Video-Rate Scanning Two-Photon Excitation Fluorescence Microscopy and Ratio Imaging with Cameleons
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
A video-rate (30 frames/s) scanning two-photon excitation microscope has been successfully tested. The microscope, based on a Nikon RCM 8000, incorporates a femtosecond pulsed laser with wavelength tunable from 690 to 1050 nm, prechirper optics for laser pulse-width compression, resonant galvanometer for video-rate point scanning, and a pair of nonconfocal detectors for fast emission ratioing. An increase in fluorescent emission of 1.75-fold is consistently obtained with the use of the prechirper optics. The nonconfocal detectors provide another 2.25-fold increase in detection efficiency. Ratio imaging and optical sectioning can therefore be performed more efficiently without confocal optics. Faster frame rates, at 60, 120, and 240 frames/s, can be achieved with proportionally reduced scan lines per frame. Useful two-photon images can be acquired at video rate with a laser power as low as 2.7 mW at specimen with the genetically modified green fluorescent proteins. Preliminary results obtained using this system confirm that the yellow "cameleons" exhibit similar optical properties as under one-photon excitation conditions. Dynamic two-photon images of cardiac myocytes and ratio images of yellow cameleon-2.1, -3.1, and -3.1nu are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488 · cited 1×
“Two-photon excitation microscopy (TPEM) Denk et al., 1990) represents one of the most significant advances in light microscopy since the introduction of laser-scanning confocal microscopy (Carlsson et al., 1985; Åslund et al., 1998; White et al., 1987; Amos et al., 1987).”
BackgroundHandbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Fluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,248 · cited 5×
“A new class of protein-based Ca(2) indicators dubbed “cameleons” has major advantages over previous smallmolecule indicators in that the cameleons are entirely genetically encoded and targetable to specific tissues and intracellular locations (Miyawaki et al., 1997).”
BackgroundSelf-citationXu, C., & Webb, W. W. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000481 · Cited by 2,198 · cited 2×
“Many existing fluorophores have been tested for TPEM, including the commonly used dyes such as fluorescein and rhodamine, Ca21 indicators such as indo-1, and early versions of green fluorescent protein (GFP) (Xu and Webb, 1996; Xu et al., 1996).”
BackgroundMethodHandbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Fluorescent indicators for cytosolic calcium based on rhodamine and fluorescein chromophores
Minta, A., Kao, J. P. Y., & Tsien, R. Y. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)83165-9 · Cited by 1,613 · cited 2×
“The use of the IR-cut filter in our system makes it safe to observe the fluorescent images through the microscope binocular eyepieces while the laser is scanning the specimen.”
MethodSelf-citationMultiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy.
Xu, C., Zipfel, W., Shear, J. B., Williams, R. M., & Webb, W. W. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.20.10763 · Cited by 1,165 · cited 14×
“Scale bar, 10mm. Colonies ofEscherichia coliJM109 (DE 3) strain transformed with EGFPgene in pRSETB (Invitrogen, San Diego, CA) were grown at room temperature and then suspended in 20 mM HEPES, pH 7.2, 100 mM KCl. HeLa cells were imaged at room temperature in HBSS 2–5 days after transfection with yellow cameleon-2.”
MethodInfluentialNegative dispersion using pairs of prisms
Fork, R. L., Martinez, O. E., & Gordon, J. P. (1984) · Optics Letters · doi:10.1364/ol.9.000150 · Cited by 944 · cited 3×
“We have thus moved the detectors (PMTs) from the confocal port to the side port of the microscope, as illustrated in Fig.”
BackgroundMethodInfluentialWhite, J. G., Amos, W. B., & Fordham, M. (1987) · The Journal of cell biology · doi:10.1083/jcb.105.1.41 · Cited by 858 · cited 1×
“Two-photon excitation microscopy (TPEM) Denk et al., 1990) represents one of the most significant advances in light microscopy since the introduction of laser-scanning confocal microscopy (Carlsson et al., 1985; Åslund et al., 1998; White et al., 1987; Amos et al., 1987).”
