Characterization of biological cells by dielectric spectroscopy
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Treatise on Electricity and Magnetism
(1873) · Nature · doi:10.1038/007478a0 · Cited by 4,537
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786
A Treatise on Electricity and Magnetism
Maxwell, J. C. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511709340 · Cited by 2,457
Erklärung der dielektrischen Nachwirkungsvorgänge auf Grund Maxwellscher Vorstellungen
Wagner, K. W. (1914) · Archiv für Elektrotechnik · doi:10.1007/bf01657322 · Cited by 1,137
Cole, K. S. (1968) · University of California Press eBooks · doi:10.1525/9780520326514 · Cited by 992
CRC Handbook of Biological Effects of Electromagnetic Fields
Polk, C. (2019) · CRC Press eBooks · doi:10.1201/9781351071017 · Cited by 936
Schwarz, G. (1962) · The Journal of Physical Chemistry · doi:10.1021/j100818a067 · Cited by 861
Pethig, R., & Kell, D. B. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/8/001 · Cited by 796
Handbook of biological effects of electromagnetic fields
(1996) · Choice Reviews Online · doi:10.5860/choice.33-6361 · Cited by 696
Hanai, T. (1960) · Kolloid-Zeitschrift · doi:10.1007/bf01520320 · Cited by 512
Cited by
A review of impedance measurements of whole cells
Xu, Y., Xie, X., Duan, Y., Wang, L., Cheng, Z., & Cheng, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.027 · Cited by 424
Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations
Gawad, S., Cheung, K., Seger, U., Bertsch, A., & Renaud, P. (2004) · Lab on a Chip · doi:10.1039/b313761a · Cited by 323
Tseng, P., Napier, B., Garbarini, L., Kaplan, D. L., & Omenetto, F. G. (2018) · Advanced Materials · doi:10.1002/adma.201703257 · Cited by 221
Heileman, K., Daoud, J., & Tabrizian, M. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.04.017 · Cited by 202
Advances in on-line monitoring and control of mammalian cell cultures: Supporting the PAT initiative
Teixeira, A. P., Oliveira, R., Alves, P. M., & Carrondo, M. J. T. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.05.003 · Cited by 193
“The application of an electric field to the culture bulk results in movement of ions in the medium and within the cells, leading to charge separation or polarization across the plasma membrane (Asami, 2002).”
BackgroundBooth, J. C., Orloff, N. D., Mateu, J., Janezic, M., Rinehart, M., & Beall, J. A. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2047141 · Cited by 172
“suspensions [ 6 ], [7], and proteins [8], and has been applied to monitor cell cultures [9].”
BackgroundBroadband dielectric spectroscopy on human blood
Wolf, M., Gulich, R., Lunkenheimer, P., & Loidl, A. (2011) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2011.05.012 · Cited by 161
“neglected). However, the found relaxation-time ratio of the order of 10 is too high to be explainable by this model, at least if assuming a reasonable ratio of the two semi-diameters of the spheroids [61, 120]. The spectra on rabbit erythrocytes, mentioned above, also could not be described by the Maxwell-Wagner model…”
Background
Metadata
- Authors
- Asami, K.
- Venue
- Journal of Non-Crystalline Solids
- Publisher
- Elsevier BV
- Published
- 2002-07
- Volume
- 305
- Issue
- 1-3
- Pages
- 268-277
- ISSN
- 0022-3093 (ISSN-L)
- OpenAlex
- W2065993237
- Cited by
- 252
- References
- 30
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.