Video-Rate Scanning Two-Photon Excitation Fluorescence Microscopy and Ratio Imaging with Cameleons
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
A video-rate (30 frames/s) scanning two-photon excitation microscope has been successfully tested. The microscope, based on a Nikon RCM 8000, incorporates a femtosecond pulsed laser with wavelength tunable from 690 to 1050 nm, prechirper optics for laser pulse-width compression, resonant galvanometer for video-rate point scanning, and a pair of nonconfocal detectors for fast emission ratioing. An increase in fluorescent emission of 1.75-fold is consistently obtained with the use of the prechirper optics. The nonconfocal detectors provide another 2.25-fold increase in detection efficiency. Ratio imaging and optical sectioning can therefore be performed more efficiently without confocal optics. Faster frame rates, at 60, 120, and 240 frames/s, can be achieved with proportionally reduced scan lines per frame. Useful two-photon images can be acquired at video rate with a laser power as low as 2.7 mW at specimen with the genetically modified green fluorescent proteins. Preliminary results obtained using this system confirm that the yellow "cameleons" exhibit similar optical properties as under one-photon excitation conditions. Dynamic two-photon images of cardiac myocytes and ratio images of yellow cameleon-2.1, -3.1, and -3.1nu are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488 · cited 1×
“Two-photon excitation microscopy (TPEM) Denk et al., 1990) represents one of the most significant advances in light microscopy since the introduction of laser-scanning confocal microscopy (Carlsson et al., 1985; Åslund et al., 1998; White et al., 1987; Amos et al., 1987).”
BackgroundHandbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Fluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,248 · cited 5×
“A new class of protein-based Ca(2) indicators dubbed “cameleons” has major advantages over previous smallmolecule indicators in that the cameleons are entirely genetically encoded and targetable to specific tissues and intracellular locations (Miyawaki et al., 1997).”
BackgroundSelf-citationXu, C., & Webb, W. W. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000481 · Cited by 2,198 · cited 2×
“Many existing fluorophores have been tested for TPEM, including the commonly used dyes such as fluorescein and rhodamine, Ca21 indicators such as indo-1, and early versions of green fluorescent protein (GFP) (Xu and Webb, 1996; Xu et al., 1996).”
BackgroundMethodHandbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Fluorescent indicators for cytosolic calcium based on rhodamine and fluorescein chromophores
Minta, A., Kao, J. P. Y., & Tsien, R. Y. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)83165-9 · Cited by 1,613 · cited 2×
“The use of the IR-cut filter in our system makes it safe to observe the fluorescent images through the microscope binocular eyepieces while the laser is scanning the specimen.”
MethodSelf-citationMultiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy.
Xu, C., Zipfel, W., Shear, J. B., Williams, R. M., & Webb, W. W. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.20.10763 · Cited by 1,165 · cited 14×
“Scale bar, 10mm. Colonies ofEscherichia coliJM109 (DE 3) strain transformed with EGFPgene in pRSETB (Invitrogen, San Diego, CA) were grown at room temperature and then suspended in 20 mM HEPES, pH 7.2, 100 mM KCl. HeLa cells were imaged at room temperature in HBSS 2–5 days after transfection with yellow cameleon-2.”
MethodInfluentialNegative dispersion using pairs of prisms
Fork, R. L., Martinez, O. E., & Gordon, J. P. (1984) · Optics Letters · doi:10.1364/ol.9.000150 · Cited by 944 · cited 3×
“We have thus moved the detectors (PMTs) from the confocal port to the side port of the microscope, as illustrated in Fig.”
BackgroundMethodInfluentialWhite, J. G., Amos, W. B., & Fordham, M. (1987) · The Journal of cell biology · doi:10.1083/jcb.105.1.41 · Cited by 858 · cited 1×
“Two-photon excitation microscopy (TPEM) Denk et al., 1990) represents one of the most significant advances in light microscopy since the introduction of laser-scanning confocal microscopy (Carlsson et al., 1985; Åslund et al., 1998; White et al., 1987; Amos et al., 1987).”
BackgroundPhoton Upmanship: Why Multiphoton Imaging Is More than a Gimmick
Denk, W., & Svoboda, K. (1997) · Neuron · doi:10.1016/s0896-6273(00)81237-4 · Cited by 676
Multifocal multiphoton microscopy
Bewersdorf, J., Pick, R., & Hell, S. W. (1998) · Optics Letters · doi:10.1364/ol.23.000655 · Cited by 429 · cited 3×
“, 1996) and rotating microlens array (Bewersdorf et al., 1998) are used to achieve scan rates faster than video rate. In both implementations, an image is formed on a 2D detector. Therefore, image quality relies on the spatial registration of the fluorescent photons, which, as pointed out by Denk and Svoboda (1997), s…”
MethodThe nucleus is insulated from large cytosolic calcium ion changes
Al-Mohanna, F. A., Caddy, K. W. T., & Bolsover, S. R. (1994) · Nature · doi:10.1038/367745a0 · Cited by 250 · cited 2×
“Comparative measurements of nuclear and cytosolic Ca concentration have been performed using synthetic fluorescent chelators (Al-Mohanna et al., 1994; Brown et al., 1997; Malviya and Rogue, 1998).”
MethodNuclear Ca2+ concentration measured with specifically targeted recombinant aequorin.
