Electron Tomography of Ice-Embedded Prokaryotic Cells
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cryo-electron microscopy of vitrified specimens
Dubochet, J., Adrian, M., Chang, J.-J., Homo, J.-C., Lepault, J., McDowall, A. W., & Schultz, P. (1988) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004297 · Cited by 2,389 · cited 1×
“Sulfolobuscells (Brock et al., 1972; Schleper et al., 1995) were taken directly from stock solutions at an OD between 0.3 and 0.7, applied to a holey carbon grid, and plunge-frozen in liquid ethane (Dubochet et al., 1988).”
MethodInfluentialZimmerman, S. B., & Trach, S. O. (1991) · Journal of Molecular Biology · doi:10.1016/0022-2836(91)90499-v · Cited by 1,337 · cited 2×
“The obtained concentration is similar to the concentration measured by biochemical means forEscherichia coli cells, 0.3–0.4 g ml21 (Zimmerman and Trach, 1991).”
ResultInfluentialSulfolobus: A new genus of sulfur-oxidizing bacteria living at low pH and high temperature
Brock, T. D., Brock, K. M., Belly, R. T., & Weiss, R. L. (1972) · Archiv f�r Mikrobiologie · doi:10.1007/bf00408082 · Cited by 1,262
Crowther, R. A., DeRosier, D. J., & Klug, A. (1970) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1970.0119 · Cited by 972 · cited 1×
“Number of tilts and tilt scheme According to Crowther et al. (1970) and Hoppe (1969), the resolution of a reconstruction,d, is determined by the tilt incrementa0, assuming equidistant sampling of the angular range: d 5 Da0 (1) whereD is the diameter of the specimen, anda0 is given in radians.”
BackgroundSoft X-ray microscopes and their biological applications
Kirz, J., Jacobsen, C., & Howells, M. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500003139 · Cited by 672 · cited 1×
“With a current 3D resolution of ;100 nm on beam-insensitive specimens, one may eventually be able to reach 30–50 nm for biological specimens (Kirz et al., 1995; Sayre and Chapman, 1995).”
BackgroundMicrotubule nucleation by γ-tubulin-containing rings in the centrosome
Moritz, M., Braunfeld, M. B., Sedat, J. W., Alberts, B., & Agard, D. A. (1995) · Nature · doi:10.1038/378638a0 · Cited by 525 · cited 2×
“It has recently been applied to the study of stained sections of mitochondria (Mannella et al., 1994; Perkins et al., 1997), centrosomes (Moritz et al., 1995), and secretion organelles (Shillito et al., 1997).”
BackgroundPerkins, G., Renken, C., Martone, M. E., Young, S. J., Ellisman, M., & Frey, T. (1997) · Journal of Structural Biology · doi:10.1006/jsbi.1997.3885 · Cited by 395 · cited 1×
“It has recently been applied to the study of stained sections of mitochondria (Mannella et al., 1994; Perkins et al., 1997), centrosomes (Moritz et al., 1995), and secretion organelles (Shillito et al., 1997).”
BackgroundPyrobaculum aerophilum sp. nov., a novel nitrate-reducing hyperthermophilic archaeum
V�lkl, P., Huber, R., Drobner, E., Rachel, R., Burggraf, S., Trincone, A., & Stetter, K. O. (1993) · Applied and Environmental Microbiology · doi:10.1128/aem.59.9.2918-2926.1993 · Cited by 291 · cited 3×
“Cells ofPyrobaculum aerophilumwere first concentrated by centrifugation before application to the grid (Vo¨lkl et al., 1993).”
BackgroundMethodSelf-citationThree-dimensional reconstruction of imperfect two-dimensional crystals
Saxton, W. O., Baumeister, W., & Hahn, M. (1984) · Ultramicroscopy · doi:10.1016/0304-3991(84)90057-3 · Cited by 270 · cited 2×
“Even though different schemes for changing the tilt increment have been developed, the one by Saxton et al. (1984) has been most widely adapted.”
BackgroundSelf-citationTowards automatic electron tomography
Dierksen, K., Typke, D., Hegerl, R., Koster, A. J., & Baumeister, W. (1992) · Ultramicroscopy · doi:10.1016/0304-3991(92)90235-c · Cited by 216 · cited 1×
“To use most of the allowed dose for the actual image acquisition, tomographic procedures have to be highly automated (Koster et al., 1992; Dierksen et al., 1992, 1993; Braunfeld et al., 1994).”
MethodSelf-citationMannella, C. A., Marko, M., Penczek, P., Barnard, D., & Frank, J. (1994) · Microscopy Research and Technique · doi:10.1002/jemt.1070270403 · Cited by 184 · cited 2×
“It has recently been applied to the study of stained sections of mitochondria (Mannella et al., 1994; Perkins et al., 1997), centrosomes (Moritz et al.”
BackgroundThe EM Program Package: A Platform for Image Processing in Biological Electron Microscopy
Hegerl, R. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0006 · Cited by 162 · cited 2×
“projection with the EM software package (Hegerl, 1996), with an image”
MethodFar‐field fluorescence microscopy with three‐dimensional resolution in the 100‐nm range
Hell, S. W., Schrader, M., & van der Voort, H. T. M. (1997) · Journal of Microscopy · doi:10.1046/j.1365-2818.1997.2410797.x · Cited by 145 · cited 2×
“Although the resolution of conventional confocal microscopy is limited to ;200 nm in the x-y plane and 400 in the z direction, recently 4pconfocal microscopy has reached a resolution better than 100 nm in all directions (Hell et al., 1997).”
