The DOI matches its Crossref record.
THE DETERMINATION OF BILIRUBIN WITH THE PHOTOELECTRIC COLORIMETER
Open accessAbstract
The main source of error in the determination of bilirubin in serum by the diazo reaction has been the loss caused by adsorption on the protein precipitate. In addition, the lack of an accurately matching artificial standard and the sensitivity of the azobilirubin color to changes in pH have made accurate calorimetric determinations impossible, without the aid of some type of objective photometer such as the spectrophotometer, the Pulfrich photometer, or the photoelectric calorimeter (14). In this paper we shall describe a method for the quantitative determination of both direct and indirect bilirubin in serum, in which protein precipitation and consequent loss of bilirubin have been eliminated. By a slight modification of the method, a quantitative study of the behavior of the direct, reaction has also been made possible. Artificial standards have been eliminated in the calorimetric determinations by the use of the photoelectric colorimeter (5) with a specially selected light filter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Tenhunen, R., Marver, H. S., & Schmid, R. (1969) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)63477-5 · Cited by 1,357
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Effect of peptide YY on gastric, pancreatic, and biliary function in humans
Adrian, T. E., Savage, A. P., Sagor, G. R., Allen, J. M., Bacarese-Hamilton, A. J., Tatemoto, K., Polak, J. M., & Bloom, S. R. (1985) · Gastroenterology · doi:10.1016/0016-5085(85)90442-1 · Cited by 277
Achliya, G. S., Wadodkar, S. G., & Dorle, A. K. (2004) · Journal of Ethnopharmacology · doi:10.1016/j.jep.2003.09.037 · Cited by 192
Metadata
- Authors
- Malloy, H. T., & Evelyn, K. A.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1937-07
- Volume
- 119
- Issue
- 2
- Pages
- 481-490
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1554188337
- Cited by
- 1,617
- References
- 0
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: THE DETERMINATION OF BILIRUBIN WITH THE PHOTOELECTRIC COLORIMETER. https://app.cochat.ai/papers/10.1016/s0021-9258(18)74392-5
- The paper
- Malloy, H. T., & Evelyn, K. A. (1937). THE DETERMINATION OF BILIRUBIN WITH THE PHOTOELECTRIC COLORIMETER. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)74392-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.