Blockade of Opioid Receptors in Rostral Ventral Medulla Prevents Antihyperalgesia Produced by Transcutaneous Electrical Nerve Stimulation (TENS)
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Although transcutaneous electrical nerve stimulation (TENS) is used extensively in inflammatory joint conditions such as arthritis, the underlying mechanisms are unclear. This study aims to demonstrate an opiate-mediated activation of descending inhibitory pathways from the rostral ventral medulla (RVM) in the antihyperalgesia produced by low- (4 Hz) or high-frequency (100 Hz) TENS. Paw withdrawal latency to radiant heat, as an index of secondary hyperalgesia, was recorded before and after knee joint inflammation (induced by intra-articular injection of 3% kaolin and carrageenan) and after TENS/no TENS coadministered with naloxone (20 microg/1 microl), naltrindole (5 microg/1 microl), or vehicle (1 microl) microinjected into the RVM. The selectivity of naloxone and naltrindole doses was tested against the mu-opioid receptor agonist [D-Ala2,N-Me-Phe4,Gly-ol5]-enkephalin (DAMGO) (20 ng, 1 microl) and the delta2-opioid receptor agonist deltorphin (5 microg, 1 microl) in the RVM. Naloxone microinjection into the RVM blocks the antihyperalgesia produced by low frequency (p < 0.001), but not that produced by high-frequency TENS (p > 0.05). In contrast, naltrindole injection into the RVM blocks the antihyperalgesia produced by high-frequency (p < 0.05), but not low-frequency (p > 0.05) TENS. The analgesia produced by DAMGO and deltorphin is selectively blocked by naloxone (p < 0.05) and naltrindole (p < 0.05), respectively. Thus, the dose of naloxone and naltrindole used in the current study blocks mu- and delta-opioid receptors, respectively. Hence, low-frequency and high-frequency TENS produces antihyperalgesia by activation of mu- and delta-opioid receptors, respectively, in the RVM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Rat Brain in Stereotaxic Coordinates
(1982) · Elsevier eBooks · doi:10.1016/c2009-0-63235-9 · Cited by 51,963
Melzack, R., & Wall, P. D. (1965) · Science · doi:10.1126/science.150.3699.971 · Cited by 11,090
A new and sensitive method for measuring thermal nociception in cutaneous hyperalgesia
Hargreaves, K., Dubner, R., Brown, F., Flores, C., & Joris, J. (1988) · Pain · doi:10.1016/0304-3959(88)90026-7 · Cited by 5,135
Han, J. S., Chen, X. H., Sun, S. L., Xu, X. J., Yuan, Y., Yan, S. C., Hao, J. X., & Terenius, L. (1991) · Pain · doi:10.1016/0304-3959(91)90218-m · Cited by 448
The influence of naloxone on analgesia produced by peripheral conditioning stimulation
Sjölund, B. H., & Eriksson, M. B. E. (1979) · Brain Research · doi:10.1016/0006-8993(79)90629-2 · Cited by 328
Spinal Blockade of Opioid Receptors Prevents the Analgesia Produced by TENS in Arthritic Rats
Sluka, K. A., Deacon, M., Stibal, A., Strissel, S., & Terpstra, A. (1999) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(24)38209-6 · Cited by 320
Self-citationArvidsson, U., Dado, R., Riedl, M., Lee, J., Law, P., Loh, H., Elde, R., & Wessendorf, M. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-02-01215.1995 · Cited by 280
Dickenson, A. H., Oliveras, J.-L., & Besson, J.-M. (1979) · Brain Research · doi:10.1016/0006-8993(79)90943-0 · Cited by 258
Wang, B., Tang, J., White, P. F., Naruse, R., Sloninsky, A., Kariger, R., Gold, J., & Wender, R. H. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199708000-00029 · Cited by 216
Kovelowski, C. J., Ossipov, M. H., Sun, H., Lai, J., Malan, T. P., & Porreca, F. (2000) · Pain · doi:10.1016/s0304-3959(00)00290-6 · Cited by 211
Cited by
Transcutaneous electrical nerve stimulation: Basic science mechanisms and clinical effectiveness
Sluka, K. A., & Walsh, D. (2003) · The Journal of Pain · doi:10.1054/jpai.2003.434 · Cited by 809
Self-citationUsing Tens for Pain Control: The State of the Evidence
Vance, C. G., Dailey, D. L., Rakel, B. A., & Sluka, K. A. (2014) · Pain Management · doi:10.2217/pmt.14.13 · Cited by 480
Self-citationEffectiveness of transcutaneous electrical nerve stimulation for treatment of hyperalgesia and pain
DeSantana, J. M., Walsh, D. M., Vance, C., Rakel, B. A., & Sluka, K. A. (2008) · Current Rheumatology Reports · doi:10.1007/s11926-008-0080-z · Cited by 419
Self-citationTranscutaneous electrical nerve stimulation (TENS) versus placebo for chronic low-back pain
Khadilkar, A., Odebiyi, D. O., Brosseau, L., & Wells, G. A. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003008.pub3 · Cited by 304
A Mechanism-Based Approach to Physical Therapist Management of Pain
Chimenti, R. L., Frey-Law, L. A., & Sluka, K. A. (2018) · Physical Therapy · doi:10.1093/ptj/pzy030 · Cited by 300
Self-citationTranscutaneous electrical nerve stimulation for acute pain
Walsh, D. M., Howe, T. E., Johnson, M. I., Moran, F., & Sluka, K. A. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006142.pub2 · Cited by 247
Self-citationTranscutaneous electrical nerve stimulation (TENS) for neuropathic pain in adults
Gibson, W., Wand, B. M., & O'Connell, N. E. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011976.pub2 · Cited by 247
Dailey, D. L., Rakel, B. A., Vance, C. G. T., Liebano, R. E., Amrit, A. S., Bush, H. M., Lee, K. S., Lee, J. E., & Sluka, K. A. (2013) · Pain · doi:10.1016/j.pain.2013.07.043 · Cited by 241
“Basic science studies show that TENS reduces enhanced excitability of neurons in the pain pathways [17,18,23,31,55] and activates pain inhibitory mechanisms to reduce hyperalgesia [9,23,53].”
