Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Appropriate technology: antenatal care

Lumbiganon, P. · 1998 · International Journal of Gynecology & Obstetrics

Abstract

Appropriate health technology should be effective, safe and feasible. The current antenatal care model originated from western countries. The absence of direct randomized, controlled trials precludes a straight forward evaluation of the impact of prenatal care on birth outcomes. Interventions of proven benefits in eliminating or alleviating adverse maternal outcomes include routine iron and folate supplementation in areas of high anemia prevalence, hemoglobin determination late in pregnancy, screening for asymptomatic bacteriuria by urine culture or dipstick, serologic screening and treatment of syphilis, obtaining a history of difficult labor in multipara or height in nullipara and external cephalic version at term. Interventions of proven benefits in eliminating or alleviating adverse newborn outcomes include routine measurement of fundal height, reduction of maternal physical strain, diagnosis and treatment of tuberculosis, malaria prophylaxis, adequate tetanus immunization, antenatal and perinatal Zidovudine in HIV‐positive mothers and one vaginal examination during pregnancy. Only these interventions of proven benefits should be implemented.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0020-7292(98)00189-1

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 30 references

Cited by

See all 30

Metadata

Authors
Lumbiganon, P.
Affiliations
Khon Kaen University (TH)
Corresponding author
Lumbiganon, P.
Venue
International Journal of Gynecology & Obstetrics
Publisher
Wiley
Published
1998-12
Volume
63
Issue
S1
Pages
S91-5
ISSN
  • 0020-6695 (ISSN-L)
  • 0020-7292
  • 1879-3479
OpenAlex
W2061991329
Cited by
29
References
30
Citations by year
2018: 2 · 2017: 1 · 2016: 1 · 2015: 3 · 2014: 2 · 2013: 1 · 2012: 1
FWCI
1.16
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Gynecology & Obstetrics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Global Maternal and Child Health
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Maternal and Neonatal Healthcare
  • Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
Keywords
prenatal care, prenatal screening, iron and folic acid supplementation, anemia in pregnancy, hemoglobin measurement, bacteriuria screening, syphilis screening, external cephalic version, fundal height measurement, maternal tuberculosis, malaria prophylaxis, tetanus vaccination, adverse maternal outcomes
MeSH terms
Developing Countries, Female, Humans, Infant Welfare, Infant, Newborn, Pregnancy, Pregnancy Complications, Pregnancy Outcome, Prenatal Care, Reproductive Techniques, Technology Assessment, Biomedical, Thailand, Randomized Controlled Trials as Topic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Appropriate technology: antenatal care. https://app.cochat.ai/papers/10.1016/s0020-7292(98)00189-1
The paper
Lumbiganon, P. (1998). Appropriate technology: antenatal care. International Journal of Gynecology & Obstetrics. https://doi.org/10.1016/s0020-7292(98)00189-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.