Accuracy of cancellous bone volume fraction measured by micro-CT scanning
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071 · cited 2×
“, 1990) or on using stereological techniques on histological sections (Kelvin, 1969). As a non-invasive method, microtomography for 3-D reconstruction of cancellous bone has attracted much interest. The bone volume fraction can easily be calculated from voxel based 3-D reconstructions of micro-CT images (Kuhn et al.,…”
BackgroundA microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
Self-citationQuantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions
Odgaard, A., & Gundersen, H. J. G. (1993) · Bone · doi:10.1016/8756-3282(93)90245-6 · Cited by 680 · cited 1×
“Furthermore, the connectivity densities of these 20 specimens were determined (Odgaard and Gundersen, 1993).”
BackgroundSelf-citationEvaluation of a microcomputed tomography system to study trabecular bone structure
Kuhn, J. L., Goldstein, S. A., Feldkamp, L. A., Goulet, R. W., & Jesion, G. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080608 · Cited by 336 · cited 1×
“The bone volume fraction can easily be calculated from voxel based 3-D reconstructions of micro-CT images (Kuhn et al., 1990; Rüegsegger et al., 1996; Odgaard, 1997).”
BackgroundAge variations in the properties of human tibial travecular bone
Ding, M. L., Dalstra, M., Danielsen, C. C., Kabel, J., Hvid, I., & Linde, F. (1997) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.79b6.7538 · Cited by 181
Self-citationMüller, R., Koller, B. J., Hildebrand, T., Laib, A., Gianolini, S., & Ruegsegger, P. (1996) · Technology and Health Care · doi:10.3233/thc-1996-4112 · Cited by 175
White, K. L., Murnaghan, J. H., & Gaus, C. R. (1972) · New England Journal of Medicine · doi:10.1056/nejm197212142872404 · Cited by 158
Measurement of the density of trabecular bone
Sharp, D. J., Tanner, K. E., & Bonfield, W. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90032-x · Cited by 55 · cited 2×
“Traditionally, volume fraction measurements have been based on Archimedes’ principle (Sharp et al., 1990) or on using stereological techniques on histological sections (Kelvin, 1969).”
Method
Cited by
Day, J. S., Ding, M., van der Linden, J. C., Hvid, I., Sumner, D. R., & Weinans, H. (2001) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00012-2 · Cited by 245
Self-citationDing, M., & Hvid, I. (2000) · Bone · doi:10.1016/s8756-3282(99)00281-1 · Cited by 231
Self-citationMicro-CT of rodents: State-of-the-art and future perspectives
Clark, D. P., & Badea, C. T. (2014) · Physica Medica · doi:10.1016/j.ejmp.2014.05.011 · Cited by 229
“In all cases, care must be taken in the selection of the threshold value, as it has a significant impact on the results [103].”
BackgroundAn Improved Segmentation Method for In Vivo μCT Imaging
Waarsing, J. H., Day, J. S., & Weinans, H. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040705 · Cited by 212
“The third set was obtained by setting the global threshold at a value where the sensitivity of the volume to changes in threshold value was smallest, as determined after analysis of the density histogram((15)) (GlobalHist).”
MethodInfluentialAge‐related variations in the microstructure of human tibial cancellous bone
Ding, M., Odgaard, A., Linde, F., & Hvid, I. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00132-2 · Cited by 186
Self-citation
Metadata
- Authors
- Ding, M., Odgaard, A., & Hvid, I.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1999-03
- Volume
- 32
- Issue
- 3
- Pages
- 323-326
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1976390487
- Cited by
- 213
- References
- 9
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.