Cited by 59Non-Invasive Vital Sign MonitoringHemodynamic Monitoring and TherapyThermal Regulation in Medicine

Pulse oximetry and postoperative hypothermia: An evaluation of the Nellcor N‐100 in a cardiac surgical intensive care unit

Open access
GABRIELCZYK, M. R., BUIST, R. J.·1988·Anaesthesia

Abstract

The accuracy of the Nellcor N-100 pulse oximeter was evaluated in hypothermic patients (core temperature less than or equal to 35.0 degrees C) after cardiac surgery. The pulse oximeter overestimated oxygen saturation in comparison to values obtained by direct in vitro oximetry with a mean bias of 0.6% saturation. The 95% predictability limits for individual measurements were +/- 3.9% oxygen saturation. No demonstrable loss of accuracy was caused by skin pigmentation, the concurrent administration of low doses of dopamine or vasodilators, or the intra-operative intravascular administration of Patent Blue V dye.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2044.1988.tb09025.x

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 3

  1. HANNIX CD. Monitoring oxygcnation during anaesthesia. Britis/i Journul of .4nur.sfhr.riu 1985; 57: 359
  2. MIHM FG. HALPERIN BD. Noninvasive dctcction o f profound a]-terial desaturations using a pulsc oxinicti-y device. .Anc..sfhc..vi- ologj' 1985; 62: 85
  3. FANCONI S, DOHERTY P. EDMONDS JF. BARKER G A , BOHY 13652044, 1988, 5, Downloaded from https://associationofanaesthetists-publications.onlinelibrary.wiley.com/doi/10.1111/j.1365-2044.1988.tb09025.x by Mount Vernon Nazarene University, Wiley Online Library on [23/06/2026]. See the Terms and Conditions (https://onlinelibrary.wiley.com/terms-and-conditions) on Wiley Online Library for rules of use; OA articles are governed by the applicable Creative Commons License · DOI

Cited by

Sorted by citations

Authors
GABRIELCZYK, M. R., & BUIST, R. J.
Affiliations
University College Hospital at Westmoreland Street (GB)
Venue
Anaesthesia
Publisher
Wiley
Published
1988-05
Volume
43
Issue
5
Pages
402-404
ISSN
  • 0003-2409 (ISSN-L)
  • 1365-2044
OpenAlex
W1876894315
Cited by
59
References
11
Citations by year
2026: 1 · 2024: 2 · 2023: 1 · 2022: 23
FWCI
4.82
Type
journal article
Language
en
Open access
Locations
  • Anaesthesia (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
Keywords
pulse oximetry, postoperative hypothermia, oxygen saturation measurement, cardiac surgery, measurement accuracy, skin pigmentation, dopamine, vasodilators, Patent Blue V, core body temperature
MeSH terms
Aged, Critical Care, Evaluation Studies as Topic, Cardiac Surgical Procedures, Humans, Hypothermia, Middle Aged, Oximetry, Oxygen, Postoperative Complications

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review