BackgroundPhoton Upmanship: Why Multiphoton Imaging Is More than a Gimmick
Denk, W., & Svoboda, K. (1997) · Neuron · doi:10.1016/s0896-6273(00)81237-4 · Cited by 676
Cited by
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
A high signal-to-noise Ca2+ probe composed of a single green fluorescent protein
Nakai, J., Ohkura, M., & Imoto, K. (2001) · Nature Biotechnology · doi:10.1038/84397 · Cited by 1,616
Grienberger, C., & Konnerth, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.02.011 · Cited by 1,354
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
“New developments focus on fast resonator scanners (Fan et al., 1999).”
BackgroundTwo-Photon Excitation Fluorescence Microscopy
So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.399 · Cited by 1,057
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Circularly permuted green fluorescent proteins engineered to sense Ca 2+
Nagai, T., Sawano, A., Park, E. S., & Miyawaki, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.051636098 · Cited by 966
Self-citationDynamic and quantitative Ca 2+ measurements using improved cameleons
Miyawaki, A., Griesbeck, O., Heim, R., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.5.2135 · Cited by 823
Self-citationA large field of view two-photon mesoscope with subcellular resolution for in vivo imaging
Sofroniew, N. J., Flickinger, D., King, J., & Svoboda, K. (2016) · eLife · doi:10.7554/elife.14472 · Cited by 645
Advances in multiphoton microscopy technology
Hoover, E. E., & Squier, J. A. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.361 · Cited by 542
FUKUMURA, D., DUDA, D. G., MUNN, L. L., & JAIN, R. K. (2010) · Microcirculation · doi:10.1111/j.1549-8719.2010.00029.x · Cited by 451
Activity of Rho-family GTPases during cell division as visualized with FRET-based probes
Yoshizaki, H., Ohba, Y., Kurokawa, K., Itoh, R. E., Nakamura, T., Mochizuki, N., Nagashima, K., & Matsuda, M. (2003) · The Journal of Cell Biology · doi:10.1083/jcb.200212049 · Cited by 412
Optical Imaging of Calcium Transients in Neurons and Pharyngeal Muscle of C. elegans
Kerr, R., Lev-Ram, V., Baird, G., Vincent, P., Tsien, R. Y., & Schafer, W. R. (2000) · Neuron · doi:10.1016/s0896-6273(00)81196-4 · Cited by 405
Self-citationMultiphoton microscopy in biological research
Williams, R. M., Zipfel, W. R., & Webb, W. W. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00241-6 · Cited by 370
Cardiac Energy Metabolism Homeostasis: Role of Cytosolic Calcium
Balaban, R. S. (2002) · Journal of Molecular and Cellular Cardiology · doi:10.1006/jmcc.2002.2082 · Cited by 357
A Cellular Resolution Map of Barrel Cortex Activity during Tactile Behavior
Peron, S. P., Freeman, J., Iyer, V., Guo, C., & Svoboda, K. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.027 · Cited by 346
Imaging in vivo: watching the brain in action
Kerr, J. N. D., & Denk, W. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2338 · Cited by 346
SLM microscopy: scanless two-photon imaging and photostimulation using spatial light modulators
Nikolenko, V. (2008) · Frontiers in Neural Circuits · doi:10.3389/neuro.04.005.2008 · Cited by 340
Two-Photon Microscopy of Cells and Tissue
Rubart, M. (2004) · Circulation Research · doi:10.1161/01.res.0000150593.30324.42 · Cited by 339
Two-photon fluorescence excitation and related techniques in biological microscopy
Diaspro, A., Chirico, G., & Collini, M. (2005) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583505004129 · Cited by 318
Functional studies of the kidney of living animals using multicolor two-photon microscopy
Dunn, K. W., Sandoval, R. M., Kelly, K. J., Dagher, P. C., Tanner, G. A., Atkinson, S. J., Bacallao, R. L., & Molitoris, B. A. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00159.2002 · Cited by 311
Simultaneous two-photon calcium imaging at different depths with spatiotemporal multiplexing
Cheng, A., Gonçalves, J. T., Golshani, P., Arisaka, K., & Portera-Cailliau, C. (2011) · Nature Methods · doi:10.1038/nmeth.1552 · Cited by 289
Technologies for imaging neural activity in large volumes
Ji, N., Freeman, J., & Smith, S. L. (2016) · Nature Neuroscience · doi:10.1038/nn.4358 · Cited by 278
Dynamic imaging of the immune system: progress, pitfalls and promise
Germain, R. N., Miller, M. J., Dustin, M. L., & Nussenzweig, M. C. (2006) · Nature Reviews Immunology · doi:10.1038/nri1884 · Cited by 274
Arnaudeau, S., Kelley, W. L., Walsh, J. V., & Demaurex, N. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m103274200 · Cited by 269
Wiseman, P. W., Brown, C. M., Webb, D. J., Hebert, B., Johnson, N. L., Squier, J. A., Ellisman, M. H., & Horwitz, A. F. (2004) · Journal of Cell Science · doi:10.1242/jcs.01416 · Cited by 232
“Aspects of the microscope scan optics and electronics have been described in more detail previously for a prototype microscope of similar configuration (Fan et al., 1999).”
