Near-Wall μ-PIV Reveals a Hydrodynamically Relevant Endothelial Surface Layer in Venules In Vivo
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
High-resolution near-wall fluorescent microparticle image velocimetry (micro-PIV) was used in mouse cremaster muscle venules in vivo to measure velocity profiles in the red cell-depleted plasma layer near the endothelial lining. micro-PIV data of the instantaneous translational speeds and radial positions of fluorescently labeled microspheres (0.47 microm) in an optical section through the midsagittal plane of each vessel were used to determine fluid particle translational speeds. Regression of a linear velocity distribution based on near-wall fluid-particle speeds consistently revealed a negative intercept when extrapolated to the vessel wall. Based on a detailed three-dimensional analysis of the local fluid dynamics, we estimate a mean effective thickness of approximately 0.33 micro m for an impermeable endothelial surface layer or approximately 0.44 micro m assuming the lowest hydraulic resistivity of the layer that is consistent with the observed particle motions. The extent of plasma flow retardation through the layer required to be consistent with our micro-PIV data results in near complete attenuation of fluid shear stress on the endothelial-cell surface. These findings confirm the presence of a hydrodynamically effective endothelial surface layer, and emphasize the need to revise previous concepts of leukocyte adhesion, stress transmission to vascular endothelium, permeability, and mechanotransduction mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Traffic Signals on Endothelium for Lymphocyte Recirculation and Leukocyte Emigration
Springer, T. A. (1995) · Annual Review of Physiology · doi:10.1146/annurev.ph.57.030195.004143 · Cited by 1,496 · cited 1×
“Rolling leukocytes attach to blood vessel walls using molecules that extend 20–50 nm above the plasma membrane (Springer, 1995).”
BackgroundPries, A. R., Secomb, T. W., & Gaehtgens, P. (2000) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240000307 · Cited by 898 · cited 2×
“The glycocalyx is a layer of membrane-bound macromolecules (Pries et al., 2000) with a thickness estimated from electron microscopy studies to be ;100 nm (Haldenby et al.”
BackgroundResistance to blood flow in microvessels in vivo.
Pries, A. R., Secomb, T. W., Gessner, T., Sperandio, M. B., Gross, J. F., & Gaehtgens, P. (1994) · Circulation Research · doi:10.1161/01.res.75.5.904 · Cited by 616
Vink, H., & Duling, B. R. (1996) · Circulation Research · doi:10.1161/01.res.79.3.581 · Cited by 615 · cited 7×
“Based on a method published earlier (Vink and Duling, 1996), FITC-dx 70 (Sigma Chemical St.”
BackgroundMethodResultInfluentialSequential contribution of L- and P-selectin to leukocyte rolling in vivo.
Ley, K., Bullard, D. C., Arbonés, M. L., Bosse, R., Vestweber, D., Tedder, T. F., & Beaudet, A. L. (1995) · The Journal of experimental medicine · doi:10.1084/jem.181.2.669 · Cited by 574 · cited 1×
“described (Baez, 1973; Ley et al., 1995).”
Self-citationBlood flow in microvascular networks. Experiments and simulation.
Pries, A. R., Secomb, T. W., Gaehtgens, P., & Gross, J. F. (1990) · Circulation Research · doi:10.1161/01.res.67.4.826 · Cited by 566
An open cremaster muscle preparation for the study of blood vessels by in vivo microscopy
Baez, S. (1973) · Microvascular Research · doi:10.1016/0026-2862(73)90054-x · Cited by 498 · cited 1×
“described (Baez, 1973; Ley et al., 1995).”
Universal GFP reporter for the study of vascular development
Motoike, T., Loughna, S., Perens, E., Roman, B. L., Liao, W., Chau, T. C., Richardson, C. D., Kawate, T., Kuno, J., Weinstein, B. M., et al. (2000) · genesis · doi:10.1002/1526-968x(200010)28:2<75::aid-gene50>3.0.co;2-s · Cited by 451 · cited 1×
“Tie2 green fluorescent protein (GFP) transgenic mice were obtained from established colonies derived from founders as described (Motoike et al., 2000).”
