The pressures in the episcleral veins, Schlemm's canal and the trabecular meshwork in monkeys: Effects of changes in intraocular pressure
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The pressures in the episcleral veins, Schlemm's canal and the trabecular meshwork were studied with a micropuncture technique using cannulas with tip diameters of less than 5 microns. The pressure in Schlemm's canal, Psc, was 14.3 +/- 1.0 cmH2O at spontaneous intraocular pressure, IOP, 19.2 +/- 0.9 cmH2O. The outflow pressure from the anterior chamber to Schlemm's canal was 4.9 +/- 0.7 cmH2O. The relationship between pressures was IOP = 0.73 Psc + 8.7. When the intraocular pressure was increased stepwise from the spontaneous level to 30 cmH2O there was an increase in pressure in Schlemm's canal of 1.7 +/- 0.6 cmH2O, (P less than 0.05). The total outflow resistance and the resistance between the anterior chamber and Schlemm's canal were 3.27 +/- 0.43 and 2.92 +/- 0.50 cmH2O min microliter-1 respectively for the intraocular pressure interval between the spontaneous pressure and a level 4-11 cmH2O higher. In the intraocular pressure range from 20 to 30 cmH2O the corresponding figures were 2.89 +/- 0.45 and 2.69 +/- 0.42 cmH2O min microliter-1 and for the pressure range 25-35 cmH2O, 2.48 +/- 0.58 and 2.31 +/- 0.59 cmH2O min microliter-1. The difference between the total outflow resistance and that between the anterior chamber and Schlemm's canal was about 10% of the total at intraocular pressures below 35 cmH2O. Stepwise increments in IOP increased the trabecular meshwork pressure by 0.88 cmH2O for each cmH2O increase in IOP in the interval of 30-50 cmH2O. The total outflow resistance and the resistance between the anterior chamber and the tip of the microcannula was 3.91 +/- 1.53 and 1.94 +/- 0.99 cmH2O min microliter-1 respectively for the intraocular pressure interval between the spontaneous pressure and 30 cmH2O. In the interval between 30 and 45 cmH2O the corresponding figures were 2.16 +/- 0.66 and 0.20 +/- 0.13 cmH2O min microliter-1. The episcleral venous pressure at the spontaneous intraocular pressure was 14.1 +/- 1.0 cmH2O in seven animals with minimal trauma, and 12.3 +/- 0.8 cmH2O in animals after cannulation of Schlemm's canal. The outflow pressure from the anterior chamber to the episcleral veins was 4.4 +/- 1.2 cmH2O in animals with minimal trauma and 7.1 +/- 0.8 cmH2O after cannulation of Schlemm's canal. The relationship between pressures was IOP = 0.68EVP + 11.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MAGOUN, H. N. (1965) · The Journal of Nervous and Mental Disease · doi:10.1097/00005053-196504000-00011 · Cited by 2,930
Experimental Aqueous Perfusion in Enucleated Human Eyes
GRANT, W. M. (1963) · Archives of Ophthalmology · doi:10.1001/archopht.1963.00960040789022 · Cited by 538
Blood circulation and fluid dynamics in the eye
Bill, A. (1975) · Physiological Reviews · doi:10.1152/physrev.1975.55.3.383 · Cited by 468
Self-citationPulsatile pressures in the microcirculation of frog's mesentery
Wiederhielm, C. A., Woodbury, J. W., Kirk, S., & Rushmer, R. F. (1964) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1964.207.1.173 · Cited by 439
Uveoscleral drainage of aqueous humour in human eyes
Bill, A., & Phillips, C. I. (1971) · Experimental Eye Research · doi:10.1016/0014-4835(71)90149-7 · Cited by 347
Self-citationBárány, E. H. (1964) · PubMed · Cited by 257
Kaufman, P. L. P., & Bárány, E. H. (1976) · PubMed · Cited by 214
Inomata, H., Bill, A., & Smelser, G. K. (1972) · American Journal of Ophthalmology · doi:10.1016/0002-9394(72)90394-7 · Cited by 187
Self-citationAqueous humor dynamics in monkeys (Macaca irus and Cercopithecus ethiops)
Bill, A. (1971) · Experimental Eye Research · doi:10.1016/s0014-4835(71)80023-4 · Cited by 94
Self-citationInfluence of intraocular pressure and trabeculotomy on aqueous outflow in enucleated monkey eyes.
Ellingsen, B. A., & Grant, W. M. (1971) · PubMed · Cited by 59
Cited by
Aqueous Humor Dynamics: A Review
Goel, M., Picciani, R. G., Lee, R. K., & Bhattacharya, S. K. (2010) · The Open Ophthalmology Journal · doi:10.2174/1874364101004010052 · Cited by 882
‘What controls aqueous humour outflow resistance?’
Johnson, M. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2005.10.011 · Cited by 482
Pressures in the juxtacanalicular tissue and Schlemm's canal in monkeys
Mäepea, O., & Bill, A. (1992) · Experimental Eye Research · doi:10.1016/0014-4835(92)90151-h · Cited by 290
Self-citationOcular Biomechanics and Biotransport
Ethier, C. R., Johnson, M., & Ruberti, J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140055 · Cited by 288
Overby, D. R., Stamer, W. D., & Johnson, M. (2009) · Experimental Eye Research · doi:10.1016/j.exer.2008.11.033 · Cited by 263
Effects of glucocorticoids on the trabecular meshwork: towards a better understanding of glaucoma
Wordinger, R. J., & Clark, A. F. (1999) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(98)00035-4 · Cited by 260
Introductory biomechanics: from cells to organisms
(2007) · Choice Reviews Online · doi:10.5860/choice.45-1476 · Cited by 241
Unconventional aqueous humor outflow: A review
Johnson, M., McLaren, J. W., & Overby, D. R. (2017) · Experimental Eye Research · doi:10.1016/j.exer.2016.01.017 · Cited by 221
Oh, D.-J., Kang, M. H., Ooi, Y. H., Choi, K. R., Sage, E. H., & Rhee, D. J. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-11362 · Cited by 58
Metadata
- Authors
- Mäepea, O., & Bill, A.
- Venue
- Experimental Eye Research
- Publisher
- Elsevier BV
- Published
- 1989-10
- Volume
- 49
- Issue
- 4
- Pages
- 645-663
- ISSN
- 0014-4835 (ISSN-L)
- OpenAlex
- W2072121293
- Cited by
- 169
- References
- 11
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.