Transient Response in a Dendritic Neuron Model for Current Injected at One Branch
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Mathematical expressions are obtained for the response function corresponding to an instantaneous pulse of current injected to a single dendritic branch in a branched dendritic neuron model. The theoretical model assumes passive membrane properties and the equivalent cylinder constraint on branch diameters. The response function when used in a convolution formula enables one to compute the voltage transient at any specified point in the dendritic tree for an arbitrary current injection at a given input location. A particular numerical example, for a brief current injection at a branch terminal, illustrates the attenuation and delay characteristics of the depolarization peak as it spreads throughout the neuron model. In contrast to the severe attenuation of voltage transients from branch input sites to the soma, the fraction of total input charge actually delivered to the soma and other trees is calculated to be about one-half. This fraction is independent of the input time course. Other numerical examples, which compare a branch terminal input site with a soma input site, demonstrate that, for a given transient current injection, the peak depolarization is not proportional to the input resistance at the injection site and, for a given synaptic conductance transient, the effective synaptic driving potential can be significantly reduced, resulting in less synaptic current flow and charge, for a branch input site. Also, for the synaptic case, the two inputs are compared on the basis of the excitatory post-synaptic potential (EPSP) seen at the soma and the total charge delivered to the soma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An analysis of the end‐plate potential recorded with an intra‐cellular electrode
Fatt, P., & Katz, B. (1951) · The Journal of Physiology · doi:10.1113/jphysiol.1951.sp004675 · Cited by 1,400
Rall, W. (1967) · Journal of Neurophysiology · doi:10.1152/jn.1967.30.5.1138 · Cited by 992
Self-citationTime Constants and Electrotonic Length of Membrane Cylinders and Neurons
Rall, W. (1969) · Biophysical Journal · doi:10.1016/s0006-3495(69)86467-2 · Cited by 751
Self-citationTheory of Physiological Properties of Dendrites
Rall, W. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb54120.x · Cited by 594
Self-citationOn the factors which determine the amplitude of the ‘miniature end‐plate potential’
Katz, B., & Thesleff, S. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005811 · Cited by 465
Branch Input Resistance and Steady Attenuation for Input to One Branch of a Dendritic Neuron Model
Rall, W., & Rinzel, J. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86014-x · Cited by 352
Self-citationA study of spontaneous miniature potentials in spinal motoneurones
Katz, B., & Miledi, R. (1963) · The Journal of Physiology · doi:10.1113/jphysiol.1963.sp007199 · Cited by 327
Membrane potential transients and membrane time constant of motoneurons
Rall, W. (1960) · Experimental Neurology · doi:10.1016/0014-4886(60)90029-7 · Cited by 295
Self-citationComposite nature of the monosynaptic excitatory postsynaptic potential.
Burke, R. E. (1967) · Journal of Neurophysiology · doi:10.1152/jn.1967.30.5.1114 · Cited by 204
Barrett, J. N., & Crill, W. E. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010571 · Cited by 187
Iansek, R., & Redman, S. J. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010366 · Cited by 147
The attenuation of passively propagating dendritic potentials in a motoneurone cable model
Redman, S. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010365 · Cited by 64
Barnwell, G. M., & Cerimele, B. J. (1972) · Kybernetik · doi:10.1007/bf00290513 · Cited by 5
Cited by
Core Conductor Theory and Cable Properties of Neurons
Rall, W. (1977) · Comprehensive Physiology · doi:10.1002/cphy.cp010103 · Cited by 767
Self-citationDendritic integration of excitatory synaptic input
Magee, J. C. (2000) · Nature reviews. Neuroscience · doi:10.1038/35044552 · Cited by 737
“It has been shown both in multicompartmental computer models and in dendritic recordings that the local input resistance for a transient event increases, whereas local capacitance decreases, with distance from the som”
BackgroundA functional microcircuit for cat visual cortex
Douglas, R. J., & Martin, K. A. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018733 · Cited by 736
Somatic EPSP amplitude is independent of synapse location in hippocampal pyramidal neurons
Magee, J. C., & Cook, E. P. (2000) · Nature Neuroscience · doi:10.1038/78800 · Cited by 647
Dendritic Ih normalizes temporal summation in hippocampal CA1 neurons
Magee, J. C. (1999) · Nature Neuroscience · doi:10.1038/9158 · Cited by 617
Metadata
- Authors
- Rinzel, J., & Rall, W.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1974-10
- Volume
- 14
- Issue
- 10
- Pages
- 759-790
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1967038391
- Cited by
- 289
- References
- 13
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.