Material characterization of the brainstem from oscillatory shear tests
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Traumatic damage to the brainstem occurs frequently when the brain skull complex experiences injurious loading especially during those traumatic situations that produce diffuse axonal injury (DAI). DAI has been shown to be dependent on load direction and correlated with regional tissue deformation in response to rotational inertial loads. Possible mechanisms for the selective vulnerability of the brainstem are (1) the geometry of the central nervous system is responsible for producing high tissue strains in these regions, (2) regional differences in overall material stiffness result in larger deformations at these sites, and (3) the anisotropic mechanical properties of these regions lead to a sensitivity to the rotational load direction and magnitude. This paper investigates the latter two hypotheses by performing oscillatory shear tests on adult porcine brainstem in three mutually perpendicular directions. The complex shear moduli were calculated over a range of frequencies (20-200 Hz), for three levels of peak engineering strain (2.5%, 5.0%, and 7.5%). The directional data demonstrated that the brainstem exhibits significant transversely isotropic behavior. Both components of the complex modulus in which the axonal fibers are oriented parallel to the plane of shear but transverse to the shear direction were significantly higher than those of the other two, mutually indistinguishable test cases across the range of strains tested. By comparison with similar tests on cerebral tissue, these data demonstrated that the brainstem displays a stiffer biomechanical response. These differences were present for both components of the complex shear modulus and were greater as the magnitude of the applied strain increased. The regional stiffness and anisotropic response of the brainstem coupled with its location as a narrow bridge between CNS regions interact to result in the selective vulnerability of this region in rotational loading.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical model simulations of brain injury in the primate
Margulies, S. S., Thibault, L. E., & Gennarelli, T. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90029-3 · Cited by 385 · cited 6×
“Previous studies have demonstrated that DAI is correlated with regional tissue deformation in”
InfluentialSelf-citationA viscoelastic study of scalp, brain, and dura
Galford, J. E., & McElhaney, J. H. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90007-2 · Cited by 347 · cited 1×
“Most other experimentally determined CNS tissue material properties have measured the isotropic response of human cerebral hemispheres (Donnelly et al., 1997; Fallenstein et al., 1969; Galford and McElhaney, 1970; Shuck and Advani, 1972).”
BackgroundRheological Response of Human Brain Tissue in Shear
Shuck, L. Z., & Advani, S. H. (1972) · Journal of Basic Engineering · doi:10.1115/1.3425588 · Cited by 308 · cited 4×
“Oscillatory shear testing techniques have been used previously to provide a measurement of the complex modulus of cerebral tissue (Fallenstein et al., 1969; Shuck and Advani, 1972); however, no similar tests have investigated the mechanical response of the brainstem.”
MethodInfluentialDynamic mechanical properties of human brain tissue
Fallenstein, G. T., Hulce, V. D., & Melvin, J. W. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90079-7 · Cited by 288 · cited 2×
“Oscillatory shear testing techniques have been used previously to provide a measurement of the complex modulus of cerebral tissue (Fallenstein et al., 1969; Shuck and Advani, 1972); however, no similar tests have investigated the mechanical response of the brainstem.”
Shear Properties of Human Brain Tissue
Donnelly, B. R., & Medige, J. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2798289 · Cited by 237
A New Model Comparing Impact Responses of the Homogeneous and Inhomogeneous Human Brain
Zhou, C., Khalil, T. B., & King, A. I. (1995) · SAE Technical Paper Series · doi:10.4271/952714 · Cited by 201 · cited 3×
“Recall that isotropic regional differences were incorporated into a previous geometrically detailed FE model (Zhou et al., 1995).”
BackgroundInfluentialDirectional Dependence of Axonal Brain Injury due to Centroidal and Non-Centroidal Acceleration
Gennarelli, T. A., Thibault, L. E., Tomei, G., Wiser, R., Graham, D., & Adams, J. (1987) · SAE Technical Paper Series · doi:10.4271/872197 · Cited by 174 · cited 2×
“: 001 215 898 0882; fax: 001 215 573 2071; e-mail: margulie@seas.upenn.edu 1Current address: Children’s Hospital of Philadelphia, Philadelphia, PA, USA response to rotational inertial loads (Margulies et al., 1990), and is dependent on the load direction (Gennarelli et al., 1987).”