BackgroundSchleper, C., Holz, I., Janekovic, D., Murphy, J., & Zillig, W. (1995) · Journal of Bacteriology · doi:10.1128/jb.177.15.4417-4426.1995 · Cited by 134 · cited 1×
“Sulfolobuscells (Brock et al., 1972; Schleper et al., 1995) were taken directly from stock solutions at an OD between 0.3 and 0.7, applied to a holey carbon grid, and plunge-frozen in liquid ethane (Dubochet et al., 1988).”
MethodSelf-citationPrinciples of organization in eubacterial and archaebacterial surface proteins
Baumeister, W., Wildhaber, I., & Phipps, B. M. (1989) · Canadian Journal of Microbiology · doi:10.1139/m89-034 · Cited by 126 · cited 2×
“This space is thought to be functionally analogous to the periplasmic space of Gram-negative eubacteria and represents an extracellular compartment (Baumeister et al., 1989).”
BackgroundSelf-citationTowards automatic electron tomography II. Implementation of autofocus and low-dose procedures
Dierksen, K. P., Typke, D., Hegerl, R., & Baumeister, W. P. (1993) · Ultramicroscopy · doi:10.1016/0304-3991(93)90217-l · Cited by 123 · cited 1×
“To use most of the allowed dose for the actual image acquisition, tomographic procedures have to be highly automated (Koster et al., 1992; Dierksen et al., 1992, 1993; Braunfeld et al., 1994).”
MethodSelf-citationGrimm, R., Typke, D., Bärmann, M., & Baumeister, W. P. (1996) · Ultramicroscopy · doi:10.1016/0304-3991(96)00035-6 · Cited by 89 · cited 3×
“When ice-embedded specimens are investigated, the best contrast and resolution are generally achieved by selecting the zero-loss electrons for imaging (Grimm et al., 1996b).”
BackgroundMethodSelf-citationDierksen, K. P., Typke, D., Hegerl, R., Walz, J., Sackmann, E., & Baumeister, W. P. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80314-0 · Cited by 89 · cited 2×
“, 1993), lipid vesicles with or without cargo (Dierksen et al., 1995; Grimm et al., 1997), and macromolecules (Nitsch et al.”
BackgroundSelf-citationBraunfeld, M. B., Koster, A. J., Sedat, J. W., & Agard, D. A. (1994) · Journal of Microscopy · doi:10.1111/j.1365-2818.1994.tb03451.x · Cited by 73 · cited 1×
“To use most of the allowed dose for the actual image acquisition, tomographic procedures have to be highly automated (Koster et al., 1992; Dierksen et al., 1992, 1993; Braunfeld et al., 1994).”
MethodPhipps, B. M., Huber, R., & Baumeister, W. P. (1991) · Molecular Microbiology · doi:10.1111/j.1365-2958.1991.tb02106.x · Cited by 46 · cited 2×
“These stalks anchor the surface layer into the cell membrane, creating the (quasi-) periplasmic space (Phipps et al., 1990), which is 15–17 nm wide (Phipps et al., 1991).”
BackgroundSelf-citationShillito, B., Koster, A. J., Walz, J. C., & Baumeister, W. P. (1996) · Biology of the Cell · doi:10.1016/s0248-4900(97)86825-6 · Cited by 9 · cited 1×
“, 1995), and secretion organelles (Shillito et al., 1997).”
Self-citation
Cited by
Rosenthal, P. B., & Henderson, R. (2003) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.07.013 · Cited by 2,416
Macromolecular Architecture in Eukaryotic Cells Visualized by Cryoelectron Tomography
Medalia, O., Weber, I., Frangakis, A. S., Nicastro, D., Gerisch, G., & Baumeister, W. (2002) · Science · doi:10.1126/science.1076184 · Cited by 837
Self-citationSTRUCTURAL STUDIES BY ELECTRON TOMOGRAPHY: From Cells to Molecules
Lučić, V., Förster, F., & Baumeister, W. (2005) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.73.011303.074112 · Cited by 702
Self-citationLee, E., Choi, D., Kim, D., Kim, J., Park, J. O., Kim, S., Kim, S., Desiderio, D. M., Kim, Y., Kim, K., et al. (2009) · PROTEOMICS · doi:10.1002/pmic.200900338 · Cited by 669
Kim, D., Kang, B., Kim, O. Y., Choi, D., Lee, J., Kim, S. R., Go, G., Yoon, Y. J., Kim, J. H., Jang, S. C., et al. (2013) · Journal of Extracellular Vesicles · doi:10.3402/jev.v2i0.20384 · Cited by 569
Metadata
- Authors
- Grimm, R., Singh, H., Rachel, R., Typke, D., Zillig, W., & Baumeister, W.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1998-02
- Volume
- 74
- Issue
- 2
- Pages
- 1031-1042
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1969128629
- Cited by
- 209
- References
- 21
- FWCI
- 10.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.