BackgroundSelf-citationSluka, K. A., Bjordal, J. M., Marchand, S., & Rakel, B. A. (2013) · Physical Therapy · doi:10.2522/ptj.20120281 · Cited by 204
Self-citationMoran, F., Leonard, T., Hawthorne, S., Hughes, C. M., McCrum-Gardner, E., Johnson, M. I., Rakel, B. A., Sluka, K. A., & Walsh, D. M. (2011) · The Journal of Pain · doi:10.1016/j.jpain.2011.02.352 · Cited by 201
Self-citationNijs, J., Meeus, M., Van Oosterwijck, J., Ickmans, K., Moorkens, G., Hans, G., & De Clerck, L. S. (2012) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.2011.02575.x · Cited by 192
Release of GABA and activation of GABAA in the spinal cord mediates the effects of TENS in rats
Maeda, Y., Lisi, T. L., Vance, C. G. T., & Sluka, K. A. (2007) · Brain Research · doi:10.1016/j.brainres.2006.11.061 · Cited by 184
“N IH -PA Author M anuscript N IH -PA Author M anuscript opioid receptors suprapspinally (Sluka et al., 1999; Kalra et al., 2001; Radhakrishnan and Sluka, 2003; Radhakrishnan et al., 2003).”
BackgroundSelf-citationVance, C. G. T., Rakel, B. A., Blodgett, N. P., DeSantana, J. M., Amendola, A., Zimmerman, M. B., Walsh, D. M., & Sluka, K. A. (2012) · Physical Therapy · doi:10.2522/ptj.20110183 · Cited by 178
Self-citationLao, L., Zhang, R.-X., Zhang, G., Wang, X., Berman, B. M., & Ren, K. (2004) · Brain Research · doi:10.1016/j.brainres.2004.01.092 · Cited by 167
“Blockage of opioid receptors in RVM prevents TENS-produced antihyperalgesai [28].”
DeSantana, J. M., Da Silva, L. F. S., De Resende, M. A., & Sluka, K. A. (2009) · Neuroscience · doi:10.1016/j.neuroscience.2009.06.056 · Cited by 159
“Specifically, low (4 Hz) frequency TENS activates μ-opioid receptors and high (100 Hz) frequency TENS activates δ-opioid receptors (Sluka et al., 1999; Kalra et al., 2001).”
InfluentialSelf-citationSchabrun, S. M., Jones, E., Elgueta Cancino, E. L., & Hodges, P. W. (2014) · Brain Stimulation · doi:10.1016/j.brs.2014.01.058 · Cited by 159
“PES targets mechanisms of sensitization such as activation of descending antinociceptive pathways [11,12], activation of inhibitory neural circuits in the spinal cord [13], enhanced opioid and inhibitory neurotransmitter receptor activity [14,15] and consequently, spinal upregulation of inhibitory neurotransmitter rel…”
BackgroundReview of recent advances in peripheral nerve stimulation (PNS)
Chakravarthy, K., Nava, A., Christo, P. J., & Williams, K. (2016) · Current Pain and Headache Reports · doi:10.1007/s11916-016-0590-8 · Cited by 136
Rakel, B. A., Zimmerman, B. M., Geasland, K., Embree, J., Clark, C. R., Noiseux, N. O., Callaghan, J. J., Herr, K., Walsh, D., & Sluka, K. A. (2014) · Pain · doi:10.1016/j.pain.2014.09.025 · Cited by 115
“TENS activates endogenous inhibitory mechanisms including opioid receptors in the spinal cord and brainstem [22,41,65], reduces central neuron sensitization [47], and reduces primary and secondary mechanical hyperalgesia (ie, pain sensitivity to force or pressure) induced by knee joint inflammation [56,61,64,72].”
BackgroundSelf-citation
Metadata
- Authors
- Kalra, A., Urban, M. O., & Sluka, K. A.
- Venue
- The Journal of Pharmacology and Experimental Therapeutics
- Publisher
- Elsevier BV
- Published
- 2001-07
- Volume
- 298
- Issue
- 1
- Pages
- 257-263
- ISSN
- 0022-3565 (ISSN-L)
- OpenAlex
- W2100922294
- Cited by
- 341
- References
- 37
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.