BackgroundTraumatic brain stem injury: MR imaging.
Gentry, L. R., Godersky, J. C., & Thompson, B. H. (1989) · Radiology · doi:10.1148/radiology.171.1.2928523 · Cited by 142 · cited 1×
“Damage to these regions are associated with high mortality because these sites serve as neural relay stations and as centers for vital functions (Gentry et al., 1989; Rosenblum et al., 1981).”
A high-frequency shear device for testing soft biological tissues
Arbogast, K. B., Thibault, K. L., Pinheiro, B. S., Winey, K. I., & Margulies, S. S. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00023-7 · Cited by 112 · cited 1×
“Mechanical properties of the porcine brainstem in shear were determined using a custom designed shear testing apparatus (STA) (Arbogast et al., 1997).”
Self-citationRosenblum, W. I., Greenberg, R. P., Seelig, J. M., & Becker, D. P. (1981) · Neurosurgery · doi:10.1227/00006123-198112000-00001 · Cited by 74 · cited 1×
“Damage to these regions are associated with high mortality because these sites serve as neural relay stations and as centers for vital functions (Gentry et al., 1989; Rosenblum et al., 1981).”
Cited by
Regional, Directional, and Age-Dependent Properties of the Brain Undergoing Large Deformation
Prange, M. T., & Margulies, S. S. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1449907 · Cited by 635
Self-citationViscoelastic properties of individual glial cells and neurons in the CNS
Lu, Y.-B., Franze, K., Seifert, G., Steinhäuser, C., Kirchhoff, F., Wolburg, H., Guck, J., Janmey, P., Wei, E.-Q., Käs, J., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606150103 · Cited by 578
Mechanical characterization of brain tissue in compression at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.01.022 · Cited by 426
Magnetic resonance elastography of the brain
Kruse, S. A., Rose, G. H., Glaser, K. J., Manduca, A., Felmlee, J. P., Jack, C. R., & Ehman, R. L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.030 · Cited by 424
Brain tissue deforms similarly to filled elastomers and follows consolidation theory
Franceschini, G., Bigoni, D., Regitnig, P., & Holzapfel, G. A. (2006) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2006.05.004 · Cited by 385
Fifty years of brain tissue mechanical testing: From in vitro to in vivo investigations
Chatelin, S., Constantinesco, A., & Willinger, R. (2010) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.3233/bir-2010-0576 · Cited by 342
Mechanical Heterogeneity of the Rat Hippocampus Measured by Atomic Force Microscope Indentation
Elkin, B. S., Azeloglu, E. U., Costa, K. D., & Morrison III, B. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2006.0169 · Cited by 316
Feng, Y., Okamoto, R. J., Namani, R., Genin, G. M., & Bayly, P. V. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.04.007 · Cited by 316
Mechanical properties of brain tissue by indentation: Interregional variation
van Dommelen, J. A. W., van der Sande, T. P. J., Hrapko, M., & Peters, G. W. M. (2010) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2009.09.001 · Cited by 283
Anisotropic constitutive equations and experimental tensile behavior of brain tissue
Velardi, F., Fraternali, F., & Angelillo, M. (2006) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-005-0007-9 · Cited by 258
Meaney, D. F., Morrison, B., & Dale Bass, C. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4026364 · Cited by 247
A comprehensive experimental study on material properties of human brain tissue
Jin, X., Zhu, F., Mao, H., Shen, M., & Yang, K. H. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.001 · Cited by 222
“The anisotropy of brain tissue, which could be associated with the highly oriented axon fibers, was reported in some studies (Arbogast and Margulies, 1998; Prange et al., 2000).”
ResultRheological properties of the tissues of the central nervous system: A review
Cheng, S., Clarke, E. C., & Bilston, L. E. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.003 · Cited by 212
The mechanical behaviour of brain tissue: Large strain response and constitutive modelling
Hrapko, M., van Dommelen, J. A. W., Peters, G. W. M., & Wismans, J. S. H. M. (2006) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2006043005004 · Cited by 208
“[26], and approximately 50 percent more compliant than data presented by Arbogast and Margulies [1] and Thibault and Margulies [30].”
