The DOI matches its Crossref record.
Fluorescent excitation transfer immunoassay. A general method for determination of antigens.
Open accessAbstract
A general immunochemical method for the assay of haptens and proteins has been devised and applied to morphine, a morphine-albumin conjugate, and human immunoglobulin G. A fluorescein-labeled antigen and a quencher-labeled antibody are employed. By use of fluorescein and rhodamine as the fluorescer and quencher, respectively, dipole-dipole-coupled excitation energy transfer can occur within the antigen-antibody complex. The resulting quenching of fluorescence can be inhibited by competitive binding with unlabeled antigen, Alternatively, separate antibody samples can be labeled with fluorescein and rhodamine, respectively. Unlabeled antigen causes aggregation of the separately labeled components with resultant quenching. Using the latter method, experiments suggest that up to about 20 anti-morphine antibody binding sites will associate with morphine-albumin conjugates. When an excess of the conjugate is present the antibodies appear to assemble in clumps on the protein surface. Mathematical analysis of the quenching of fluorescein-labeled morphine by rhodamine-labeled anti-morphine gives an approximate fit to the quenching data, but the calculations are very dependent on the assumptions used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Radiative Decay Engineering: Biophysical and Biomedical Applications
Lakowicz, J. R. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5377 · Cited by 1,217
Tumor biomarkers for diagnosis, prognosis and targeted therapy
Zhou, Y., Tao, L., Qiu, J., Xu, J., Yang, X., Zhang, Y., Tian, X., Guan, X., Cen, X., & Zhao, Y. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01823-2 · Cited by 720
Plasmon-controlled fluorescence: a new paradigm in fluorescence spectroscopy
Lakowicz, J. R., Ray, K., Chowdhury, M., Szmacinski, H., Fu, Y., Zhang, J., & Nowaczyk, K. (2008) · The Analyst · doi:10.1039/b802918k · Cited by 640
Mathis, G. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.9.1391 · Cited by 339
Metadata
- Authors
- Ullman, E. F., Schwarzberg, M., & Rubenstein, K. E.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1976-07
- Volume
- 251
- Issue
- 14
- Pages
- 4172-4178
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1537526970
- Cited by
- 206
- References
- 0
- FWCI
- 6.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescent excitation transfer immunoassay. A general method for determination of antigens. https://app.cochat.ai/papers/10.1016/s0021-9258(17)33277-5
- The paper
- Ullman, E. F., Schwarzberg, M., & Rubenstein, K. E. (1976). Fluorescent excitation transfer immunoassay. A general method for determination of antigens. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(17)33277-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.