Self-citationA global view of protein expression in human cells, tissues, and organs
Pontén, F., Gry, M., Fagerberg, L., Lundberg, E., Asplund, A., Berglund, L., Oksvold, P., Björling, E., Hober, S., Kampf, C., et al. (2009) · Molecular Systems Biology · doi:10.1038/msb.2009.93 · Cited by 222
Calcium signalling during embryonic development
Webb, S. E., & Miller, A. L. (2003) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1149 · Cited by 221
“In particular, Roger Tsien and co-workers have contributed immensely to this field of research by developing various innovative tools and technique”
BackgroundSpike Inference from Calcium Imaging Using Sequential Monte Carlo Methods
Vogelstein, J. T., Watson, B. O., Packer, A. M., Yuste, R., Jedynak, B., & Paninski, L. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2008.08.005 · Cited by 220
“PSq Ft Ca2þ t 1⁄4 def NðFt; m2P; s(2)2PÞ if t=d ̨Z 1 otherwise; (37)”
Kurokawa, K., Itoh, R. E., Yoshizaki, H., Nakamura, Y. O. T., & Matsuda, M. (2004) · Molecular Biology of the Cell · doi:10.1091/mbc.e03-08-0609 · Cited by 203
“Abbreviations used: CFP, cyan fluorescent protein; EGF, epidermal growth factor; FRET, fluorescent resonance energy transfer; GAP, GTPase-activating protein; GDI, guanine nucleotide dissociation inhibitor; GEF, guanine nucleotide exchange factor; GFP, green fluorescent protein; mRFP, monomeric red fluorescent protein;…”
MethodInfluentialTwo‐photon image correlation spectroscopy and image cross‐correlation spectroscopy
Wiseman, P. W., Squier, J. A., Ellisman, M. H., & Wilson, K. R. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00736.x · Cited by 175
“Aspects of the microscope, scan optics, and electronics have been described in more detail previously (Fan et al., 1999).”
Self-citationCarriles, R., Schafer, D. N., Sheetz, K. E., Field, J. J., Cisek, R., Barzda, V., Sylvester, A. W., & Squier, J. A. (2009) · Review of Scientific Instruments · doi:10.1063/1.3184828 · Cited by 170
Imaging angiogenesis and the microenvironment
FUKUMURA, D., & JAIN, R. K. (2008) · APMIS · doi:10.1111/j.1600-0463.2008.01148.x · Cited by 162
Lehmann, F.-O., Skandalis, D. A., & Berthé, R. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.1050 · Cited by 28
“1) in Drosophila melanogaster [50–53].”
Metadata
- Authors
- Fan, G. Y., Fujisaki, H., Miyawaki, A., Tsay, R.-K., Tsien, R. Y., & Ellisman, M. H.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1999-05
- Volume
- 76
- Issue
- 5
- Pages
- 2412-2420
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1997192016
- Cited by
- 231
- References
- 25
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.