InfluentialNonlinear viscoelastic effects in oscillatory shear deformation of brain tissue
Darvish, K. K., & Crandall, J. R. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00101-1 · Cited by 198
Six Degree-of-Freedom Measurements of Human Mild Traumatic Brain Injury
Hernandez, F., Wu, L. C., Yip, M. C., Laksari, K., Hoffman, A. R., Lopez, J. R., Grant, G. A., Kleiven, S., & Camarillo, D. B. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1212-4 · Cited by 197
Prevost, T. P., Balakrishnan, A., Suresh, S., & Socrate, S. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.06.035 · Cited by 197
“brainstem, cerebellum, thalamus, cerebral cortex, corpus callosum, associated with somewhat distinct mechanical properties [14–16].”
BackgroundMechanical characterization of brain tissue in simple shear at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.07.017 · Cited by 196
“Mostly dynamic oscillatory shear tests were conducted over a wide frequency range of 0.1 to 10000 Hz (Arbogast et al., 1995; Arbogast and Margulies, 1998; Arbogast et al., 1997; Bilston et al., 1997; Brands et al., 1999; 2000a; 2000b; 2004; Darvish and Crandall, 2001; Fallenstein et al., 1969; Garo…”
BackgroundMethodInfluentialNicolle, S., Lounis, M., & Willinger, R. (2004) · SAE Technical Paper Series · doi:10.4271/2004-22-0011 · Cited by 193
Ballistic helmets – Their design, materials, and performance against traumatic brain injury
Kulkarni, S. G., Gao, X.-L., Horner, S. E., Zheng, J. Q., & David, N. V. (2013) · Composite Structures · doi:10.1016/j.compstruct.2013.02.014 · Cited by 190
The Influence of Test Conditions on Characterization of the Mechanical Properties of Brain Tissue
Hrapko, M., van Dommelen, J. A. W., Peters, G. W. M., & Wismans, J. S. H. M. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2907746 · Cited by 184
Reactive glial cells: increased stiffness correlates with increased intermediate filament expression
Lu, Y., Iandiev, I., Hollborn, M., Körber, N., Ulbricht, E., Hirrlinger, P. G., Pannicke, T., Wei, E., Bringmann, A., Wolburg, H., et al. (2011) · The FASEB Journal · doi:10.1096/fj.10-163790 · Cited by 172
“Rheological studies of brainstem preparations have been carried out to understand posttraumatic mechanical alterations in CNS tissue (14).”
BackgroundViscoelastic characterization of in vitro canine tissue
Kiss, M. Z., Varghese, T., & Hall, T. J. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/18/002 · Cited by 172
Choo, A. M., Liu, J., Lam, C. K., Dvorak, M., Tetzlaff, W., & Oxland, T. R. (2007) · Journal of Neurosurgery: Spine · doi:10.3171/spi.2007.6.3.255 · Cited by 169
An axonal strain injury criterion for traumatic brain injury
Wright, R. M., & Ramesh, K. T. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0307-1 · Cited by 169
“Experimental studies, however, have shown that the material stiffness of the white matter is directionally dependent, especially at large strains ( Arbogast and Margulies 1998; Hrapko et al. 2008; Ning et al. 2006; Prange and Margulies 2002; van Dommelen et al. 2010).”
BackgroundQuasi-Static Ultrasound Elastography
Varghese, T. (2009) · Ultrasound Clinics · doi:10.1016/j.cult.2009.10.009 · Cited by 169
Immediate Damage to The Blood-Spinal Cord Barrier Due to Mechanical Trauma
Maikos, J. T., & Shreiber, D. I. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2006.0149 · Cited by 132
Metadata
- Authors
- Arbogast, K. B., & Margulies, S. S.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1998-09
- Volume
- 31
- Issue
- 9
- Pages
- 801-807
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2152099356
- Cited by
- 225
- References
- 11
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.