CoChat

The pressures in the episcleral veins, Schlemm's canal and the trabecular meshwork in monkeys: Effects of changes in intraocular pressure

Open access
Mäepea, Olav, Bill, Anders · 1989 · Experimental Eye Research
Cited by 169

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

The pressures in the episcleral veins, Schlemm's canal and the trabecular meshwork were studied with a micropuncture technique using cannulas with tip diameters of less than 5 microns. The pressure in Schlemm's canal, Psc, was 14.3 +/- 1.0 cmH2O at spontaneous intraocular pressure, IOP, 19.2 +/- 0.9 cmH2O. The outflow pressure from the anterior chamber to Schlemm's canal was 4.9 +/- 0.7 cmH2O. The relationship between pressures was IOP = 0.73 Psc + 8.7. When the intraocular pressure was increased stepwise from the spontaneous level to 30 cmH2O there was an increase in pressure in Schlemm's canal of 1.7 +/- 0.6 cmH2O, (P less than 0.05). The total outflow resistance and the resistance between the anterior chamber and Schlemm's canal were 3.27 +/- 0.43 and 2.92 +/- 0.50 cmH2O min microliter-1 respectively for the intraocular pressure interval between the spontaneous pressure and a level 4-11 cmH2O higher. In the intraocular pressure range from 20 to 30 cmH2O the corresponding figures were 2.89 +/- 0.45 and 2.69 +/- 0.42 cmH2O min microliter-1 and for the pressure range 25-35 cmH2O, 2.48 +/- 0.58 and 2.31 +/- 0.59 cmH2O min microliter-1. The difference between the total outflow resistance and that between the anterior chamber and Schlemm's canal was about 10% of the total at intraocular pressures below 35 cmH2O. Stepwise increments in IOP increased the trabecular meshwork pressure by 0.88 cmH2O for each cmH2O increase in IOP in the interval of 30-50 cmH2O. The total outflow resistance and the resistance between the anterior chamber and the tip of the microcannula was 3.91 +/- 1.53 and 1.94 +/- 0.99 cmH2O min microliter-1 respectively for the intraocular pressure interval between the spontaneous pressure and 30 cmH2O. In the interval between 30 and 45 cmH2O the corresponding figures were 2.16 +/- 0.66 and 0.20 +/- 0.13 cmH2O min microliter-1. The episcleral venous pressure at the spontaneous intraocular pressure was 14.1 +/- 1.0 cmH2O in seven animals with minimal trauma, and 12.3 +/- 0.8 cmH2O in animals after cannulation of Schlemm's canal. The outflow pressure from the anterior chamber to the episcleral veins was 4.4 +/- 1.2 cmH2O in animals with minimal trauma and 7.1 +/- 0.8 cmH2O after cannulation of Schlemm's canal. The relationship between pressures was IOP = 0.68EVP + 11.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0014-4835(89)80060-0

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 169

Metadata

Authors
Mäepea, O., & Bill, A.
Venue
Experimental Eye Research
Publisher
Elsevier BV
Published
1989-10
Volume
49
Issue
4
Pages
645-663
ISSN
0014-4835 (ISSN-L)
OpenAlex
W2072121293
Cited by
169
References
11
FWCI
2.45
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.