Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 277

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Sensitive detection of oxidatively modified low density lipoprotein using a monoclonal antibody.

Open access
Itabe, H, Yamamoto, H, Imanaka, T, Shimamura, K, Uchiyama, H, Kimura, J, Sanaka, T, Hata, Y, Takano, T · 1996 · Journal of Lipid Research

Abstract

We have established a new method capable of measuring the very low concentrations of oxidized low density lipoprotein (OxLDL). In our previous study, we obtained a novel murine monoclonal antibody against oxidized lipoproteins (Itabe, H. et al. 1994. J. Biol. Chem. 269: 15274-15279). The epitope of this antibody resides in oxidized products of phosphatidylcholine that can form complexes with polypeptides, including apolipoprotein B. When the monoclonal antibody was precoated onto microtiter wells prior to carrying out a sandwich ELISA using an anti-human apolipoprotein B antibody, it was possible to detect 0.5 ng protein of copper-induced OxLDL. The detection of OxLDL was dependent on the presence of monoclonal antibody and was blocked by oxidized phosphatidylcholine (OxPC). Under the same sandwich ELISA condition, native LDL showed a dose-dependent increase of absorbance that was inhibited by complex of OxPC with BSA. These results suggest the possible occurrence of oxidative modification of human plasma LDL, which is recognized by the antibody against OxPC. The level of LDL oxidation of normal human subjects was found to be 0.52 +/- 0.35 units per 5 mu g protein of LDL, where one unit was defined as the reactivity corresponding to 1 ng of copper-induced OxLDL by this assay. Furthermore, we found that the LDL oxidation level in patients who had been receiving hemodialysis treatment was increased more than eightfold over that of normal subjects. We suggest that LDL in human plasma is oxidatively modified under certain conditions and this method for measurement of OxLDL could be used to study the relationship between in vivo oxidation reaction and various pathological conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-2275(20)37634-3

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 277

Metadata

Authors
Itabe, H., Yamamoto, H., Imanaka, T., Shimamura, K., Uchiyama, H., Kimura, J., Sanaka, T., Hata, Y., & Takano, T.
Venue
Journal of Lipid Research
Publisher
Elsevier BV
Published
1996-01
Volume
37
Issue
1
Pages
45-53
ISSN
0022-2275 (ISSN-L)
OpenAlex
W2144302240
Cited by
277
References
34
FWCI
3.71
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitive detection of oxidatively modified low density lipoprotein using a monoclonal antibody. https://app.cochat.ai/papers/10.1016/s0022-2275(20)37634-3
The paper
Itabe, H., Yamamoto, H., Imanaka, T., Shimamura, K., Uchiyama, H., Kimura, J., Sanaka, T., Hata, Y., & Takano, T. (1996). Sensitive detection of oxidatively modified low density lipoprotein using a monoclonal antibody. Journal of Lipid Research. https://doi.org/10.1016/s0022-2275(20)37634-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.