IS EVERYTHING ALL RIGHT IF NOTHING SEEMS WRONG? A SIMPLE METHOD OF ASSESSING THE DIAGNOSTIC VALUE OF ENDOSCOPIC PROCEDURES WHEN A GOLD STANDARD IS ABSENT
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: We demonstrate a simple yet comprehensive method to evaluate the sensitivity of endoscopic procedures when no gold standard is available. MATERIALS AND METHODS: In 208 consecutive patients with superficial bladder cancer 328 endoscopies were performed to compare the sensitivity of white light and 5-aminolevulinic acid induced fluorescence endoscopy. Both procedures were performed during the same session. RESULTS: The maximum interval of observable sensitivity for 5-aminolevulinic acid induced fluorescence endoscopy ranged between 78 and 97.5%, and the best estimate for sensitivity based on realistic assumptions was 93.4% (95% confidence intervals 90 to 97.3). The best sensitivity estimate for white light endoscopy was 46.7% (95% confidence intervals 39.4 to 54.3, maximum range 47.2 to 53%). CONCLUSIONS: This method to determine the maximum possible range of sensitivity estimates for endoscopic procedures without a gold standard is easily applied. Depending on the assumptions a range of reasonable scenarios can be constructed and the corresponding sensitivities can be reported. This approach gives fast and valid results, and could further indicate the diagnostic superiority of 5-aminolevulinic acid induced fluorescence compared to white light endoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kriegmair, M., Ehsan, A., Baumgartner, R., Lumper, W., Knuechel, R., Hofstädter, F., Steinbach, P., & Hofstetter, A. (1994) · Urology · doi:10.1016/s0090-4295(94)80167-3 · Cited by 265
Self-citation
Cited by
Evaluation of diagnostic tests when there is no gold standard. A review of methods
Rutjes, A., Reitsma, J., Coomarasamy, A., Khan, K., & Bossuyt, P. (2007) · Health Technology Assessment · doi:10.3310/hta11500 · Cited by 524
Reitsma, J. B., Rutjes, A. W. S., Khan, K. S., Coomarasamy, A., & Bossuyt, P. M. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.02.005 · Cited by 405
Detection of Bladder Cancer Using a Point-of-Care Proteomic Assay
Grossman, H. B. (2005) · JAMA · doi:10.1001/jama.293.7.810 · Cited by 367
Mowatt, G., Zhu, S., Kilonzo, M., Boachie, C., Fraser, C., Griffiths, T., N'Dow, J., Nabi, G., Cook, J., & Vale, L. (2010) · Health Technology Assessment · doi:10.3310/hta14040 · Cited by 313
Surveillance for Recurrent Bladder Cancer Using a Point-of-Care Proteomic Assay
Grossman, H. B. (2006) · JAMA · doi:10.1001/jama.295.3.299 · Cited by 265
Quantitation of Promoter Methylation of Multiple Genes in Urine DNA and Bladder Cancer Detection
Hoque, M. O., Begum, S., Topaloglu, O., Chatterjee, A., Rosenbaum, E., Van Criekinge, W., Westra, W. H., Schoenberg, M., Zahurak, M., Goodman, S. N., et al. (2006) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djj265 · Cited by 262
5‐Aminolevulinic Acid Derivatives in Photomedicine: Characteristics, Application and Perspectives
Fotinos, N., Campo, M. A., Popowycz, F., Gurny, R., & Lange, N. (2006) · Photochemistry and Photobiology · doi:10.1562/2006-02-03-ir-794 · Cited by 238
“The general sensitivity achieved by 5-ALA FD in different studies is generally very high, with values 87–97% (140), and 5ALA–mediated FD was shown to detect two times more tumors than standard white-light cystoscopy (141).”
BackgroundYu, J., Zhu, T., Wang, Z., Zhang, H., Qian, Z., Xu, H., Gao, B., Wang, W., Gu, L., Meng, J., et al. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-0861 · Cited by 207
Metadata
- Authors
- SCHNEEWEISS, S., KRIEGMAIR, M., & STEPP, H.
- Venue
- Journal of Urology
- Published
- 1999-04
- Volume
- 161
- Issue
- 4
- Pages
- 1116-1119
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W2043595825
- Cited by
- 51
- References
- 1
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.