Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record.

Material characterization of the brainstem from oscillatory shear tests

Open access
Arbogast, Kristy B, Margulies, Susan S·1998·Journal of Biomechanics

Abstract

Traumatic damage to the brainstem occurs frequently when the brain skull complex experiences injurious loading especially during those traumatic situations that produce diffuse axonal injury (DAI). DAI has been shown to be dependent on load direction and correlated with regional tissue deformation in response to rotational inertial loads. Possible mechanisms for the selective vulnerability of the brainstem are (1) the geometry of the central nervous system is responsible for producing high tissue strains in these regions, (2) regional differences in overall material stiffness result in larger deformations at these sites, and (3) the anisotropic mechanical properties of these regions lead to a sensitivity to the rotational load direction and magnitude. This paper investigates the latter two hypotheses by performing oscillatory shear tests on adult porcine brainstem in three mutually perpendicular directions. The complex shear moduli were calculated over a range of frequencies (20-200 Hz), for three levels of peak engineering strain (2.5%, 5.0%, and 7.5%). The directional data demonstrated that the brainstem exhibits significant transversely isotropic behavior. Both components of the complex modulus in which the axonal fibers are oriented parallel to the plane of shear but transverse to the shear direction were significantly higher than those of the other two, mutually indistinguishable test cases across the range of strains tested. By comparison with similar tests on cerebral tissue, these data demonstrated that the brainstem displays a stiffer biomechanical response. These differences were present for both components of the complex shear modulus and were greater as the magnitude of the applied strain increased. The regional stiffness and anisotropic response of the brainstem coupled with its location as a narrow bridge between CNS regions interact to result in the selective vulnerability of this region in rotational loading.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0021-9290(98)00068-2

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 225

Metadata

Authors
Arbogast, K. B., & Margulies, S. S.
Venue
Journal of Biomechanics
Publisher
Elsevier BV
Published
1998-09
Volume
31
Issue
9
Pages
801-807
ISSN
0021-9290 (ISSN-L)
OpenAlex
W2152099356
Cited by
225
References
0
FWCI
1.09
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Material characterization of the brainstem from oscillatory shear tests. https://app.cochat.ai/papers/10.1016/s0021-9290(98)00068-2
The paper
Arbogast, K. B., & Margulies, S. S. (1998). Material characterization of the brainstem from oscillatory shear tests. Journal of Biomechanics. https://doi.org/10.1016/s0021-9290(98)00068-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.