CoChat

Electrophysiological features of the mouse sinoatrial node in relation to connexin distribution

Open access
Verheijck, E · 2001 · Cardiovascular Research
Cited by 172

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The sinoatrial (SA) node consists of a relatively small number of poorly coupled cells. It is not well understood how these pacemaker cells drive the surrounding atrium and at the same time are protected from its hyperpolarizing influence. To explore this issue on a small tissue scale we studied the activation pattern of the mouse SA node region and correlated this pattern with the distribution of different gap junction proteins, connexin (Cx)37, Cx40, Cx43 and Cx45. METHODS AND RESULTS: The mouse SA node was electrophysiologically mapped using a conventional microelectrode technique. The primary pacemaker area was located in the corner between the lateral and medial limb of the crista terminalis. Unifocal pacemaking occurred in a group of pacemaking fibers consisting of 450 cells. In the nodal area transitions of nodal and atrial waveform were observed over small distances ( approximately 100 microm). Correlation between the activation pattern and connexin distribution revealed extensive labeling by anti-Cx45 in the primary and secondary pacemaker area. Within these nodal areas no gradient in Cx45 labeling was found. A sharp transition was found between Cx40- and Cx43-expressing myocytes of the crista terminalis and the Cx45-expressing myocytes of the node. In addition, strands of myocytes labeled for Cx43 and Cx40 protrude into the nodal area. Cx37 labeling was only present between endothelial cells. Furthermore, a band of connective tissue largely separates the nodal from the atrial tissue. CONCLUSIONS: Our results demonstrate strands of Cx43 and Cx40 positive atrial cells protruding into the Cx45 positive nodal area and a band of connective tissue largely separating the nodal and atrial tissue. This organization of the mouse SA node provides a structural substrate that both shields the nodal area from the hyperpolarizing influence of the atrium and allows fast action potential conduction from the nodal area into the surrounding atrium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0008-6363(01)00364-9

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

Metadata

Authors
Verheijck, E.
Venue
Cardiovascular Research
Published
2001-10
Volume
52
Issue
1
Pages
40-50
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2089792236
Cited by
172
References
26
FWCI
4.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.