The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Aqueous Humor Dynamics: A Review
Open accessAbstract
Glaucoma is a family of optic neuropathies which cause irreversible but potentially preventable vision loss. Vision loss in most forms of glaucoma is related to elevated IOP with subsequent injury to the optic nerve. Secretion of aqueous humor and regulation of its outflow are physiologically important processes for maintaining IOP in the normal range. Thus, understanding the complex mechanisms that regulate aqueous humor circulation is essential for management of glaucoma. The two main structures related to aqueous humor dynamics are the ciliary body and the trabecular meshwork (TM). Three mechanisms are involved in aqueous humor formation: diffusion, ultrafiltration and active secretion. Active secretion is the major contributor to aqueous humor formation. The aqueous humor flow in humans follows a circadian rhythm, being higher in the morning than at night. The aqueous humor leaves the eye by passive flow via two pathways - the trabecular meshwork and the uveoscleral pathway. In humans, 75% of the resistance to aqueous humor outflow is localized within the TM with the juxtacanalicular portion of the TM being the main site of outflow resistance. Glycosaminoglycan deposition in the TM extracellular matrix (ECM) has been suggested to be responsible for increased outflow resistance at this specific site whereas others have suggested deposition of proteins, such as cochlin, obstruct the aqueous humor outflow through the TM. The uveoscleral outflow pathway is relatively independent of the intraocular pressure and the proportion of aqueous humor exiting the eye via the uveoscleral pathway decreases with age.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A family of mammalian Na+-dependent L-ascorbic acid transporters
Tsukaguchi, H., Tokui, T., Mackenzie, B., Berger, U. V., Chen, X.-Z., Wang, Y., Brubaker, R. F., & Hediger, M. A. (1999) · Nature · doi:10.1038/19986 · Cited by 882
Immunoglobulins in the Human Eye: Location, Type, and Amount
Allansmith, M. R. (1973) · Archives of Ophthalmology · doi:10.1001/archopht.1973.01000040038010 · Cited by 103
Cited by
Aqueous outflow - A continuum from trabecular meshwork to episcleral veins
Carreon, T., van der Merwe, E., Fellman, R. L., Johnstone, M., & Bhattacharya, S. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.12.004 · Cited by 312
Self-citationAn ocular glymphatic clearance system removes β-amyloid from the rodent eye
Wang, X., Lou, N., Eberhardt, A., Yang, Y., Kusk, P., Xu, Q., Förstera, B., Peng, S., Shi, M., Ladrón-de-Guevara, A., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw3210 · Cited by 239
Ryskamp, D. A., Frye, A. M., Phuong, T. T. T., Yarishkin, O., Jo, A. O., Xu, Y., Lakk, M., Iuso, A., Redmon, S. N., Ambati, B., et al. (2016) · Scientific Reports · doi:10.1038/srep30583 · Cited by 139
Compartmentalized ocular lymphatic system mediates eye–brain immunity
Yin, X., Zhang, S., Lee, J. H., Dong, H., Mourgkos, G., Terwilliger, G., Kraus, A., Geraldo, L. H., Poulet, M., Fischer, S., et al. (2024) · Nature · doi:10.1038/s41586-024-07130-8 · Cited by 108
Implications of genetic variation in the complement system in age-related macular degeneration
de Jong, S., Gagliardi, G., Garanto, A., de Breuk, A., Lechanteur, Y. T. E., Katti, S., van den Heuvel, L. P., Volokhina, E. B., & den Hollander, A. I. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2021.100952 · Cited by 71
Metadata
- Authors
- Goel, M., Picciani, R. G., Lee, R. K., & Bhattacharya, S. K.
- Venue
- The Open Ophthalmology Journal
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2010-09-03
- Volume
- 4
- Issue
- 1
- Pages
- 52-59
- ISSN
- 1874-3641 (ISSN-L)
- OpenAlex
- W2171679548
- Cited by
- 882
- References
- 2
- FWCI
- 13.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aqueous Humor Dynamics: A Review. https://app.cochat.ai/papers/10.2174/1874364101004010052
- The paper
- Goel, M., Picciani, R. G., Lee, R. K., & Bhattacharya, S. K. (2010). Aqueous Humor Dynamics: A Review. The Open Ophthalmology Journal. https://doi.org/10.2174/1874364101004010052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.