Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 591

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

EFFECTS OF SILDENAFIL ON THE RELAXATION OF HUMAN CORPUS CAVERNOSUM TISSUE IN VITRO AND ON THE ACTIVITIES OF CYCLIC NUCLEOTIDE PHOSPHODIESTERASE ISOZYMES

BALLARD, STEPHEN A., GINGELL, CLIVE J., TANG, KIM, TURNER, LEIGH A., PRICE, MARY E., NAYLOR, ALASDAIR M.·1998·Journal of Urology

Abstract

PURPOSE: Sildenafil, an inhibitor of cGMP-specific phosphodiesterase 5 (PDE5), is currently undergoing evaluation as an oral therapy for penile erectile dysfunction. The aims of this study were to investigate the mechanism of action of sildenafil on the neurogenic relaxation of human corpus cavernosum (HCC) in vitro and to determine the activity of sildenafil against a full range of PDE isozymes. MATERIALS AND METHODS: Strips of HCC tissue were precontracted with phenylephrine. Relaxation responses resulting from electrical field stimulation (EFS) were then determined in the presence and absence of sildenafil. The effects of sildenafil on PDE1 to 5 prepared from human tissues and PDE6 from bovine retina were determined by measuring the conversion of [3H]-cGMP or [3H]-cAMP to their respective [3H]-5'-mononucleotides. RESULTS: Sildenafil (0.001 to 1 microM) enhanced the EFS-induced, nitric oxide (NO) dependent, relaxation of HCC in a concentration-dependent manner to a maximum of 3 times the pretreatment level at 1 microM sildenafil. Compared with zaprinast, an early PDE5 inhibitor, sildenafil was approximately 240-fold more potent, inhibiting PDE5 from HCC with a geometric mean IC50 of 3.5 nM. For sildenafil, IC50 values for inhibition of PDE1 to 4 were 80 to more than 8500 times greater than that for PDE5 and the IC50 for PDE6 (33 nM) was approximately 9-fold greater. CONCLUSIONS: The data support the proposal that enhancement of penile erection by sildenafil in patients with erectile dysfunction involves potentiation of the NO-stimulated cGMP signal mediating relaxation of cavernosal smooth muscle during sexual stimulation. Sildenafil is a potent inhibitor of PDE5 from HCC, with high selectivity for PDE5 relative to other PDE isozymes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-5347(01)63299-3

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
BALLARD, S. A., GINGELL, C. J., TANG, K., TURNER, L. A., PRICE, M. E., & NAYLOR, A. M.
Venue
Journal of Urology
Published
1998-06
Volume
159
Issue
6
Pages
2164-2171
ISSN
  • 0022-5347 (ISSN-L)
  • 1527-3792
OpenAlex
W2049472065
Cited by
591
References
1
FWCI
29.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.