Pulse oximetry in pediatric intensive care: Comparison with measured saturations and transcutaneous oxygen tension
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
YELDERMAN, M., & NEW, W. (1983) · Anesthesiology · doi:10.1097/00000542-198310000-00015 · Cited by 486
Spectrophotometric monitoring of arterial oxygen saturation in the fingertip
Yoshiya, I., Shimada, Y., & Tanaka, K. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442476 · Cited by 261
Transcutaneous oxygen monitoring of critically ill adults, with and without low flow shock
TREMPER, K. K., & SHOEMAKER, W. C. (1981) · Critical Care Medicine · doi:10.1097/00003246-198110000-00007 · Cited by 243
Oxygen Toxicity in Man: A Prospective Study in Patients with Irreversible Brain Damage
BARBER, R. E., Lee, J., & Hamilton, W. K. (1970) · New England Journal of Medicine · doi:10.1056/nejm197012312832702 · Cited by 155
The Accuracy and Response Characteristics of a Simplified Ear Oximeter
Rebuck, A. S., Chapman, K. R., & D’Urzo, A. D. (1983) · CHEST Journal · doi:10.1378/chest.83.6.860 · Cited by 126
Oxygen Toxicity in Man: A Prospective Study in Patients after Open-Heart Surgery
Singer, M. M., Wright, F. E., Stanley, L. K., Roe, B. B., & Hamilton, W. K. (1970) · New England Journal of Medicine · doi:10.1056/nejm197012312832701 · Cited by 121
Clinical evaluation of a new ear oximeter.
Scoggin, C., Nett, L. M., & Tl, P. (1977) · PubMed · Cited by 39
CONTINUOUS NON-INVASIVE OXYGEN SATURATION MONITORING IN CHILDREN WITH A NEW PULSE-OXIMETER
Swedlow, D. B., & Stern, S. (1983) · Critical Care Medicine · doi:10.1097/00003246-198303000-00060 · Cited by 22
Cited by
Kelleher, J. F. (1989) · Journal of Clinical Monitoring · doi:10.1007/bf01618369 · Cited by 202
Outpatient Assessment of Infants With Bronchiolitis
Shaw, K. N. (1991) · Archives of Pediatrics & Adolescent Medicine · doi:10.1001/archpedi.1991.02160020041012 · Cited by 169
GABRIELCZYK, M. R., & BUIST, R. J. (1988) · Anaesthesia · doi:10.1111/j.1365-2044.1988.tb09025.x · Cited by 59
Pulse oximetry in sickle cell anemia
Fitzgerald, R. K., & Johnson, A. (2001) · Critical Care Medicine · doi:10.1097/00003246-200109000-00025 · Cited by 55
A clinical evaluation of the accuracy of the Nellcor N-100 and Ohmeda 3700 pulse oximeters
Cecil, W. T., Thorpe, K. J., Fibuch, E. E., & Tuohy, G. F. (1988) · Journal of Clinical Monitoring · doi:10.1007/bf01618105 · Cited by 51
“Fanconi et al [2], in a study o f critically ill pediatric patients, compared Nellcor N-100 oximeter 8pO2 with blood HbO2 and reported a linear regression o f y = 0.”
Background
Metadata
- Authors
- Fanconi, S., Doherty, P., Edmonds, J. F., Barker, G. A., & Bohn, D. J.
- Venue
- The Journal of Pediatrics
- Publisher
- Elsevier BV
- Published
- 1985-09
- Volume
- 107
- Issue
- 3
- Pages
- 362-366
- ISSN
- 0022-3476 (ISSN-L)
- OpenAlex
- W1999397242
- Cited by
- 159
- References
- 8
- FWCI
- 23.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.