The DOI matches its Crossref record.
The “first generation” of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta
Open accessAbstract
OBJECTIVE: Our goal was to determine whether endovascular stent-grafting is feasible and effective for patients with aneurysms of the descending thoracic aorta. METHODS: Starting in July 1992, we conducted a prospective, uncontrolled clinical trial in 103 patients (mean age 69 years [range 34-89 years]) who underwent endovascular treatment of aneurysms of the descending thoracic aorta using a custom-fabricated, self-expanding stent-graft device. Follow-up was 100% complete and averaged 22 months. Sixty-two patients (60%) were judged not to be reasonable candidates for a conventional "open" surgical procedure. RESULTS: Complete thrombosis of the aneurysm was ultimately achieved in 86 (83%) patients. The early mortality rate was 9% +/- 3% (+/- 70% CL). Multivariable analysis revealed that myocardial infarction or stroke was linked with a higher likelihood of early death (P = .001). Early serious complications included paraplegia in 3% +/- 2% and stroke in 7% +/- 3%. Actuarial survival estimates at 1 year and 2 years were 81% +/- 4% and 73% +/- 5% (+/- 1 SE), respectively; being judged not to be a surgical candidate portended a higher probability of death (P = .003). According to the intent-to-treat principle, "treatment failure" (including all late sudden unexplained deaths) occurred in 38 patients; 53% +/- 10% of patients were free from treatment failure at 3.7 years. Stent-graft related complications occurred commonly and were linked with several anatomic, technical, and patient-related risk factors. CONCLUSIONS: This 5-year clinical trial involving use of a "first generation" device indicates that endovascular stent-grafting of descending thoracic aortic aneurysms is feasible with acceptable medium-term results. More refined, commercially developed devices available today offer less traumatic and more precise stent-graft deployment; these major technical advantages, coupled with important lessons we have learned over time and better patient selection, should be associated with more salutary clinical results in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Buth, J., Harris, P. L., Hobo, R., van Eps, R., Cuypers, P., Duijm, L., & Tielbeek, X. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2007.08.020 · Cited by 622
Daye, D., & Walker, T. G. (2018) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2017.09.17 · Cited by 266
Transcatheter Heart Valves: A Biomaterials Perspective
Bui, H. T., Khair, N., Yeats, B., Gooden, S., James, S. P., & Dasi, L. P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100115 · Cited by 36
Metadata
- Authors
- Dake, M. D., Miller, D. C., Mitchell, R. S., Semba, C. P., Moore, K. A., & Sakai, T.
- Venue
- The Journal of Thoracic and Cardiovascular Surgery
- Publisher
- Elsevier BV
- Published
- 1998-11
- Volume
- 116
- Issue
- 5
- Pages
- 689-704
- ISSN
- 0022-5223 (ISSN-L)
- OpenAlex
- W2044205516
- Cited by
- 453
- References
- 0
- FWCI
- 20.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The “first generation” of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta. https://app.cochat.ai/papers/10.1016/s0022-5223(98)00455-3
- The paper
- Dake, M. D., Miller, D. C., Mitchell, R. S., Semba, C. P., Moore, K. A., & Sakai, T. (1998). The “first generation” of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/s0022-5223(98)00455-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.