Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

High resolution optical mapping reveals conduction slowing in connexin43 deficient mice

Eloff, B · 2001 · Cardiovascular Research

Abstract

UNLABELLED: Analysis of mice with genetically altered expression of cardiac connexins can provide insights into the role of individual gap junction channel proteins in cell-to-cell communication, impulse propagation, and arrhythmias. However, conflicting results have been reported regarding conduction velocity slowing in mice heterozygous for a null mutation in the gene encoding connexin43 (Cx43). METHODS: High-resolution optical mapping was used to record action potentials from 256 sites, simultaneously, on the ventricular surface of Langendorff perfused hearts from 15 heterozygous (Cx43+/-) and 8 wildtype (Cx43+/+) mice (controls). A sensitive method for measuring epicardial conduction velocity was developed to minimize confounding influences of subepicardial breakthrough and virtual electrode effects. RESULTS: Epicardial conduction velocity was significantly slower (23 to 35%, P<0.01) in Cx43+/- mice compared to wildtype. There was no change in conduction patterns or anisotropic ratio (Cx43+/- 1.54+/-0.33; Cx43+/+ 1.57+/-0.17) suggesting that Cx43 expression was reduced uniformly throughout myocardium. The magnitude of reductions in conduction velocity and Cx43 protein expression (45%) were similar in mice in which the null allele occurred in a pure C57BL/6J genetic background versus a mixed (C57BL/6J X 129) background. Action potential duration did not differ between mice of different genotypes. CONCLUSIONS: A approximately 50% reduction of Cx43 expression causes significant conduction velocity slowing in the Cx43+/- mouse heart. The apparent lack of conduction velocity changes reported in previous studies may be related to technical factors rather than variations in genetic background. High-resolution optical mapping is a powerful tool for investigating molecular determinants of propagation and arrhythmias in genetically engineered mice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0008-6363(01)00341-8

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Eloff, B.
Venue
Cardiovascular Research
Published
2001-09
Volume
51
Issue
4
Pages
681-690
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2031070609
Cited by
161
References
2
FWCI
8.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High resolution optical mapping reveals conduction slowing in connexin43 deficient mice. https://app.cochat.ai/papers/10.1016/s0008-6363(01)00341-8
The paper
Eloff, B. (2001). High resolution optical mapping reveals conduction slowing in connexin43 deficient mice. Cardiovascular Research. https://doi.org/10.1016/s0008-6363(01)00341-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.