Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 362

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

THE USE OF ANTIPYRINE IN THE MEASUREMENT OF TOTAL BODY WATER IN MAN

Open access
Soberman, Robert., Brodie, Bernard B., Levy, Betty B., Axelrod, Julius., Hollander, Vincent., Steele, J. Murray·1949·Journal of Biological Chemistry

Abstract

Most methods for measuring the total water content of the body in viva have been based on the degree of dilution of a foreign substance after its intravenous injection.These methods, recently reviewed by Pace (l), are in general unsatisfactory because the substances employed are not distributed evenly throughout the water of the body.Exceptions to this criticism are deuterium and tritium oxides (l-3), which presumably are distributed throughout the body like ordinary water.However, the costliness of these compounds and the complicated apparatus and techniques involved in their measurement make their use inconvenient.The proportion of water in the body may also be calculated from the subject's specific gravity (4), but this measurement is also laborious (5, 6) and there remains a need for a simple and accurate measure of body water.For measurements of body water a substance should possess the following characteristics: (1) even and rapid distribution throughout body water; (2) non-toxicity in required doses; (3) slow transformation in, and slow excretion from, the body; (4) accurate and convenient estimation of its concentration in the plasma.Prior studies in this laboratory on the distribution of antipyrine (lphenyl-2,3-dimethylpyrazolone-5-one) in the dog indicated that it was distributed in tissues in proportion to their water content.'The possibility that antipyrine might be used in the measurement of total body water in vivo was therefore explored, and the results indicate that antipyrine fulfills the above requirements to a reasonably satisfactory degree.Methods-Antipyrine in biological material was measured by a method previously reported (7).Deuterium oxide in plasma was measured by a modification of the method of Keston, Rittenberg, and Schoenheimer (8).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0021-9258(18)56808-3

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 362

Metadata

Authors
Soberman, R., Brodie, B. B., Levy, B. B., Axelrod, J., Hollander, V., & Steele, J. M.
Venue
Journal of Biological Chemistry
Publisher
Elsevier BV
Published
1949-05
Volume
179
Issue
1
Pages
31-42
ISSN
0021-9258 (ISSN-L)
OpenAlex
W1519637961
Cited by
362
References
7
FWCI
26.79
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: THE USE OF ANTIPYRINE IN THE MEASUREMENT OF TOTAL BODY WATER IN MAN. https://app.cochat.ai/papers/10.1016/s0021-9258(18)56808-3
The paper
Soberman, R., Brodie, B. B., Levy, B. B., Axelrod, J., Hollander, V., & Steele, J. M. (1949). THE USE OF ANTIPYRINE IN THE MEASUREMENT OF TOTAL BODY WATER IN MAN. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)56808-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.