Extending the Range of Rate Constants Available from BIACORE: Interpreting Mass Transport-Influenced Binding Data
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Surface-based binding assays are often influenced by the transport of analyte to the sensor surface. Using simulated data sets, we test a simple two-compartment model to see if its description of transport and binding is sufficient to accurately analyze BIACORE data. First we present a computer model that can generate realistic BIACORE data. This model calculates the laminar flow of analyte within the flow cell, its diffusion both perpendicular and parallel to the sensor surface, and the reversible chemical reaction between analyte and immobilized reactant. We use this computer model to generate binding data under a variety of conditions. An analysis of these data sets with the two-compartment model demonstrates that good estimates of the intrinsic reaction rate constants are recovered even when mass transport influences the binding reaction. We also discuss the conditions under which the two-compartment model can be used to determine the diffusion coefficient of the analyte. Our results illustrate that this model can significantly extend the range of association rate constants that can be accurately determined from BIACORE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Fluid Dynamics
Batchelor, G. K. (2000) · doi:10.1017/cbo9780511800955 · Cited by 12,360
An introduction to fluid dynamics
Curle, N. (1968) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(68)90038-0 · Cited by 6,135
Stenberg, E., Persson, B., Roos, H., & Urbaniczky, C. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90284-f · Cited by 1,059
Jönsson, U., Fägerstam, L. G., Ivarsson, B., Johnsson, B., Karlsson, R., Lundh, K., Löfås, S., Persson, B. S., Roos, H., & Rönnberg, I. (1991) · PubMed · Cited by 902
The Quasi-Steady-State Assumption: A Case Study in Perturbation
Segel, L. A., & Slemrod, M. (1989) · SIAM Review · doi:10.1137/1031091 · Cited by 717
Schuck, P. (1997) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.26.1.541 · Cited by 657
Karlsson, R., & Fält, A. (1997) · Journal of Immunological Methods · doi:10.1016/s0022-1759(96)00195-0 · Cited by 568
Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors
Myszka, D. G. (1997) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(97)80157-7 · Cited by 552
Self-citationBiotechnology at low Reynolds numbers
Brody, J. P., Yager, P., Goldstein, R. E., & Austin, R. H. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79538-3 · Cited by 523
Glaser, R. W. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1399 · Cited by 361
Morton, T. A., Myszka, D. G., & Chaiken, I. M. (1995) · Analytical Biochemistry · doi:10.1006/abio.1995.1268 · Cited by 334
Self-citation[13] Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors
Morton, T. A., & Myszka, D. G. (1998) · Methods in Enzymology · doi:10.1016/s0076-6879(98)95044-3 · Cited by 308
Self-citationKinetic and Concentration Analysis Using BIA Technology
Karlsson, R., Roos, H., Fägerstam, L., & Persson, B. (1994) · Methods · doi:10.1006/meth.1994.1013 · Cited by 277
Integrated fluid handling system for biomolecular interaction analysis
Sjoelander, S., & Urbaniczky, C. (1991) · Analytical Chemistry · doi:10.1021/ac00020a025 · Cited by 270
Surface plasmon resonance and its use in biomolecular interaction analysis (BIA)
Szabo, A., Stolz, L., & Granzow, R. (1995) · Current Opinion in Structural Biology · doi:10.1016/0959-440x(95)80064-6 · Cited by 238
Schuck, P. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79681-9 · Cited by 233
Analysis of Mass Transport-Limited Binding Kinetics in Evanescent Wave Biosensors
Schuck, P., & Minton, A. P. (1996) · Analytical Biochemistry · doi:10.1006/abio.1996.0356 · Cited by 219
Surface plasmon resonance for detection and measurement of antibody-antigen affinity and kinetics
Malmqvist, M. (1993) · Current Opinion in Immunology · doi:10.1016/0952-7915(93)90019-o · Cited by 212
BIAcore for macromolecular interaction
Fivash, M., Towler, E. M., & Fisher, R. J. (1998) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(98)80091-8 · Cited by 205
Analysis of macromolecular interactions using immobilized ligands
Chaiken, I., Rosé, S., & Karlsson, R. (1992) · Analytical Biochemistry · doi:10.1016/0003-2697(92)90329-6 · Cited by 182
Reliable determination of binding affinity and kinetics using surface plasmon resonance biosensors
Schuck, P. (1997) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(97)80074-2 · Cited by 176
Optical evanescent wave methods for the study of biomolecular interactions
Garland, P. B. (1996) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500005758 · Cited by 137
Analysis of cell-adhesion molecule interactions using surface plasmon resonance
van der Merwe, P. A., & Barclay, A. N. (1996) · Current Opinion in Immunology · doi:10.1016/s0952-7915(96)80065-3 · Cited by 120
Straume, M., & Johnson, M. L. (1992) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(92)10009-3 · Cited by 105
Global Analysis of a Macromolecular Interaction Measured on BIAcore
Roden, L. D., & Myszka, D. G. (1996) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1996.1297 · Cited by 102
Self-citationReal Time Analysis of Antibody‐Antigen Reaction Kinetics
MALMBORG, A. ‐., MICHAËLSSON, A., OHLIN, M., JANSSON, B., & BORREBAECK, C. A. K. (1992) · Scandinavian Journal of Immunology · doi:10.1111/j.1365-3083.1992.tb02970.x · Cited by 99
Biotechnological applications of surface plasmon resonance
Silin, V. I., & Plant, A. L. (1997) · Trends in biotechnology · doi:10.1016/s0167-7799(97)01085-8 · Cited by 95
Myszka, D. G., Arulanantham, P. R., Sana, T. R., Wu, Z., Morton, T. A., & Ciardelli, T. L. (1996) · Protein Science · doi:10.1002/pro.5560051209 · Cited by 90
Self-citationYarmush, M. L., Patankar, D. B., & Yarmush, D. M. (1996) · Molecular Immunology · doi:10.1016/s0161-5890(96)00075-2 · Cited by 75
Cited by
Making it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
Krishnamurthy, V. M., Kaufman, G. K., Urbach, A. R., Gitlin, I., Gudiksen, K. L., Weibel, D. B., & Whitesides, G. M. (2008) · Chemical Reviews · doi:10.1021/cr050262p · Cited by 761
Advances in surface plasmon resonance biosensor analysis
Rich, R. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00054-3 · Cited by 665
Detection Limits for Nanoscale Biosensors
Sheehan, P. E., & Whitman, L. J. (2005) · Nano Letters · doi:10.1021/nl050298x · Cited by 615
Kaufman, B. A., Durisic, N., Mativetsky, J. M., Costantino, S., Hancock, M. A., Grutter, P., & Shoubridge, E. A. (2007) · Molecular Biology of the Cell · doi:10.1091/mbc.e07-05-0404 · Cited by 427
Metadata
- Authors
- Myszka, D. G., He, X., Dembo, M., Morton, T. A., & Goldstein, B.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1998-08
- Volume
- 75
- Issue
- 2
- Pages
- 583-594
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2161572382
- Cited by
- 415
- References
- 29
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.