The DOI matches its Crossref record.
Patterned growth of neonatal rat heart cells in culture. Morphological and electrophysiological characterization.
Abstract
A culture method was developed that permits patterning of the growth of ventricular myocytes of neonatal rats. Regions were created on the culture substrate that either prevented (photoresist coat) or supported (glass surface) attachment of cells. In this way the geometry of interconnecting growth channels could be specified. Single-layered myocyte strands of variable length and with widths of as little as 65 micron (three to four cells wide) were obtained. The shape and orientation of the individual myocytes were a function of growth-channel width: the narrower the channel, the more elongated the cells and the more likely was the long axis to be oriented along the channel axis. In channels with width of 100 micron or less, cells were aligned longitudinally and cross-striated as in vivo. A high degree of morphological cell differentiation required the presence of contractile activity. Maximal diastolic potential (-71 mV), action potential amplitude (93 mV), and maximal upstroke velocity (140 V/sec) did not change with increasing culture age. Mean longitudinal conduction velocity was 0.39 m/sec. No electrophysiological or morphological evidence of photoresist toxicity was seen, and the data indicate a high degree of cell differentiation in the patterned cell cultures. The method thus is suitable for the study of the relation between impulse propagation and structure at a cellular level in artificial networks of predefined shape.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Microengineering of Cellular Interactions
Folch, A., & Toner, M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.227 · Cited by 602
Controlling cell interactions by micropatterning in co-cultures: Hepatocytes and 3T3 fibroblasts
Bhatia, S. N., Yarmush, M. L., & Toner, M. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199702)34:2<189::aid-jbm8>3.0.co;2-m · Cited by 547
Ensembles of engineered cardiac tissues for physiological and pharmacological study: Heart on a chip
Grosberg, A., Alford, P. W., McCain, M. L., & Parker, K. K. (2011) · Lab on a Chip · doi:10.1039/c1lc20557a · Cited by 544
Role of gap junctions in the propagation of the cardiac action potential
Rohr, S. (2004) · Cardiovascular Research · doi:10.1016/j.cardiores.2003.11.035 · Cited by 465
Self-citation
Metadata
- Authors
- Rohr, S., Schölly, D. M., & Kléber, A. G.
- Venue
- Circulation Research
- Published
- 1991-01
- Volume
- 68
- Issue
- 1
- Pages
- 114-130
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2012933077
- Cited by
- 217
- References
- 0
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patterned growth of neonatal rat heart cells in culture. Morphological and electrophysiological characterization. https://app.cochat.ai/papers/10.1161/01.res.68.1.114
- The paper
- Rohr, S., Schölly, D. M., & Kléber, A. G. (1991). Patterned growth of neonatal rat heart cells in culture. Morphological and electrophysiological characterization. Circulation Research. https://doi.org/10.1161/01.res.68.1.114
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.