissmann, F. (2007) · Science · doi:10.1126/science.1142883 · Cited by 1,973
Mechanotransduction in vascular physiology and atherogenesis
Hahn, C., & Schwartz, M. A. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2596 · Cited by 1,211
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Self-citationSchmidt, E. P., Yang, Y., Janssen, W. J., Gandjeva, A., Perez, M. J., Barthel, L., Zemans, R. L., Bowman, J. C., Koyanagi, D. E., Yunt, Z. X., et al. (2012) · Nature Medicine · doi:10.1038/nm.2843 · Cited by 848
MICROCIRCULATION AND HEMORHEOLOGY
Popel, A. S., & Johnson, P. C. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.37.042604.133933 · Cited by 831
Metadata
- Authors
- Smith, M. L., Long, D. S., Damiano, E. R., & Ley, K.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 85
- Issue
- 1
- Pages
- 637-645
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2171911820
- Cited by
- 214
- References
- 0
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-Wall μ-PIV Reveals a Hydrodynamically Relevant Endothelial Surface Layer in Venules In Vivo. https://app.cochat.ai/papers/10.1016/s0006-3495(03)74507-x
- The paper
- Smith, M. L., Long, D. S., Damiano, E. R., & Ley, K. (2003). Near-Wall μ-PIV Reveals a Hydrodynamically Relevant Endothelial Surface Layer in Venules In Vivo. Biophysical Journal. https://doi.org/10.1016/s0006-3495(03)74507-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.