Multiple site optical recording of transmembrane voltage (MSORTV) in patterned growth heart cell cultures: assessing electrical behavior, with microsecond resolution, on a cellular and subcellular scale
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
We have applied multiple site optical recording of transmembrane voltage (MSORTV) to patterned growth cultures of heart cells to analyze the effect of geometry per se on impulse propagation in excitable tissue, with cellular and subcellular resolution. Extensive dye screening led to the choice of di-8-ANEPPS as the most suitable voltage-sensitive dye for this application; it is internalized slowly and permits optical recording with signal-to-noise ratios as high as 40:1 (measured peak-to-peak) and average fractional fluorescence changes of 15% per 100 mV. Using a x 100 objective and a fast data acquisition system, we could resolve impulse propagation on a microscopic scale (15 microns) with high temporal resolution (uncertainty of +/- 5 microseconds). We could observe the decrease in conduction velocity of an impulse propagating along a narrow cell strand as it enters a region of abrupt expansion, and we could explain this phenomenon in terms of the micro-architecture of the tissue. In contrast with the elongated and aligned cells forming the narrow strands, the cells forming the expansions were aligned at random and presented 2.5 times as many cell-to-cell appositions per unit length. If the decrease in conduction velocity results entirely from this increased number of cell-to-cell boundaries per unit length, the mean activation delay introduced by each boundary can be estimated to be 70 microseconds. Using this novel experimental system, we could also demonstrate the electrical coupling of fibroblasts and endotheloid cells to myocytes in culture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Total Excitation of the Isolated Human Heart
DURRER, D., VAN DAM, R. T., FREUD, G. E., JANSE, M. J., MEIJLER, F. L., & ARZBAECHER, R. C. (1970) · Circulation · doi:10.1161/01.cir.41.6.899 · Cited by 1,777
Spiral waves of excitation underlie reentrant activity in isolated cardiac muscle.
Pertsov, A. M., Davidenko, J. M., Salomonsz, R., Baxter, W. T., & Jalife, J. (1993) · Circulation Research · doi:10.1161/01.res.72.3.631 · Cited by 619
Optical imaging of neuronal activity.
Grinvald, A., Frostig, R. D., Lieke, E., & Hildesheim, R. (1988) · Physiological Reviews · doi:10.1152/physrev.1988.68.4.1285 · Cited by 543
Ursell, P. C., Gardner, P. I., Albala, A., Fenoglio, J. J., & Wit, A. L. (1985) · Circulation Research · doi:10.1161/01.res.56.3.436 · Cited by 441
Ross, W. N., Salzberg, B. M., Cohen, L. B., Grinvald, A., Davila, H. V., Waggoner, A. S., & Wang, C. H. (1977) · The Journal of Membrane Biology · doi:10.1007/bf01869514 · Cited by 345
Self-citationImproved fluorescent probes for the measurement of rapid changes in membrane potential
Grinvald, A., Hildesheim, R., Farber, I. C., & Anglister, L. (1982) · Biophysical Journal · doi:10.1016/s0006-3495(82)84520-7 · Cited by 258
Rohr, S., Schölly, D. M., & Kléber, A. G. (1991) · Circulation Research · doi:10.1161/01.res.68.1.114 · Cited by 217
Self-citationKamino, K. (1991) · Physiological Reviews · doi:10.1152/physrev.1991.71.1.53 · Cited by 214
Rudy, Y., & Quan, W. L. (1987) · Circulation Research · doi:10.1161/01.res.61.6.815 · Cited by 202
Sodium channels in cultured cardiac cells.
Cachelin, A. B., De Peyer, J. E., Kokubun, S., & Reuter, H. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014768 · Cited by 173
Cited by
Basic Mechanisms of Cardiac Impulse Propagation and Associated Arrhythmias
KLÉBER, A. G., & RUDY, Y. (2004) · Physiological Reviews · doi:10.1152/physrev.00025.2003 · Cited by 1,083
Microengineering of Cellular Interactions
Folch, A., & Toner, M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.227 · Cited by 602
Coupling of Cardiac Electrical Activity Over Extended Distances by Fibroblasts of Cardiac Origin
Gaudesius, G., Miragoli, M., Thomas, S. P., & Rohr, S. (2003) · Circulation Research · doi:10.1161/01.res.0000089258.40661.0c · Cited by 505
Self-citationRole of gap junctions in the propagation of the cardiac action potential
Rohr, S. (2004) · Cardiovascular Research · doi:10.1016/j.cardiores.2003.11.035 · Cited by 465
Self-citationEfimov, I. R., Nikolski, V. P., & Salama, G. (2004) · Circulation Research · doi:10.1161/01.res.0000130529.18016.35 · Cited by 390
Cardiac muscle tissue engineering: toward an in vitro model for electrophysiological studies
Bursac, N., Papadaki, M., Cohen, R. J., Schoen, F. J., Eisenberg, S. R., Carrier, R., Vunjak-Novakovic, G., & Freed, L. E. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.2.h433 · Cited by 366
Optical Imaging of Voltage and Calcium in Cardiac Cells & Tissues
Herron, T. J., Lee, P., & Jalife, J. (2012) · Circulation Research · doi:10.1161/circresaha.111.247494 · Cited by 289
Rohr, S., Kucera, J. P., & Kléber, A. G. (1998) · Circulation Research · doi:10.1161/01.res.83.8.781 · Cited by 271
Self-citationBiology on a Chip: Microfabrication for Studying the Behavior of Cultured Cells
Li, N., Tourovskaia, A., & Folch, A. (2003) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v31.i56.20 · Cited by 186
A hybrid approach to measuring electrical activity in genetically specified neurons
Chanda, B., Blunck, R., Faria, L. C., Schweizer, F. E., Mody, I., & Bezanilla, F. (2005) · Nature Neuroscience · doi:10.1038/nn1558 · Cited by 175
Visualizing Excitation Waves inside Cardiac Muscle Using Transillumination
Baxter, W. T., Mironov, S. F., Zaitsev, A. V., Jalife, J., & Pertsov, A. M. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76034-1 · Cited by 169
“Various technologies have been used to simultaneously record from multiple sites, including arrays of photodiodes (Rohr and Salzberg, 1994; Girouard et al., 1996), laser scanning (Dillon et al.”
MethodInfluentialOptical Recording of Action Potentials with Second-Harmonic Generation Microscopy
Dombeck, D. A., Blanchard-Desce, M., & Webb, W. W. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.4840-03.2004 · Cited by 166
“These fast probes can respond to a Vm change of 100 mV with up to 10 –20% changes in fluorescence emission (Grinvald et al., 1982; Loew et al., 1992; Rohr and Salzberg, 1994 ), although the response is typically limited to1% in practice (Zochowski et al., 2000).”
Background
Metadata
- Authors
- Rohr, S., & Salzberg, B. M.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1994-09
- Volume
- 67
- Issue
- 3
- Pages
- 1301-1315
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2072770548
- Cited by
- 161
- References
- 17
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.