Fluorescent excitation transfer immunoassay. A general method for determination of antigens.
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A general immunochemical method for the assay of haptens and proteins has been devised and applied to morphine, a morphine-albumin conjugate, and human immunoglobulin G. A fluorescein-labeled antigen and a quencher-labeled antibody are employed. By use of fluorescein and rhodamine as the fluorescer and quencher, respectively, dipole-dipole-coupled excitation energy transfer can occur within the antigen-antibody complex. The resulting quenching of fluorescence can be inhibited by competitive binding with unlabeled antigen, Alternatively, separate antibody samples can be labeled with fluorescein and rhodamine, respectively. Unlabeled antigen causes aggregation of the separately labeled components with resultant quenching. Using the latter method, experiments suggest that up to about 20 anti-morphine antibody binding sites will associate with morphine-albumin conjugates. When an excess of the conjugate is present the antibodies appear to assemble in clumps on the protein surface. Mathematical analysis of the quenching of fluorescein-labeled morphine by rhodamine-labeled anti-morphine gives an approximate fit to the quenching data, but the calculations are very dependent on the assumptions used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331
Zwischenmolekulare Energiewanderung und Fluoreszenz
Förster, T. (1948) · Annalen der Physik · doi:10.1002/andp.19484370105 · Cited by 8,285
Intermolecular energy transfer and fluorescence.
Förster, T. (1948) · Medical Entomology and Zoology · Cited by 687
“Homogeneous” enzyme immunoassay. A new immunochemical technique
Rubenstein, K. E., Schneider, R. S., & Ullman, E. F. (1972) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(72)90570-0 · Cited by 498
Self-citationBRANDTZAEG, P. (1973) · Scandinavian Journal of Immunology · doi:10.1111/j.1365-3083.1973.tb02037.x · Cited by 289
Rapid Fluorescein and Protein Assay Method for Fluorescent-Antibody Conjugates
Wells, A. F., Miller, C. E., & Nadel, M. K. (1966) · Applied Microbiology · doi:10.1128/aem.14.2.271-275.1966 · Cited by 157
Spin Immunoassay Technique for Determination of Morphine
Leute, R., Ullman, E. F., Goldstein, A., & Herzenberg, L. A. (1972) · Nature New Biology · doi:10.1038/newbio236093a0 · Cited by 139
Self-citation
Cited by
Radiative Decay Engineering: Biophysical and Biomedical Applications
Lakowicz, J. R. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5377 · Cited by 1,217
Tumor biomarkers for diagnosis, prognosis and targeted therapy
Zhou, Y., Tao, L., Qiu, J., Xu, J., Yang, X., Zhang, Y., Tian, X., Guan, X., Cen, X., & Zhao, Y. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01823-2 · Cited by 720
Plasmon-controlled fluorescence: a new paradigm in fluorescence spectroscopy
Lakowicz, J. R., Ray, K., Chowdhury, M., Szmacinski, H., Fu, Y., Zhang, J., & Nowaczyk, K. (2008) · The Analyst · doi:10.1039/b802918k · Cited by 640
Mathis, G. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.9.1391 · Cited by 339
Membrane Association and Protein Conformation of α-Synuclein in Intact Neurons
McLean, P. J., Kawamata, H., Ribich, S., & Hyman, B. T. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.275.12.8812 · Cited by 244
Szöllosi, J., Damjanovich, S., & Mátyus, L. (1998) · Cytometry · doi:10.1002/(sici)1097-0320(19980815)34:4<159::aid-cyto1>3.3.co;2-9 · Cited by 214
Mayilo, S., Kloster, M. A., Wunderlich, M., Lutich, A., Klar, T. A., Nichtl, A., Kürzinger, K., Stefani, F. D., & Feldmann, J. (2009) · Nano Letters · doi:10.1021/nl903178n · Cited by 213
Luminescent Labels—More than Just an Alternative to Radioisotopes?
Mayer, A., & Neuenhofer, S. (1994) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199410441 · Cited by 203
Morrison, L. E., Halder, T. C., & Stols, L. M. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90473-9 · Cited by 168
The use of phycobiliproteins as fluorescent labels in immunoassay
Kronick, M. N. (1986) · Journal of Immunological Methods · doi:10.1016/0022-1759(86)90496-5 · Cited by 161
Metadata
- Authors
- Ullman, E. F., Schwarzberg, M., & Rubenstein, K. E.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1976-07
- Volume
- 251
- Issue
- 14
- Pages
- 4172-4178
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1537526970
- Cited by
- 206
- References
- 7
- FWCI
- 6.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.