Brini, M., Murgia, M., Pasti, L., Picard, D., Pozzan, T., & Rizzuto, R. (1993) · The EMBO Journal · doi:10.1002/j.1460-2075.1993.tb06170.x · Cited by 202 · cited 1×
“The Ca21-sensitive photoprotein aequorin has been localized specifically in nucleus and cytosol (Brini et al., 1994, 1998; Badminton et al., 1996, 1998), but it has not been possible to image nuclear and cytosolic aequorin signals simultaneously in the same individual cells.”
BackgroundA theoretical analysis of the two-photon properties of linear polyenes and the visual chromophores
Birge, R. R., & Pierce, B. M. (1979) · The Journal of Chemical Physics · doi:10.1063/1.437217 · Cited by 159
Use of confocal imaging in the study of biological structures
Amos, W. B., White, J. G., & Fordham, M. (1987) · Applied Optics · doi:10.1364/ao.26.003239 · Cited by 140 · cited 1×
“Two-photon excitation microscopy (TPEM) Denk et al., 1990) represents one of the most significant advances in light microscopy since the introduction of laser-scanning confocal microscopy (Carlsson et al., 1985; Åslund et al., 1998; White et al., 1987; Amos et al., 1987).”
BackgroundReal‐time two‐photon confocal microscopy using a femtosecond, amplified Ti:sapphire system
Brakenhoff, G. J., Squier, J. A., Norris, T. B., Bliton, A. C., Wade, M., & Athey, B. D. (1996) · Journal of Microscopy · doi:10.1046/j.1365-2818.1996.97379.x · Cited by 127 · cited 1×
“Systems with faster scan rate have also been reported recently, in which line excitation (Brakenhoff et al., 1996) and rotating microlens array (Bewersdorf et al., 1998) are used to achieve scan rates faster than video rate.”
Method“Tell Me Where Is Calcium Bred”: Clarifying the Roles of Nuclear Calcium
Malviya, A. N., & Rogue, P. J. (1998) · Cell · doi:10.1016/s0092-8674(00)80895-8 · Cited by 124
Guild, J. B., Xu, C., & Webb, W. W. (1997) · Applied Optics · doi:10.1364/ao.36.000397 · Cited by 116 · cited 1×
“The dispersion properties of some microscope objective lenses have been determined and have been shown to cause substantial pulse widening if left uncompensated (Guild et al., 1997).”
BackgroundDifferential Regulation of Nuclear and Cytosolic Ca2+ in HeLa Cells
Badminton, M. N., Campbell, A. K., & Rembold, C. M. (1996) · Journal of Biological Chemistry · doi:10.1074/jbc.271.49.31210 · Cited by 106
Curley, P. F., Ferguson, A. I., White, J. G., & Amos, W. B. (1992) · Optical and Quantum Electronics · doi:10.1007/bf00620198 · Cited by 92 · cited 1×
“However, almost all fluorophores show the same emission spectra with either mode of excitation (Curley et al., 1992; Xu and Webb, 1996).”
BackgroundBrini, M., Marsault, R., Bastianutto, C., Pozzan, T., & Rizzuto, R. (1994) · Cell Calcium · doi:10.1016/0143-4160(94)90089-2 · Cited by 81 · cited 1×
“The Ca21-sensitive photoprotein aequorin has been localized specifically in nucleus and cytosol (Brini et al., 1994, 1998; Badminton et al., 1996, 1998), but it has not been possible to image nuclear and cytosolic aequorin signals simultaneously in the same individual cells.”
BackgroundParallel changes in nuclear and cytosolic calcium in mouse pancreatic β-cells
BROWN, G. R., Köhler, M. G., & Berggren, P. (1997) · Biochemical Journal · doi:10.1042/bj3250771 · Cited by 26 · cited 2×
“Comparative measurements of nuclear and cytosolic Ca(2) concentration have been performed using synthetic fluorescent chelators (Al-Mohanna et al., 1994; Brown et al., 1997; Malviya and Rogue, 1998).”
MethodFemtosecond pulse width control in microscopy by two‐photon absorption autocorrelation
Brakenhoff, G. J., Mueller, M., & Squier, J. A. (1995) · Journal of Microscopy · doi:10.1111/j.1365-2818.1995.tb03638.x · Cited by 25 · cited 1×
“A similar implementation has also been reported by Brakenhoff et al. (1995).”
ResultInsulin-like immunoreactivity in human cerebrospinal-fluid is independent of insulin blood levels.
Reiser, M., Lenz, E., Hg, B., & Dorn, A. (1985) · PubMed · Cited by 18
Imaging of Cellular Dynamics by Two-Photon Excitation Microscopy
Piston, D. W., Bennett, B. D., & Ying, G. (1995) · Microscopy and Microanalysis · doi:10.1017/s1431927695110259 · Cited by 8
Cited by
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
A high signal-to-noise Ca2+ probe composed of a single green fluorescent protein
Nakai, J., Ohkura, M., & Imoto, K. (2001) · Nature Biotechnology · doi:10.1038/84397 · Cited by 1,616
Grienberger, C., & Konnerth, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.02.011 · Cited by 1,354
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
“New developments focus on fast resonator scanners (Fan et al., 1999).”
Background
Metadata
- Authors
- Fan, G. Y., Fujisaki, H., Miyawaki, A., Tsay, R.-K., Tsien, R. Y., & Ellisman, M. H.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1999-05
- Volume
- 76
- Issue
- 5
- Pages
- 2412-2420
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1997192016
- Cited by
- 231
- References
- 25
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.