MethodPermeation of the luminal capillary glycocalyx is determined by hyaluronan
Henry, C. B. S., & Duling, B. R. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.2.h508 · Cited by 426 · cited 3×
“, 1997) after infusion of heparinase, an enzyme that appears to partially degrade the ESL (Desjardins and Duling, 1990; Henry and Duling, 1999).”
BackgroundMethod
Cited by
Monitoring of Blood Vessels and Tissues by a Population of Monocytes with Patrolling Behavior
Auffray, C., Fogg, D., Garfa, M., Elain, G., Join-Lambert, O., Kayal, S., Sarnacki, S., Cumano, A., Lauvau, G., & Geissmann, F. (2007) · Science · doi:10.1126/science.1142883 · Cited by 1,973
Mechanotransduction in vascular physiology and atherogenesis
Hahn, C., & Schwartz, M. A. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2596 · Cited by 1,211
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Self-citationSchmidt, E. P., Yang, Y., Janssen, W. J., Gandjeva, A., Perez, M. J., Barthel, L., Zemans, R. L., Bowman, J. C., Koyanagi, D. E., Yunt, Z. X., et al. (2012) · Nature Medicine · doi:10.1038/nm.2843 · Cited by 848
MICROCIRCULATION AND HEMORHEOLOGY
Popel, A. S., & Johnson, P. C. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.37.042604.133933 · Cited by 831
Mechanisms of Mechanotransduction
Orr, A. W., Helmke, B. P., Blackman, B. R., & Schwartz, M. A. (2006) · Developmental Cell · doi:10.1016/j.devcel.2005.12.006 · Cited by 798
Integrins in Mechanotransduction
Katsumi, A., Orr, A. W., Tzima, E., & Schwartz, M. A. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.r300038200 · Cited by 723
Reneman, R. S., Arts, T., & Hoeks, A. P. G. (2006) · Journal of Vascular Research · doi:10.1159/000091648 · Cited by 431
Micro-Particle Image Velocimetry (µPIV): Recent developments, applications, and guidelines
Lindken, R., Rossi, M., Große, S., & Westerweel, J. (2009) · Lab on a Chip · doi:10.1039/b906558j · Cited by 387
Microvascular blood viscosity in vivo and the endothelial surface layer
Pries, A. R., & Secomb, T. W. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00297.2005 · Cited by 349
Derangement of the endothelial glycocalyx in sepsis
Iba, T., & Levy, J. H. (2019) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14371 · Cited by 322
No scavenging and the hypertensive effect of hemoglobin-based blood substitutes
Olson, J. S., Foley, E. W., Rogge, C., Tsai, A.-L., Doyle, M. P., & Lemon, D. D. (2004) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2003.11.030 · Cited by 308
Ouedraogo, R., Gong, Y., Berzins, B., Wu, X., Mahadev, K., Hough, K., Chan, L., Goldstein, B. J., & Scalia, R. (2007) · Journal of Clinical Investigation · doi:10.1172/jci29623 · Cited by 264
Modulation of Endothelial Glycocalyx Structure under Inflammatory Conditions
Kolářová, H., Ambrůzová, B., Švihálková Šindlerová, L., Klinke, A., & Kubala, L. (2014) · Mediators of Inflammation · doi:10.1155/2014/694312 · Cited by 257
Sarkar, D., Spencer, J. A., Phillips, J. A., Zhao, W., Schafer, S., Spelke, D. P., Mortensen, L. J., Ruiz, J. P., Vemula, P. K., Sridharan, R., et al. (2011) · Blood · doi:10.1182/blood-2010-10-311464 · Cited by 229
van Golen, R. F., van Gulik, T. M., & Heger, M. (2012) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2012.01.013 · Cited by 221
Chappell, D., Jacob, M., Paul, O., Rehm, M., Welsch, U., Stoeckelhuber, M., Conzen, P., & Becker, B. F. (2009) · Circulation Research · doi:10.1161/circresaha.108.187831 · Cited by 218
Platelets Guide Leukocytes to Their Sites of Extravasation
