Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805 · cited 1×
“The following convention was used (Grood and Suntay, 1983).”
Cappozzo, A., Catani, F., Della Croce, U., & Leardini, A. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)91394-t · Cited by 1,677
Self-citationPosition and orientation in space of bones during movement: experimental artefacts
Cappozzo, A., Catani, F., Leardini, A., Benedetti, M., & Della Croce, U. (1996) · Clinical Biomechanics · doi:10.1016/0268-0033(95)00046-1 · Cited by 756 · cited 2×
“The artefacts affecting a BTF during movement, mostly originate from the rotations of the adjacent joints and are strongly correlated with them (Cappozzo et al., 1996).”
BackgroundSelf-citationDetermining the movements of the skeleton using well-configured markers
Söderkvist, I., & Wedin, P.-Å. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90098-y · Cited by 735
Three-dimensional kinematics of the human knee during walking
Lafortune, M. A., Cavanagh, P. R., Sommer, H. J., & Kalenak, A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90254-x · Cited by 694
Rigid body motion calculated from spatial co-ordinates of markers
Spoor, C. W., & Veldpaus, F. E. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90020-2 · Cited by 579
Surface-marker cluster design criteria for 3-D bone movement reconstruction
Cappozzo, A., Cappello, A., Croce, U. D., & Pensalfini, F. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.649988 · Cited by 456 · cited 3×
“For each bony segment, the BTF position vector and orientation matrix were estimated using the position vectors of the cluster markers in the LF and an unweighted least-squares operator which makes use of the singular value decomposition algorithm (Cappozzo et al., 1997).”
BackgroundMethodSelf-citationA least-squares algorithm for the equiform transformation from spatial marker co-ordinates
Veldpaus, F. E., Woltring, H. J., & Dortmans, L. J. M. G. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90190-x · Cited by 422
A procedure for determining rigid body transformation parameters
Challis, J. H. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00116-l · Cited by 398 · cited 1×
“Residual photogrammetric errors and skin movement artefact components, which cause cluster deformation, are dealt with using rigid body pose optimal estimators (Spoor and Veldpaus, 1980; Veldpaus et al., 1988; Söderkvist and Wedin, 1993; Challis, 1994; Challis, 1995; Cheze et al., 1995; Cappozzo et al., 1997).”
BackgroundCappozzo, A. (1984) · Human Movement Science · doi:10.1016/0167-9457(84)90004-6 · Cited by 361 · cited 3×
“The centre of the acetabulum (AC) was estimated in the pelvis BAF as the mean centre of rotation of the femur relative to the pelvis (functional approach; Cappozzo, 1984; Cappozzo et al., 1995b).”
MethodResultSelf-citationA solidification procedure to facilitate kinematic analyses based on video system data
Chèze, L., Fregly, B. J., & Dimnet, J. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)95278-d · Cited by 222 · cited 1×
“Residual photogrammetric errors and skin movement artefact components, which cause cluster deformation, are dealt with using rigid body pose optimal estimators (Spoor and Veldpaus, 1980; Veldpaus et al., 1988; Söderkvist and Wedin, 1993; Challis, 1994; Challis, 1995; Cheze et al., 1995; Cappozzo et al., 1997).”
BackgroundMultiple anatomical landmark calibration for optimal bone pose estimation
Cappello, A., Cappozzo, A., La Palombara, P. F., Lucchetti, L., & Leardini, A. (1997) · Human Movement Science · doi:10.1016/s0167-9457(96)00055-3 · Cited by 161 · cited 1×
“Vectors w are usually assumed to be time invariant and determined through an ad hoc experiment referred to as ‘anatomical landmark calibration’ (Cappozzo, 1984; Cappozzo et al., 1995a; Cappello et al., 1997).”
MethodSelf-citationPennock, G. R., & Clark, K. J. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90378-g · Cited by 114 · cited 1×
“in Pennock and Clark (1990), is irrelevant in the present context.”
BackgroundChallis, J. H. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)91877-j · Cited by 38
Assessment and testing of movement analysis systems: spot checks
Cappozzo, A., Croce, U. D., Fioretti, S., Leardini, A., Leo, T., & Maurizi, M. (1995) · Gait & Posture · doi:10.1016/0966-6362(95)99075-v · Cited by 6 · cited 1×
“A spot check on the system (Cappozzo et al., 1994) gave an average precision of 1.”
BackgroundSelf-citation
Cited by
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Self-citationDynamic Measurements of Three-Dimensional Scapular Kinematics: A Validation Study
Karduna, A. R., McClure, P. W., Michener, L. A., & Sennett, B. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1351892 · Cited by 622
Repeatability of gait data using a functional hip joint centre and a mean helical knee axis
Besier, T. F., Sturnieks, D. L., Alderson, J. A., & Lloyd, D. G. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00087-3 · Cited by 532
Mündermann, L., Corazza, S., & Andriacchi, T. P. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-6 · Cited by 387
Quantification of soft tissue artifact in lower limb human motion analysis: A systematic review
Peters, A., Galna, B., Sangeux, M., Morris, M., & Baker, R. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.09.004 · Cited by 367
Metadata
- Authors
- Lucchetti, L., Cappozzo, A., Cappello, A., & Croce, U. D.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1998-11
- Volume
- 31
- Issue
- 11
- Pages
- 977-984
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1984033828
- Cited by
- 211
- References
- 15
- FWCI
- 3.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.