Cited by 37Cardiac electrophysiology and arrhythmiasCardiac pacing and defibrillation studiesCardiac Arrhythmias and Treatments

Repolarization abnormalities and their arrhythmogenic consequences in porcine tachycardia-induced cardiomyopathy

Lacroix, D·2002·Cardiovascular Research

Abstract

OBJECTIVES: Action potential prolongation related to the alteration of several membrane currents is constantly reported in heart failure (HF) but reports about its role in arrhythmogenesis are sparse. Our aim was to determine, by analogy with long QT syndromes, whether prolonged repolarization is associated with increased dispersion or linked to bradycardia-dependent ventricular arrhythmias in pacing-induced cardiomyopathy. METHODS: QT intervals, action potentials and transmural activation-to-recovery intervals (ARIs) along with whole-cell delayed rectifier (I(K)) and transient outward (I(to1)) K+ currents were recorded in left ventricle from pigs with HF and controls. HF was obtained after 14 days of rapid pacing at 250 ms. RESULTS: Repolarization was delayed as indexed by corrected QT intervals (13.7% increase, P<0.01) or ARIs (252+/-4 to 340+/-7 ms, P<0.01). ARIs were uniformly prolonged with disappearance of the transmural gradient, spatial dispersion of repolarization decreased by 50% (P<0.05). I(to1) density was reduced in HF from 1.35+/-0.1 to 0.57+/-0.04 pA/pF subepicardially, from 1.05+/-0.19 to 0.55+/-0.08 pA/pF midmyocardially and from 1.04+/-0.1 to 0.48+/-0.04 pA/pF subendocardially. I(K) density was significantly decreased in HF pigs vs. controls: subepicardially from 0.46+/-0.04 to 0.22+/-0.02 pA/pF; midmyocardially from 0.46+/-0.05 to 0.25+/-0.03 pA/pF; and subendocardially from 0.49+/-0.04 to 0.20+/-0.04 pA/pF following depolarization at +50 mV. Electrocardiogram (ECG) monitoring at the time of death did not disclose any polymorphic ventricular tachyarrhythmia. CONCLUSION: Despite a profound alteration in K+ currents, repolarization is uniformly prolonged in this model with no proclivity to develop bradycardia-dependent arrhythmias.

Integrity signals

Registry

Crossref · 10.1016/s0008-6363(02)00236-5

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lacroix, D.
Affiliations
Université de Lille (FR)
Corresponding author
Lacroix, D
Venue
Cardiovascular Research
Published
2002-04
Volume
54
Issue
1
Pages
42-50
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2081347317
Cited by
37
References
29
Citations by year
2025: 1 · 2023: 1 · 2021: 1 · 2019: 3 · 2018: 1 · 2017: 3 · 2016: 1 · 2015: 4 · 2013: 3 · 2012: 1
FWCI
1.97
Type
journal article
Language
en
Open access
closed
Locations
  • Cardiovascular Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
Keywords
repolarization abnormalities, pacing-induced cardiomyopathy, heart failure, action potential prolongation, delayed rectifier potassium current, transient outward potassium current, transmural dispersion of repolarization, activation-recovery interval, ventricular arrhythmias, QT interval, potassium currents, porcine model, tachycardia-induced cardiomyopathy, arrhythmogenesis, long QT syndrome
MeSH terms
Action Potentials, Analysis of Variance, Animals, Cardiac Pacing, Artificial, Electrocardiography, Heart Failure, Long QT Syndrome, Perfusion, Swine, Patch-Clamp Techniques, Ventricular Remodeling, Models, Animal, Potassium Channels, Inwardly Rectifying, In Vitro Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review