Zuchtriegel, G., Uhl, B., Puhr-Westerheide, D., Pörnbacher, M., Lauber, K., Krombach, F., & Reichel, C. A. (2016) · PLOS Biology · doi:10.1371/journal.pbio.1002459 · Cited by 217
Blood Flow in Microvascular Networks
Pries, A. R., & Secomb, T. W. (2008) · Microcirculation · doi:10.1016/b978-0-12-374530-9.00001-2 · Cited by 213
Long, D. S., Smith, M. L., Pries, A. R., Ley, K., & Damiano, E. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402937101 · Cited by 210
Self-citationEndothelial Glycocalyx: Sweet Shield of Blood Vessels
VanTeeffelen, J. W., Brands, J., Stroes, E. S., & Vink, H. (2007) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2007.02.002 · Cited by 207
“Intravital microscopic studies of the microcirculation in cremaster tissue of rodents indicate that the glycocalyx excludes flowing red blood cells and greatly retards plasma flow under control conditions (Smith et al. 2003; Vink and Duling 1996; Vink and Duling 2000).”
BackgroundRegulation and function of endothelial glycocalyx layer in vascular diseases
Sieve, I., Münster-Kühnel, A. K., & Hilfiker-Kleiner, D. (2018) · Vascular Pharmacology · doi:10.1016/j.vph.2017.09.002 · Cited by 199
In vivo micro particle image velocimetry measurements of blood-plasma in the embryonic avian heart
Vennemann, P., Kiger, K. T., Lindken, R., Groenendijk, B. C. W., Stekelenburg-de Vos, S., ten Hagen, T. L. M., Ursem, N. T. C., Poelmann, R. E., Westerweel, J., & Hierck, B. P. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.03.015 · Cited by 198
“Smith et al. (2003) refined this method by injecting fluorescent microspheres (500 nm diameter) into the mouse cremaster muscle venules, although only the velocities of up to four particles at irregular distances above the glycocalyx layer were used to estimate the velocity profile.”
Lipowsky, H. H. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0427-x · Cited by 180
Mechanosensing at the Vascular Interface
Tarbell, J. M., Simon, S. I., & Curry, F.-R. E. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104908 · Cited by 180
Dogné, S., Flamion, B., & Caron, N. (2018) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.118.310839 · Cited by 177
The Recovery Time Course of the Endothelial Cell Glycocalyx In Vivo and Its Implications In Vitro
Potter, D. R., Jiang, J., & Damiano, E. R. (2009) · Circulation Research · doi:10.1161/circresaha.108.191585 · Cited by 176
Self-citationFu, B. M., & Tarbell, J. M. (2013) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.1211 · Cited by 175
Temporal and spatial variations of cell-free layer width in arterioles
Kim, S., Kong, R. L., Popel, A. S., Intaglietta, M., & Johnson, P. C. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01090.2006 · Cited by 174
“We followed criteria used in previous studies (13, 42, 48) in determining vessel wall location.”
MethodThe Hydrodynamically Relevant Endothelial Cell Glycocalyx Observed In Vivo Is Absent In Vitro
Potter, D. R., & Damiano, E. R. (2008) · Circulation Research · doi:10.1161/circresaha.107.160226 · Cited by 173
Self-citationThe cell-free layer in microvascular blood flow
Kim, S., Ong, P. K., Yalcin, O., Intaglietta, M., & Johnson, P. C. (2009) · Biorheology · doi:10.3233/bir-2009-0530 · Cited by 159
“The existence of the glycocalyx layer of ∼ 0.5 µm in thickness is well established in capillaries and venules [46].”
Influential
Metadata
- Authors
- Smith, M. L., Long, D. S., Damiano, E. R., & Ley, K.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 85
- Issue
- 1
- Pages
- 637-645
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2171911820
- Cited by
- 214
- References
- 27
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.