Smooth and skeletal muscle myosin both exhibit low duty cycles at zero load in vitro
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Smooth muscle's stress equals that of skeletal muscle with less myosin. Thus, under isometric conditions, smooth muscle myosin may spend a greater fraction of its cycle time attached to actin in a high force state (i.e. higher duty cycle). If so, then smooth muscle myosin may also have a higher duty cycle under unloaded conditions. To test this, we used an in vitro motility assay in which fluorescently labeled actin filaments move freely over a sparsely coated (5-100 micrograms/ml) myosin surface. Actin filament velocity (V) was a function of the number of cross-bridges capable of interacting with an actin filament (N) and the duty cycle (f), V = (a x Vmax) x (1-(1-f)N) (Uyeda et al., 1990; Harada et al., 1990). N was estimated from the myosin density on the motility surface and the actin filament length. Data for V versus N were fit to the above equation to predict f. The duty cycle of smooth muscle myosin (4.0 +/- 0.7%) was not significantly different from that of skeletal muscle myosin (3.8 +/- 0.5%) in agreement with values estimated by Uyeda et al. (1990) for skeletal muscle myosin under unloaded conditions. The duty cycles of smooth and skeletal muscle myosin may still differ under isometric conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A MICROCOLORIMETRIC METHOD FOR THE DETERMINATION OF INORGANIC PHOSPHORUS
Taussky, H. H., Shorr, E., & Kurzmann, G. (1953) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)66180-0 · Cited by 2,582
Huxley, H. E. (1969) · Science · doi:10.1126/science.164.3886.1356 · Cited by 1,959
[18] Purification of muscle actin
Pardee, J. D., & Aspudich, J. (1982) · Methods in Enzymology · doi:10.1016/0076-6879(82)85020-9 · Cited by 1,186
Bead movement by single kinesin molecules studied with optical tweezers
Block, S. M., Goldstein, L. S. B., & Schnapp, B. J. (1990) · Nature · doi:10.1038/348348a0 · Cited by 1,038
Movement of microtubules by single kinesin molecules
Howard, J., Hudspeth, A. J., & Vale, R. D. (1989) · Nature · doi:10.1038/342154a0 · Cited by 885
Fluorescent actin filaments move on myosin fixed to a glass surface.
Kron, S. J., & Spudich, J. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.17.6272 · Cited by 853
Force measurements by micromanipulation of a single actin filament by glass needles
Kishino, A., & Yanagida, T. (1988) · Nature · doi:10.1038/334074a0 · Cited by 679
Mechanochemical coupling in actomyosin energy transduction studied by in vitro movement assay
Harada, Y., Sakurada, K., Aoki, T., Thomas, D. D., & Yanagida, T. (1990) · Journal of Molecular Biology · doi:10.1016/s0022-2836(05)80060-9 · Cited by 522
Movement of myosin-coated fluorescent beads on actin cables in vitro
Sheetz, M. P., & Spudich, J. A. (1983) · Nature · doi:10.1038/303031a0 · Cited by 511
Myosin Structure and Function in Cell Motility
Warrick, H. M., & Spudich, J. A. (1987) · Annual Review of Cell Biology · doi:10.1146/annurev.cb.03.110187.002115 · Cited by 482
Cited by
Mechanics of actomyosin bonds in different nucleotide states are tuned to muscle contraction
Guo, B., & Guilford, W. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0601255103 · Cited by 277
Kinetic Mechanism of Non-muscle Myosin IIB
Wang, F., Kovács, M., Hu, A., Limouze, J., Harvey, E. V., & Sellers, J. R. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m302510200 · Cited by 253
Functional Divergence of Human Cytoplasmic Myosin II
Kovács, M., Wang, F., Hu, A., Zhang, Y., & Sellers, J. R. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m305453200 · Cited by 249
Tyska, M. J., & Warshaw, D. M. (2002) · Cell Motility · doi:10.1002/cm.10014 · Cited by 199
Self-citationTwo heads of myosin are better than one for generating force and motion
Tyska, M. J., Dupuis, D. E., Guilford, W. H., Patlak, J. B., Waller, G. S., Trybus, K. M., Warshaw, D. M., & Lowey, S. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.8.4402 · Cited by 196
Self-citationCardiac V 1 And V 3 Myosins Differ in Their Hydrolytic and Mechanical Activities In Vitro
VanBuren, P., Harris, D. E., Alpert, N. R., & Warshaw, D. M. (1995) · Circulation Research · doi:10.1161/01.res.77.2.439 · Cited by 176
Self-citationForce Generation in Single Conventional Actomyosin Complexes under High Dynamic Load
Takagi, Y., Homsher, E. E., Goldman, Y. E., & Shuman, H. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.068429 · Cited by 162
“05 mg/ml of rabbit skeletal muscle myosin for 10 min, 2 mg/ml BSA in Buffer A for 10 min (32), sheared actin (5 mM; sheared 10 times using a 27G 1/2$ needle attached to a 1 ml syringe) for 10 min, 1 mM ATP in Buffer A for 3 min (32), and then Buffer A for 1 min (34).”
Method
Metadata
- Authors
- Harris, D. E., & Warshaw, D. M.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1993-07
- Volume
- 268
- Issue
- 20
- Pages
- 14764-14768
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1561116581
- Cited by
- 165
- References
- 29
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.