The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cascades of Transient Pores in Giant Vesicles: Line Tension and Transport
Open accessAbstract
Under ordinary circumstances, the membrane tension of a giant unilamellar vesicle is essentially nil. Using visible light, we stretch the vesicles, increasing the membrane tension until the membrane responds by the sudden opening of a large pore (several micrometers in size). Only a single pore is observed at a time in a given vesicle. However, a cascade of transient pores appear, up to 30-40 in succession, in the same vesicle. These pores are transient: they reseal within a few seconds as the inner liquid leaks out. The membrane tension, which is the driving force for pore opening, is relaxed with the opening of a pore and the leakage of the inner liquid; the line tension of the pore's edge is then able to drive the closure of a pore. We use fluorescent membrane probes and real-time videomicroscopy to study the dynamics of the pores. These can be visualized only if the vesicles are prepared in a viscous solution to slow down the leakout of the internal liquid. From measurements of the closure velocity of the pores, we are able to infer the line tension,. We have studied the effect of the shape of inclusion molecules on. Cholesterol, which can be modeled as an inverted cone-shaped molecule, increases the line tension when incorporated into the bilayers. Conversely, addition of cone-shaped detergents reduces. The effect of some detergents can be dramatic, reducing by two orders of magnitude, and increasing pore lifetimes up to several minutes. We give some examples of transport through transient pores and present a rough measurement of the leakout velocity of the inner liquid through a pore. We discuss how our results can be extended to less viscous aqueous solutions which are more relevant for biological systems and biotechnological applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The "Stealth" Liposome: A Prototypical Biomaterial
Lasic, D. D., & Needham, D. (1995) · Chemical Reviews · doi:10.1021/cr00040a001 · Cited by 416
Cited by
The biophysics and cell biology of lipid droplets
Thiam, A. R., Farese Jr, R. V., & Walther, T. C. (2013) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3699 · Cited by 986
Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts
Stewart, M. P., Langer, R., & Jensen, K. F. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00678 · Cited by 747
Recent developments in the field of bending rigidity measurements on membranes
Dimova, R. (2014) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2014.03.003 · Cited by 503
Octanol-assisted liposome assembly on chip
Deshpande, S., Caspi, Y., Meijering, A. E. C., & Dekker, C. (2016) · Nature Communications · doi:10.1038/ncomms10447 · Cited by 363
Double Emulsion Templated Monodisperse Phospholipid Vesicles
Shum, H. C., Lee, D., Yoon, I., Kodger, T., & Weitz, D. A. (2008) · Langmuir · doi:10.1021/la801833a · Cited by 362
Metadata
- Authors
- Karatekin, E., Sandre, O., Guitouni, H., Borghi, N., Puech, P.-H., & Brochard-Wyart, F.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2003-03
- Volume
- 84
- Issue
- 3
- Pages
- 1734-1749
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2087776349
- Cited by
- 416
- References
- 1
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cascades of Transient Pores in Giant Vesicles: Line Tension and Transport. https://app.cochat.ai/papers/10.1016/s0006-3495(03)74981-9
- The paper
- Karatekin, E., Sandre, O., Guitouni, H., Borghi, N., Puech, P.-H., & Brochard-Wyart, F. (2003). Cascades of Transient Pores in Giant Vesicles: Line Tension and Transport. Biophysical Journal. https://doi.org/10.1016/s0006-3495(03)74981-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.